Payment Terms | T/T, Western Union, MoneyGram,L/C, D/A, D/P, |
Supply Ability | 100 SET PER Month |
Delivery Time | 20 working days |
Packaging Details | Wooden package for export |
Voltage | 0.1-600V |
Current | 0.1-200A |
Power | U*I |
Power factor | 0.1-0.9999 |
Power supply | AC220V±10% 50Hz±2% |
Working temperature | 0-40℃ |
Relative humidity | 30%-90% |
Outline dimension | Customization |
Brand Name | RISING |
Model Number | RSBTT III |
Certification | ISO CE |
Place of Origin | China |
View Detail Information
Explore similar products
Touch Screen Transformer Testing Equipment AC380V±10% Power Supply
Full Automatic Transformer Test Bench / Frequency Withstand Voltage Test Panel
Full Automatic Transformer Testing Equipment 0.1V - 800V Voltage
CT PT Test Transformer Test Bench Integrated System , Transformer Test System
Product Specification
Payment Terms | T/T, Western Union, MoneyGram,L/C, D/A, D/P, | Supply Ability | 100 SET PER Month |
Delivery Time | 20 working days | Packaging Details | Wooden package for export |
Voltage | 0.1-600V | Current | 0.1-200A |
Power | U*I | Power factor | 0.1-0.9999 |
Power supply | AC220V±10% 50Hz±2% | Working temperature | 0-40℃ |
Relative humidity | 30%-90% | Outline dimension | Customization |
Brand Name | RISING | Model Number | RSBTT III |
Certification | ISO CE | Place of Origin | China |
High Light | transformer test machine ,transformer test device |
Automatic Comprehensive Transformer Testing Equipment for Laboratory or Workshop
RSBTT is according with the relevant standards such as IEC 60076, IEC 61558-1 and so on.
The measuring device is controlled by the high-grade single chip microcomputer (SCM), with the digital display, the no load, short circuit and other test data synchronously also sampled by the SCM.
It is avoid separately reading the voltmeter, ammeter and power meter in the traditional test methods and causing error due
to manual computation.
Item |
Equipment name |
Product model |
||
Part one:The main console body and an external device(automatic, manual)
|
||||
01 |
Automatic transformer characteristics test main console body |
RSBTT-Ⅲ | ||
100kVA Induction voltage regulator |
TSJA-100KVA/0-450V | |||
High-voltage measurement cabinet |
RSBTT-Ⅲ | |||
HV current transformer |
RSHL-200A/30kV | |||
HV voltage transformer |
RSHJ-30kV | |||
Part two:Power frequency withstand voltage test
|
||||
02 |
Oil immersed transformer AC test |
RSYDW-50kVA/100kV
|
||
Part three:Frequency multiplication withstand voltage test part
|
||||
03 |
Intermediate frequency generator set |
RSFJW-60kVA
|
||
04 |
Intermediate boost transformer |
100kVA/15KV/4KV/ 0.4kV |
Test ability:
1)Can meet the capacity of 63000KvA, 110Kv and below the oil-immersed transformer (including S9 S11 S13 and amorphous alloy transformer);
2) It can meet the capacity of 31500KvA, 35Kv and below dry-type transformers;
3) Mine explosion-proof transformers that can meet capacity of 6300KvA, 10Kv and below;
4) Special transformer (need to inform detailed capacity and voltage level when ordering).
Test item:
1) Transformer winding resistance test
2) Transformer voltage ratio measurement and connection group number test
3) Transformer no-load current (%) and no-load loss test
4) Transformer short circuit impedance (%) and load loss test
5) Transformer power frequency applied pressure test
6) Transformer induced withstand voltage test
Extensible test project:
1) Transformer partial discharge test
2) No-load harmonic test (0-31th harmonic)
3) Withstand voltage test of transformer oil (0-80Kv)
4) Transformer temperature rise test (can automatically draw temperature rise curve)
5) Insulation resistance test (absorption ratio and polarization index)
6) Transformer anti-interference dielectric loss test
7) Lightning impact test.
Performance indicators:
1. Tested transformer parameters
1.1 Transformer capacity under test (to meet temperature rise test condition, dry type transformer)
10kV level ≤2500KVA
35kV level ≤6300kVA
1.2 Tested transformer voltage level below 35kV on primary side
2. Accuracy
2.1 Voltage Range 0-22kV
2.2 Current Range 0-400A
2.3 Minimum voltage resolution 0.001V* PT ratio
2.4 Minimum current resolution 0.0001A*CT ratio
2.5 Power Minimum Resolution 0.1W*PT Ratio*CT Ratio
2.6 Ambient temperature -10~45°C
2.7 Using Relative Humidity 85%
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Ecer Certification:
Active Member
Wuhan Rising Electric Co., Ltd. established in 2 0 0 6,located in the National High-tech Development zone - Wuhan East Lake Development zone.We are a high-tech enterprises which take high-voltage test equipments and related instrumentation’s research, development, production and management as ... Wuhan Rising Electric Co., Ltd. established in 2 0 0 6,located in the National High-tech Development zone - Wuhan East Lake Development zone.We are a high-tech enterprises which take high-voltage test equipments and related instrumentation’s research, development, production and management as ...
Get in touch with us
Leave a Message, we will call you back quickly!