Payment Terms | T/T, L/C, Western Union |
Supply Ability | 100000pieces per year |
Delivery Time | within 15days |
Packaging Details | Standard export package |
Cooling capacity | 18KW~4000KW |
Refrigerant | R404a |
Refrigerating medium | Water,vapor |
Shell material | Carbon steel |
Application | Chiller industry |
Product | Evaporator / Condenser |
Brand Name | GREEFOUN |
Model Number | QX-1200D |
Certification | CE,ISO9001:2008 |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Full Liquid Type R22 Water Cooled Evaporator Flooded Heat Exchanger
Chiller Water Cooled Full Liquid Type Heat Exchanger Vapour Condenser
R22 Flooded Heat Exchanger
High Temperature Chiller Heat Exchanger , Shell And Tube Condenser 18KW-4000KW
Product Specification
Payment Terms | T/T, L/C, Western Union | Supply Ability | 100000pieces per year |
Delivery Time | within 15days | Packaging Details | Standard export package |
Cooling capacity | 18KW~4000KW | Refrigerant | R404a |
Refrigerating medium | Water,vapor | Shell material | Carbon steel |
Application | Chiller industry | Product | Evaporator / Condenser |
Brand Name | GREEFOUN | Model Number | QX-1200D |
Certification | CE,ISO9001:2008 | Place of Origin | CHINA |
High Light | flooded type evaporator ,tube shell heat exchanger ,R404A Flooded Type Evaporator |
Double Circuit R404A Flooded Type Evaporator External Oil Separator
Double Circuit R404A Flooded Type Evaporator External Oil Separator
In full - liquid evaporator, the liquid refrigerant enters the evaporator through throttling device, and the liquid level in the evaporator remains constant. The heat transfer tube in the evaporator is immersed in the refrigerant liquid. There is still a large amount of liquid in the gas liquid mixture after evaporation, so the vapor from the evaporator is separated and then returned to the compressor. Dry evaporator is controlled directly by thermal expansion valve or electronic expansion valve the liquid refrigerant entering the evaporator tube side, the refrigerant liquid in the pipe completely transformed into gas, electrical and mechanical is cooling medium flow in tube side outside the pipe. The evaporator evaporator's evaporator surface is liquid wet, Surface heat transfer coefficient is greater than the surface heat transfer coefficient of dry evaporator.
Flooded Type Evaporator Condenser (External Oil Separator) Double Circuit
(Capacity) 800KW TO 4000KW
Models | QX-800D | QX-1600D | QX-2200D | QX-2900D | QX-3500D | QX-4000D | ||
R22 (or other environmental refrigerants) | Refrigerating capacity (KW) | 800 | 1600 | 2200 | 2900 | 3500 | 4000 | |
Heating capacity (KW) | 950 | 2000 | 2650 | 3750 | 4000 | 4500 | ||
Wa | m3/h | 138 | 276 | 379 | 499.6 | 602.3 | 688.5 | |
Wb | m3/h | 192 | 344 | 473 | 624 | 700 | 773 | |
Dpn | bar | 0.71 | 0.79 | 0.84 | 0.87 | 0.79 | 0.84 | |
Size(mm) | A | 3909 | 4245 | 4245 | 4845 | 5035 | 5035 | |
A1 | 450 | 500 | 500 | 550 | 550 | 600 | ||
A2 | 360 | 400 | 400 | 450 | 450 | 500 | ||
L1 | 2032 | 2200 | 2200 | 2500 | 2690 | 2690 | ||
B | 1340 | 1470 | 1570 | 1670 | 1670 | 1670 | ||
B1 | 690 | 755 | 805 | 855 | 855 | 905 | ||
C1 | 925 | 1008 | 1058 | 1108 | 1108 | 1158 | ||
C2 | 925 | 1008 | 1058 | 1108 | 1108 | 1158 | ||
D1 | 426 | 480 | 530 | 616 | 616 | 666 | ||
D2 | 480 | 566 | 616 | 666 | 666 | 766 | ||
H1 | 300 | 350 | 350 | 420 | 500 | 550 | ||
H2 | 260 | 280 | 350 | 420 | 500 | 550 | ||
Inlet/Outlet Size | a/b(DN) | 150 | 200 | 200 | 250 | 250 | 300 | |
c1-2(mm) | 35 | 42 | 42 | 54 | 54 | 54 | ||
d1(mm) | 92 | 92 | 105 | 105 | 105 | 105 | ||
d2(mm) | 67 | 80 | 80 | 92 | 92 | 92 | ||
Oil Separator | Liter | 90*2 | 130*2 | 180*2 | 220*2 | 250*2 | 300*2 | |
Weight | kg | 1745 | 3140 | 3610 | 4610 | 5550 | 6900 | |
Notes: Wa Evaporator Water Flow Wb Condenser Water Flow Dpn Circulating Cooling Water Pressure Drop
Refrigerating condition: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C Heating condition: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C. |
COOPERATED CLENTS
Company Details
Business Type:
Manufacturer
Year Established:
2003
Total Annual:
14,000,000.00-15,000,000.00
Employee Number:
150~200
Ecer Certification:
Active Member
WUHAN QIAOXIN REFRIGERATION EQUIPMENT CO., LTD. was founded in 2003, located in Wuhan Hubei province, which is a professional manufacturing enterprise dedicated to R&D, design, production and marketing of shell and tube condenser, evaporator and heat exchanger products ... WUHAN QIAOXIN REFRIGERATION EQUIPMENT CO., LTD. was founded in 2003, located in Wuhan Hubei province, which is a professional manufacturing enterprise dedicated to R&D, design, production and marketing of shell and tube condenser, evaporator and heat exchanger products ...
Get in touch with us