Payment Terms | T/T, L/C, Western Union |
Supply Ability | 100000pieces/year |
Delivery Time | within 15days |
Packaging Details | Standard export package |
Refrigerant | R22/R134a/R407C/R410A |
Product | Evaporator, Condenser |
Tyoe | Shell and tube type |
Cooling capacity | 18KW~3000KW |
Application | Cooling industry |
Shell material | seamless/304,316Lstainless steel pipe |
Brand Name | GREEFOUN |
Model Number | QXU125S10 |
Certification | CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Air Cooled Water Chiller Tubular Heat Exchanger Dry Type Sprial Baffle Plate
R404a Shell And Tube Heat Exchanger
Refrigerating Unit Flooded Heat Exchanger R134a Stainless Steel Tube Air To Air
Air Conditioning Unit Tube and Shell Heat Exchanger Condensing Pipe
Product Specification
Payment Terms | T/T, L/C, Western Union | Supply Ability | 100000pieces/year |
Delivery Time | within 15days | Packaging Details | Standard export package |
Refrigerant | R22/R134a/R407C/R410A | Product | Evaporator, Condenser |
Tyoe | Shell and tube type | Cooling capacity | 18KW~3000KW |
Application | Cooling industry | Shell material | seamless/304,316Lstainless steel pipe |
Brand Name | GREEFOUN | Model Number | QXU125S10 |
Certification | CE | Place of Origin | CHINA |
High Light | water to water heat exchanger ,shell and tube exchanger |
Straight Tube Baffle Plate Water - Cooled
Shell and Tube Heat Exchanger
A group of tubes or coils are housed in a housing consisting of heat exchangers. The heat transfer of the
two media, one in the tube, the other in the tube shell, through the wall of heat transfer, usually horizontal.
The capacity and heat exchange area of the new condenser are calculated as follows: Heat exchange
area (m2 = 3.1416 × tube diameter × tube length × total number of tubes. The size of the new condenser
should be selected according to the amount of medium to be condensed per unit time Size to set.
The use of tube bundle to make the cooling medium flow rate is better, so more energy efficient
(1) the design of the program: the given or selected process, the main equipment of the type of brief
discussion.
(2) the process design calculation (including computer aided calculation) of the main equipment: material
balance, energy measurement, process parameter selection, equipment structure design and process
size design calculation.
(3) the selection of auxiliary equipment: the typical auxiliary equipment, the calculation of the main process
size, equipment specifications, model selection.
(4) process flow chart: the form of a single-line drawing, marked the main equipment and auxiliary
equipment, material direction, logistics, energy flow, the main
To measure the point.
(5) the technical conditions of the main equipment diagram: the surface should include the equipment of
the main process size, technical characteristics of the table and take over the table.
STRAIGHT SINGLE SERIES DRY SPIRAL BAFFLE PLATE EVAPORATOR
CAPACITY: 310KW TO 680KW
Models | RE310S10 | RE360S12 | RE420S12 | RE470S12 | RE540S14 | RE620S14 | RE680S14 | ||
Rated data Refrigerant R22 ti=12°C te=2°C tu=7°C Dts=5°C | Qn | KW | 310 | 360 | 420 | 470 | 540 | 620 | 680 |
Kcal/h(×103 ) | 267 | 317 | 361 | 404 | 464 | 533 | 585 | ||
Wn | m3 /h | 53.3 | 62 | 72.2 | 80.8 | 93 | 107 | 116 | |
Wm | m3 /h | 68 | 70 | 81.7 | 100 | 105 | 140 | 145 | |
Dpn | bar | 0.43 | 0.43 | 0.35 | 0.46 | 0.41 | 0.47 | 0.49 |
Models | RE310S10 | RE360S12 | RE420S12 | RE470S12 | RE540S14 | RE620S14 | RE680S14 | |
Dimension(mm) | A | 140 | 140 | 150 | 150 | 150 | 170 | 170 |
B | 273 | 273 | 325 | 325 | 355 | 377 | 377 | |
C | 2500 | 1690 | 2400 | 1500 | 2690 | 2690 | 2860 | |
D | 360 | 360 | 406 | 406 | 440 | 460 | 460 | |
E | 370 | 370 | 380 | 380 | 400 | 400 | 400 | |
