AC | 180V/320V |
Protection level Up | 1.5kV |
Nominal discharge current In(8/20μs) | 50kA |
Maximum discharge current Imax (8/20μs) | 50kA or 200kA |
Product Warranty | 1 Year |
Application | Solar Power System , industrial |
Brand Name | Uchi |
Model Number | Power lightning protection box |
Certification | CE / ISO9001 / FCC / SGS |
Place of Origin | Dongguan China |
View Detail Information
Explore similar products
275VAC Power Surge Protection Device , Class 1 Surge Protection EN 61643-11
AC 100KA Power Surge Protection Device Low Voltage IEC61643-1
Single Phase AC Power Surge Protection Device 385V Limp 15KA
60KA Type 2 Power Surge Protection Device EN 61643-11
Product Specification
Payment Terms | T/T, L/C | Supply Ability | 10000 pieces per month |
Delivery Time | 8 - 15 days after payment | Packaging Details | Export package |
AC | 180V/320V | Protection level Up | 1.5kV |
Nominal discharge current In(8/20μs) | 50kA | Maximum discharge current Imax (8/20μs) | 50kA or 200kA |
Product Warranty | 1 Year | Application | Solar Power System , industrial |
Brand Name | Uchi | Model Number | Power lightning protection box |
Certification | CE / ISO9001 / FCC / SGS | Place of Origin | Dongguan China |
High Light | AC 180V surge box protector ,200kA surge box protector ,350x260x130mm wire connection box |
Product Category(GB/IEC) | Class I+II/ Type 1+2 | |||
Protection mode | Full protection mode | |||
Product technologies | ESG technology (pre-stage) + VTD technology (post-stage); LC filter technology; thermal trip technology; built-in series overcurrent protection | |||
Applicable power distribution system | Un | 120/208V to 127/220V Three-phase (TN/TT) | 220/380V to 277/480V Three-phase (TN/TT) | |
Maximum sustainable working voltage (AC) | Uc | 180V | 320V | |
Rated load current | IL | 400A | ||
Nominal discharge current | In | 50kA (8/20μs) | ||
Pre-stage surge protection capability | L-N | Iimp: 50kA (10/350μs), Imax: 150kA (8/20μs) | ||
N-PE | Iimp: 100kA (10/350μs), Imax: 200kA (8/20μs) | |||
Post-level surge protection capability | L-N | Imax | 50kA (8/20μs) | |
Surge discharge capacity (each phase) | Imax | 200kA (8/20μs) | ||
Voltage protection level | L-N@6kV/3kA | VPR | ≤ 0.4kV | ≤ 0.5kV |
L-N@In(50kA, 8/20μs) | Up | ≤ 0.8kV | ≤ 1.0kV | |
N-PE@1.2/50μs | Up | ≤ 1.0kV | ≤ 1.5kV | |
Working current | IPE | <0.1mA | ||
Pressure drop | < 2V,At rated load current | |||
Temporary overvoltage characteristics-withstand mode | Utov | 230V/120min | 440V/120min |
Scope of application:
The second-level lightning protection box is mainly installed in the floor power distribution, computer room power distribution and other environments, as the second-level lightning protection of the power distribution system, discharges the remaining surge, and cooperates with the first-level lightning protection box to meet the lightning protection acceptance Requirements and protection needs.
The main parameters:
Maximum continuous working voltage Uc: 385VAC
Nominal discharge current In(8/20μs): 20kA or 40kA
Maximum discharge current Imax (8/20μs): 40kA or 80kA
Protection level Up: 1.8kV or 2.1kV
Protection mode: three-phase 4P, single-phase 2P
Product size: 350*260*130mm
Product Description:
Adopting Class II SPD to combine “3+1” circuit, protecting low voltage equipment from surge damages, applied in TT system, designed according to IEC61643-1/GB 18802.1
Main character:
1. Green light indicates normal and red light indicates fault for operation
2. Built-in circuit breaker, and thermal disconnection device, when the fault occurred, the thermal disconnection device will cut off the SPD from the power net, the green window will change
3. Impulse counter function, recording the lightning events
4. External wiring terminal, easy for connection, suitable for indoor application
Type | BT 5L CM 275/40 4P | BT 5L CM 385/40 4P | BT 5L CM 275/40 3+1 | BT 5L CM 385/40 3+1 | |
Order No. | 840 883 | 840 887 | 840 884 | 840 888 | |
Norminal a.c. voltage | UN | 230V/400V | 230V/400V | 230V/400V | 230V/400V |
Rated voltage (max. continuous a.c voltage) L/N | Uc | 275V | 385V | 275V | 385V |
Rated voltage (max. continuous a.c voltage) N/PE | Uc | 275V | 385V | 255V | 255V |
Nominal discharge current (8/20µs) L/N | In | 20KA | 20KA | 20KA | 20KA |
Nominal discharge current (8/20µs) N/PE | In | 20KA | 20KA | 40KA | 40KA |
Max. discharge current (8/20µs) L/N | Imax | 40KA | 40KA | 40KA | 40KA |
Max. discharge current (8/20µs) N/PE | Imax | 40KA | 40KA | 65KA | 65KA |
Voltage protection level L/N | Up | ≤1.25KV | ≤1.8KV | ≤1.25KV | ≤1.8KV |
Voltage protection level N/PE | Up | ≤1.25KV | ≤1.8KV | ≤1.5KV | ≤1.5KV |
Follow current extinguishing capability at Uc (N/E) | IL | 100Arms | 100Arms | ||
Operating temperature range | -40℃…+80℃ | ||||
Cross-sectional area | 25mm2 solid/35mm2 flexible | ||||
Enclosure material | black metal housing (die-casting Aluminum) | ||||
Test standards | YD/T 1235.1; GB 18802.1; IEC 61643-1 | ||||
Certification | CE (LVD, EMC) |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2006
Total Annual:
1,500,000-2,500,000
Employee Number:
138~168
Ecer Certification:
Verified Supplier
Uchi was established in 2006 in Dongguan, China. After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ... Uchi was established in 2006 in Dongguan, China. After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ...
Get in touch with us
Leave a Message, we will call you back quickly!