Payment Terms | T/T, L/C, Western Union |
Supply Ability | 60000 pieces per month |
Delivery Time | 5-15 days after payment |
Packaging Details | export package / Negotiate |
Name | Lightning surge protector |
Poles Number | 2P |
Maximm continuous operating voltage | 255/275/320/385V |
Discharge current | 25KA |
CertificationCE,CQC | CE / CQC / SGS |
Connections | TT/TN |
Protection modes | L/N |
Brand Name | Uchi |
Model Number | OBV5-I-25 |
Certification | CE / SGS / ISO9001 |
Place of Origin | Dongguan China |
View Detail Information
Explore similar products
275VAC Power Surge Protection Device , Class 1 Surge Protection EN 61643-11
AC 100KA Power Surge Protection Device Low Voltage IEC61643-1
Single Phase AC Power Surge Protection Device 385V Limp 15KA
60KA Type 2 Power Surge Protection Device EN 61643-11
Product Specification
Payment Terms | T/T, L/C, Western Union | Supply Ability | 60000 pieces per month |
Delivery Time | 5-15 days after payment | Packaging Details | export package / Negotiate |
Name | Lightning surge protector | Poles Number | 2P |
Maximm continuous operating voltage | 255/275/320/385V | Discharge current | 25KA |
CertificationCE,CQC | CE / CQC / SGS | Connections | TT/TN |
Protection modes | L/N | Brand Name | Uchi |
Model Number | OBV5-I-25 | Certification | CE / SGS / ISO9001 |
Place of Origin | Dongguan China | ||
High Light | TN Outdoor Ethernet Cable Lightning Protection ,TN Type 1 2 Surge Protector ,320V Type 1 2 Surge Protector |
255/275/320/385V TT/TN Type 1+2 Surge Protector For lightning Protection
OBV5-I-25
OBV10-I-25 meet the type 1 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions.The voltage-limiting,high-performance spark gaps provide several benefits.A short response time, a low protection level and high current leakage capability with long service life.
Technical Parameters
Model: OBV10-I-25-Pluggable | |||
Maximum continuous operating voltage | Uc | V | 255/275/320/385 |
SPD to EN 61643-11 | Type 1+2 | ||
SPD to IEC 61643-1 | class I+2 | ||
LPZ | 0→2 | ||
Lightning impulse current (10/350μs) | Iimp | kA | 25 |
Lightning impulse current (10/350μs) [total] | kA | 100 | |
Nominal discharge surge current (8/20μs) | In | kA | 25 |
Arrester surge current (8/20μs) [total] | kA | 100 | |
Voltage protection level | Up | kV | 2,0 |
Response time | tA | ns | <100 |
Follow current quenching capacity Ipeak | Ifi peak | kA | 25 |
Maximum back-up fuse | A | 315 | |
Temperature range | ϑ | °C | -40℃~+85℃ |
Protection rating | IP 20 | ||
Connection cross-section, rigid | mm² | 10-50 | |
Connection cross-section, multi-wire | mm² | 10-35 | |
Connection cross-section, flexible | mm² | 10-25 |
Feature&Benefits
1,Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage.
2,Protect transmission of Ethernet signals with 48V DC / 34V AC power supply circuits against
lightning induced surges.
3,Enhanced surge protection.
4,For mounting on 35mm DIN rails acc. to EN 60715.
5,It can effectively ensure the equipments work properly.
·Easy installation or retrofit.
·Din-rail mountable.
·Fail-safe /self-protected designRemote indicator (optional) with 3pin NO/NC contact.
·IP20 finger-safe designVisual indicator.
·Small foot print.
Application
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
Note: The difference between T1 type and T2 type surge protector
The T1 type surge protector refers to the product with the lightning test waveform of 10/350us, and the T2 type surge protector refers to the product with the lightning test waveform of 8/20us.
The main difference between the two types of surge protectors lies in the different test waveforms. The energy of the 10/350us waveform is stronger than the energy of the 8/20us waveform, so in many cases the T1 surge protector is generally 12.5kA, 15kA, 25kA, etc. , T2 surge protector does have 20kA, 40kA, 60KA, 100kA, etc. Although the value of T2 type surge protector looks larger, their test waveforms are different. In fact, the energy of T1 is stronger.
Therefore, the national standard GB50057-2010 requires the installation of a T1 type surge protector in the main incoming line, which is also the first-level surge protector. When selecting the type, pay attention to the surge protector must have a T1 test Iimp (10/350us) test This parameter is generally Iimp is greater than or equal to 12.5kA, and the protection level Up≤2.5kV is enough.
Others
Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):
Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) |
Max Discharge Current |
Protection Level(KA~) | Response Time(ns) |
DGM1(2)-D5 | 220/380 |
275/320 |
5 | 10 | 1.2 | ≤25 |
DGM1(2)-D10 | 10 | 2 | 1.6 | |||
DGM1(2)-C20 | 20 | 40 | 1.8 | |||
DGM13-B30 | 30 | 60 | .2.2 | |||
DGM3(4)-B40 | 10 | 80 | 2.4 | |||
DGM(4)-B60 | 60 | 100 | 2.8 | |||
DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
Tip: Lightning protection is probabilistic protection, and we cannot provide 100% protection.
First, lightning discharge itself has a certain degree of randomness, and lightning parameters have certain statistical properties, which determines that all protective measures based on these statistical characteristics of lightning parameters cannot provide 100% protection. Such as: direct lightning protection-shielding characteristics; lightning current amplitude, waveform, etc. have statistical properties;
Second, the lightning protection equipment cannot prevent the formation of lightning flashes;
Third, lightning protection devices cannot ideally eliminate all interference voltages/currents. The fundamental purpose of taking protective measures is to ensure that most of the energy caused by interference does not spread to the vulnerable parts of the device and the staff.
Finally, the cost of protection against high-level surges with a small probability of occurrence has risen sharply.
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2006
Total Annual:
1,500,000-2,500,000
Employee Number:
138~168
Ecer Certification:
Verified Supplier
Uchi was established in 2006 in Dongguan, China. After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ... Uchi was established in 2006 in Dongguan, China. After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ...
Get in touch with us
Leave a Message, we will call you back quickly!