Payment Terms | T/T, L/C, Western Union |
Supply Ability | 60000 pieces per month |
Delivery Time | 5-15 days after payment |
Packaging Details | export package / Negotiate |
Un | 5V |
Rated discharge capacity | 5kA |
Working temperature | -40℃+80℃ |
Protect connector | RJ45 |
Response time | less than 1 ns |
CertificationCE,CQC | CE / CQC / SGS |
Uc | 8V |
In(8/20μs) | 5kA |
Up | 45V |
Vs | 1000M |
Brand Name | Uchi |
Model Number | RJ45 |
Certification | CE / SGS / ISO9001 |
Place of Origin | Dongguan China |
View Detail Information
Explore similar products
275VAC Power Surge Protection Device , Class 1 Surge Protection EN 61643-11
AC 100KA Power Surge Protection Device Low Voltage IEC61643-1
Single Phase AC Power Surge Protection Device 385V Limp 15KA
60KA Type 2 Power Surge Protection Device EN 61643-11
Product Specification
Payment Terms | T/T, L/C, Western Union | Supply Ability | 60000 pieces per month |
Delivery Time | 5-15 days after payment | Packaging Details | export package / Negotiate |
Un | 5V | Rated discharge capacity | 5kA |
Working temperature | -40℃+80℃ | Protect connector | RJ45 |
Response time | less than 1 ns | CertificationCE,CQC | CE / CQC / SGS |
Uc | 8V | In(8/20μs) | 5kA |
Up | 45V | Vs | 1000M |
Brand Name | Uchi | Model Number | RJ45 |
Certification | CE / SGS / ISO9001 | Place of Origin | Dongguan China |
High Light | DPR Surge Protector SPD ,Gigabit Ethernet Surge Protector SPD ,1000M Surge Protection Device SPD |
Protect conne | RJ45 | |||
Nominal voltage : Un | 5V | |||
Maximum continuous operating voltage: Uc | 8V | |||
Protection level at In (8/20μs): | 5V | |||
Response time: | <1ns | |||
Working temperature: | -40℃+80℃ | |||
SPD location: | Indoor | |||
Type of connection: | Series (two ports) | |||
narrative
This product is used for the protection of network signals. It is mainly used to suppress the induced lightning waves from the network signal line and the power system intrusion, so as to protect the electronic equipment from induced lightning strikes and static electricity damage.
Use environment
Temperature: -40℃~+80℃; Relative humidity: not more than 95% (25℃); Atmospheric pressure: 'not less than 74.8kpa
3. How it works
The lightning arrester is connected in series with the input end of the protected equipment. When the transmission line is induced by lightning to generate overvoltage, the lightning current is quickly released to the ground through the lightning branch of the lightning protection device, and the output voltage box of the lightning protection device is located in the equipment. within the withstand voltage range. So as to ensure the safe operation of the equipment.
5. Use and maintenance
5.1 Installation Instructions
5.1.1 Before the lightning arrester is connected to the system, first check the grounding resistance of the grounding grid, whether it meets the requirements of the specification, and should be ≤4Ω.
5.1.2 The lightning arrester is connected to the front end of the protected equipment, and the interface connection must be reliable.
5.1.3 Connect the grounding wire of the lightning arrester to the protective grounding busbar of the equipment room. The grounding wire should be as short and straight as possible, and the grounding length should not exceed 500mm.
5.2 Notes
5.2.1 There are input (IN) and output (OUT) marks on the surge arrester. The output terminal should be connected with the protected equipment, do not connect it in reverse. Otherwise, the lightning arrester will be damaged when lightning strikes, and the equipment will not be effectively protected.
5.2.2 Users are not allowed to disassemble the fasteners of various parts of the lightning arrester at will, so as to avoid damage, affect normal work, or even affect signal transmission or signal interruption
5.3 Inspection of the surge arrester 5.3.1 Use the three-meter "Ω×1" to measure the resistance between the input core wire and the output core wire of the surge arrester, which should be approximately zero; minecraft.
5.3.2 Use the three-meter "Ω×10k" gear to measure the resistance of the core wire to the mine ground and the shell to the mine ground, which should be infinite. If the measured resistance does not match the above, the lightning arrester should be replaced.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2006
Total Annual:
1,500,000-2,500,000
Employee Number:
138~168
Ecer Certification:
Verified Supplier
Uchi was established in 2006 in Dongguan, China. After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ... Uchi was established in 2006 in Dongguan, China. After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ...
Get in touch with us
Leave a Message, we will call you back quickly!