Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"300A Standard Current Transformer CT PT Testing Equipment For Instrument","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/14\/6e\/4b5108174e476f0cac1d5f1e0c50-200x200-1\/300a_standard_current_transformer_ct_pt_testing_equipment_for_instrument.jpg","attrs":{"Brand Name":"RISING","Model Number":"RSHL-200A","Certification":"ISO CE","Place of Origin":"China"}}
{"title":"RSQY-C Secondary Load Tester Instrument -10\u2103-40\u2103 Temperature Humidity \u226485%","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/d7\/4e\/89c2ef258a5639408b3625919df6-200x200-1\/rsqy_c_secondary_load_tester_instrument_10_e2_84_83_40_e2_84_83_temperature_humidity_e2_89_a485_25.jpg","attrs":{"Brand Name":"RISING","Model Number":"RSQY-C","Certification":"ISO CE","Place of Origin":"China"}}
{"title":"RSQY-C CT PT Testing Equipment Secondary Voltage Drop Tester Instrument","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/02\/ae\/09cae49118f002bcf3e157438312-200x200-1\/rsqy_c_ct_pt_testing_equipment_secondary_voltage_drop_tester_instrument.jpg","attrs":{"Brand Name":"RISING","Model Number":"RSQY-C","Certification":"ISO CE","Place of Origin":"China"}}
{"title":"RSOVT Open Circuit Voltage Tester Input impedance >10M\u03a9 Humidity <80\u2105","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/26\/94\/571f3aed9cb3bb44ba7cca7fedde-200x200-1\/rsovt_open_circuit_voltage_tester_input_impedance_3e10m_ce_a9_humidity_3c80_e2_84_85.jpg","attrs":{"Brand Name":"RISING","Model Number":"RSOVT","Certification":"ISO CE","Place of Origin":"China"}}
{"title":"RS205-L CT PT Testing Equipment Current Transformer Error Tester on Site","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/a2\/8d\/104d256dee17f2805a4f29a29882-200x200-1\/rs205_l_ct_pt_testing_equipment_current_transformer_error_tester_on_site.jpg","attrs":{"Brand Name":"RISING","Model Number":"RS205-L","Certification":"ISO CE","Place of Origin":"China"}}
{"title":"Rs025-Y Voltage Transformer Error Tester Large Screen Lcd Displa","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/a2\/8d\/104d256dee17f2805a4f29a29882-200x200-1\/rs025_y_voltage_transformer_error_tester_large_screen_lcd_displa.jpg","attrs":{"Brand Name":"RISING","Model Number":"RS025-Y","Certification":"ISO CE","Place of Origin":"China"}}
{"title":"RSHL-200A CT PT Testing Equipment High Accuracy Standard Current Transformer","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/6c\/e5\/cf1f30931db06a9fbb3ac536f951-200x200-1\/rshl_200a_ct_pt_testing_equipment_high_accuracy_standard_current_transformer.jpg","attrs":{"Brand Name":"RISING","Model Number":"RSHL-200A","Certification":"ISO CE","Place of Origin":"China"}}
RSHL-300A CT PT Testing Equipment High Accuracy 0.05 class 300A Standard Current Transformer
Product Description
Purpose
It can be used as a standard instrument for the verification of grade current transformers or for other precision current measurement
Conditions of use
Ambient temperature:0°C -- +40°C; Relative humidity should be greater than 80%
Use and maintenance
Please be careful not to seriously collide with the machine due to its epoxy resin casting.The machine should be moisture-proof and soiled.And the surface of the instrument should be wiped with a clean cloth before the test to prevent creepage along the surface
In the process of measuring the current,do not allow sudden interruption in the current,so easy to cause remanence in the iron core,easy to cause a large error in the measurement.
Special attention should be paid to the fact that in the process of measurement,the secondary coil loop should be firmly grounded,and no open circuit should be opened to avoid the generation of high voltage,so as not to harm people.
Current (A)
Primary connection method
Secondary connection method
300
L1 L2
K1 K6
200
L1 L2
K1 K4
100
L1 L2
K1 K3
50
L1 L2
K1 K2
25
L1 L3
K1 K5
10
L1 L3
K1 K3
5
L1 L3
K1 K2
Technical Parameters
Primary and secondary current ratio:5,10,25,50,100,200,300/5A
Rated frequency:50Hz
Power factor:1.0
Rated load:5VA
Accuracy level:0.05 Class
Rated working voltage:5/kV
Power frequency withstand voltage test:one to two and to the ground 10kV/1min, two to the ground 2kV/1min.
Note:At the time of delivery,the rated power frequency withstand voltage test value(10kV)has been tested.After delivery,80% of the rated value should be tested according to the regulations.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Ecer Certification:
Active Member
Wuhan Rising Electric Co., Ltd. established in 2 0 0 6,located in the National High-tech Development zone - Wuhan East Lake Development zone.We are a high-tech enterprises which take high-voltage test equipments and related instrumentation’s research, development, production and management as ... Wuhan Rising Electric Co., Ltd. established in 2 0 0 6,located in the National High-tech Development zone - Wuhan East Lake Development zone.We are a high-tech enterprises which take high-voltage test equipments and related instrumentation’s research, development, production and management as ...