F | 2586 | 2586 | 2488 | 2586 | 2776 | 2776 | 2946 | |
Vent | S1 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Outlet | S2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Connection | W(DN) | 100 | 100 | 125 | 125 | 125 | 150 | 150 |
D1(mm) | 35 | 35 | 42 | 42 | 42 | 42 | 42 | |
D2(mm) | 67 | 67 | 80 | 80 | 90 | 90 | 90 | |
P(kg) | 296 | 380 | 398 | 442 | 459 | 654 | 669 | |
Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow Dpn-pressure drop of recirculating cooling water Dts-overheat temperature |
STRAIGHT SINGLE SERIES DRY SPIRAL BAFFLE PLATE EVAPORATOR (DOUBLE SYSTEM)
CAPACITY: 320KW TO 680KW
Models | RE320D10 | RE360D12 | RE420D12 | RE470D12 | RE540D14 | RE620D14 | RE680D14 | ||
Rated data Refrigerant R22 ti=12°C te=2°C tu=7°C Dts=5°C | Qn | KW | 320 | 360 | 420 | 470 | 540 | 620 | 680 |
Kcal/h(×103 ) | 267 | 317 | 361 | 404 | 464 | 533 | 585 | ||
Wn | m3 /h | 53.3 | 62 | 72.2 | 80.8 | 93 | 107 | 116 | |
Wm | m3 /h | 68 | 70 | 81.7 | 100 | 105 | 140 | 145 | |
Dpn | bar | 0.43 | 0.43 | 0.35 | 0.46 | 0.41 | 0.47 | 0.49 |
Models | RE320D10 | RE360D12 | RE420D12 | RE470D12 | RE540D14 | RE620D14 | RE680D14 | |
Dimension(mm) | A | 140 | 140 | 150 | 150 | 150 | 170 | 170 |
B | 273 | 273 | 325 | 325 | 355 | 377 | 377 | |
C | 2500 | 1690 | 2400 | 1500 | 2690 | 2690 | 2860 | |
D | 360 | 360 | 406 | 406 | 440 | 460 | 460 | |
E | 370 | 370 | 380 | 380 | 400 | 400 | 400 | |
F | 2586 | 2586 | 2488 | 2586 | 2776 | 2776 | 2946 | |
Vent | S1 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Outlet | S2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Connection | W(DN) | 100 | 100 | 125 | 125 | 125 | 150 | 150 |
D1(mm) | 35 | 35 | 42 | 42 | 42 | 42 | 42 | |
D2(mm) | 67 | 67 | 80 | 80 | 90 | 90 | 90 | |
P(kg) | 296 | 380 | 398 | 442 | 459 | 654 | 669 | |
Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow Dpn-pressure drop of recirculating cooling water Dts-overheat temperature |
CONDENSER SERIES SINGLE CIRCUIT
CAPACITY: 40RT TO 60RT
Model | Refrig. ton (RT) | Refrig. ton (104kcal/h) | Dimension (mm) | Weight (kg) | Max. water flow | |||||
D | T1 | T | A | C | E | |||||
QXC40S10 | 40 | 15.12 | 273 | 1600 | 1750 | 120 | 273 | 85 | 172 | 31 |
QXC45S10 | 45 | 17.01 | 273 | 1600 | 1750 | 120 | 273 | 85 | 180 | 35 |
QXC50S10 | 50 | 18.90 | 273 | 2032 | 2182 | 120 | 273 | 85 | 209 | 38.5 |
QXC55S10 | 55 | 20.79 | 273 | 2032 | 2182 | 120 | 273 | 85 | 217 | 42.5 |
QXC60S10 | 60 | 22.68 | 273 | 2032 | 2182 | 120 | 273 | 85 | 224 | 46 |
Model | S (Vent) | P (fluoride inlet) Copper pipe diameter (inch) | L(fluoride outlet) Copper pipe diameter (inch) | W (standard port) | W (optional port) |
FPT(inner pipe thread) | FPT(inner pipe thread) | FPT(inner pipe thread) | |||
QXC40S10 | 3/8 | 1-5/8 | 1-1/8 | 3 | 2-1/2 |
QXC45S10 | 3/8 | 1-5/8 | 1-1/8 | 3 | 2-1/2 |
QXC50S10 | 3/8 | 1-5/8 | 1-1/8 | 3 | 2-1/2 |
QXC55S10 | 3/8 | 1-5/8 | 1-3/8 | 3 | 2-1/2 |
QXC60S10 | 3/8 | 1-5/8 | 1-3/8 | 3 | 2-1/2 |
COOPERATED CLENTS
Company Details
Business Type:
Manufacturer
Year Established:
2003
Total Annual:
14,000,000.00-15,000,000.00
Employee Number:
150~200
Ecer Certification:
Active Member
WUHAN QIAOXIN REFRIGERATION EQUIPMENT CO., LTD. was founded in 2003, located in Wuhan Hubei province, which is a professional manufacturing enterprise dedicated to R&D, design, production and marketing of shell and tube condenser, evaporator and heat exchanger products ... WUHAN QIAOXIN REFRIGERATION EQUIPMENT CO., LTD. was founded in 2003, located in Wuhan Hubei province, which is a professional manufacturing enterprise dedicated to R&D, design, production and marketing of shell and tube condenser, evaporator and heat exchanger products ...
Get in touch with us
Leave a Message, we will call you back quickly!