UnNominalworkingvoltage(Un) 1000V
UcMaxcontinuousoperatingvoltage(Uc) 1100VAC
Nominaldischargecurrent(kA) 20kA
Maxdischargecurrent(kA) 40kA
Protectionlevel(Up) 3.7kV
Response time(ns) 25ns
Installation 35mmslideguide
Workingconditions Temperature-40℃~+85℃;
Brand Name Uchi
Model Number OBV-SPD-420V
Certification CE / SGS / ISO9001
Place of Origin Dongguan China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C, Western Union Supply Ability 60000 pieces per month
Delivery Time 5-15 days after payment Packaging Details export package / Negotiate
UnNominalworkingvoltage(Un) 1000V UcMaxcontinuousoperatingvoltage(Uc) 1100VAC
Nominaldischargecurrent(kA) 20kA Maxdischargecurrent(kA) 40kA
Protectionlevel(Up) 3.7kV Response time(ns) 25ns
Installation 35mmslideguide Workingconditions Temperature-40℃~+85℃;
Brand Name Uchi Model Number OBV-SPD-420V
Certification CE / SGS / ISO9001 Place of Origin Dongguan China
High Light 40kA Surge Protector Breaker1000V Surge Protector Circuit BreakerISO9001 Surge Protector Breaker

unNominal working voltage (Un)1000V surge protector breaker
Model and specification  AM40-1000

Model AM40-1000
MainTechnicalData  
UnNominalworkingvoltage(Un) 1000V
UcMaxcontinuousoperatingvoltage(Uc) 1100VAC
 
   
Nominaldischargecurrent(kA) 20kA
Maxdischargecurrent(kA) 40kA
ProtectedMode + - PE,-- PE
Protectionlevel(Up) 3.7kV
Recommendmaxbackupfuse 63A(gL/gG)
Responsetime ≤25ns
Work/Faultindication Localindicatewindow:
Green=SPDOK|White=SPDFailure
Module 3
MechanicalSpecification  
InstallationLocation Indoor
Installation 35mmslideguide
Dimension(mm) 95*72*65
Cross-sectionalareamax ≥25mm2
Cross-sectionalareamin L/N:2.5mm2,PE:6mm2
Modeofconnection Connectioninparallel
EnvironmentSpecification  
Workingconditions Temperature-40~+85;
Relativehumidity≤95%;Height≤3km
ProtectionLevel IP20
Enclosurematerial ThermoplasticmaterialUL94V-0


 
Safety precautions:
· When the SPDboxis installed in final system,it must achieve all therequirements of GB4943 (EN60950,IEC60950) standard;
· The equipment has to be installed by authorized professional person, before installation, to cut offpowersupply,and prohibit hot-line work from accidents
 Application: ·
· AM type DC photovoltaic series power SPD is often used to prevent over-voltage from damaging DC power system and equipments, especiallyinsolar photovoltaic system.


Features:
· Temperature control circuit break technology, built-in over-current protection circuit,to completelykeep away from firedisaster · International famous components and advanced manufacturing technique · Big discharger current capacity,low residual voltage · Remote alarm connect point (optional)· Clear and intuifive working condifion · Easyinstallationandmaintain · Exquisite process,can work under the hostile environment for a long time,like acid,alkali,dust,salt fog,wet,etc

 

Structure &Shape


Installation:
· 35mm slide guide installation way

· Connect +/-and ground terminal of power systemto+/-and ground terminalof SPD, then screw up the bolts

· ground line of SPDto lightning protection systemground device

· After wiring.please checkituntil everything isgoingwell, toput into operation.
 

Product maintenance:
·The eauipment has to be installed byauthorized professional person, before installation,to cut off power supply,and prohibit hot-line work from accidents

· The sectional area of wire must reach technicaldemands

· When the SPD box is installed in final system,it must achieve all the requirements of GB4943 (EN60950,IEC60950)standard;

 

· Once there is afailure during systemoperation,please removethe SPD device at first,if the systemcan operate normally,the deviceis broken
 
Product standard
· GB18802.1low-voltage distributionsystemSP:performance demand and test method;

· YD/T 1235.1 Communication Station low-voltage power system SPD technical requirement;

·YD/T 1235.2 Communication Station low-voltage power system SPD test method;

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2006

  • Total Annual:

    1,500,000-2,500,000

  • Employee Number:

    138~168

  • Ecer Certification:

    Verified Supplier

Uchi was established in 2006 in Dongguan, China.  After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ... Uchi was established in 2006 in Dongguan, China.  After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ...

+ Read More

Get in touch with us

  • Reach Us
  • Guangdong Uchi Electronics Co.,Ltd
  • Room 810, Unit 2, Building 5, Huixing Commercial Center, Dongsheng Road No.1, Zhongshan Dong, Shilong Town Dongguan, GUANGDONG, 523326 CN
  • https://www.uchidg.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement