Payment Terms | L/C, T/T |
Supply Ability | 10000units/month |
Delivery Time | 7 working days |
Packaging Details | CARTONS/PLYWOOD CASE/PALLET |
Rated Voltage | 220V/110V |
Application | Solar Pump Station |
Model | PT-SP |
Pump | WILO |
Using | Centralized Solar Water Heating System |
Colour | Silver |
Pipe | Copper |
Accessories | Controller and Pump |
Brand Name | PASSION/OEM |
Model Number | PT-SP |
Certification | CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
SR609C Solar Water Heater Controller With Temperature Display SR1568
SR208C Solar Water Heater Controller Residential Split Pressure Control SR609C
SR288 Intelligent Solar Water Heater Controller for Split Pressurized Solar
ABS Housing Digital Solar Controller SR609C Water Proof Controller
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 10000units/month |
Delivery Time | 7 working days | Packaging Details | CARTONS/PLYWOOD CASE/PALLET |
Rated Voltage | 220V/110V | Application | Solar Pump Station |
Model | PT-SP | Pump | WILO |
Using | Centralized Solar Water Heating System | Colour | Silver |
Pipe | Copper | Accessories | Controller and Pump |
Brand Name | PASSION/OEM | Model Number | PT-SP |
Certification | CE | Place of Origin | CHINA |
High Light | solar hot water controller ,solar thermal controller |
Intelligent Controller for Centralized Hotel Resort Solar Water Heating Project
Main Functions:
1, Time display
2, Water temperature display
3, Water level display
4, Auto mode
5, Water level pre-setup
6, Manual water loading
7, Temperature controlled water loading
8, Timing water loading
9, Water loading when tank is lack of water
10, Compulsive water loading
11, Increasing Water pressure during water is loaded.
12, Manual heating
13, Timing heating
14, Hot water circulation
15, Hot water pipe insulation
16, Low pressure protection
17, Collector tube protection
18, Memory protection when power is failure
CENTRALIZED SOLAR WATER HEATING SYSTEM USER MANUAL
PART ONE
A. Water shortage protection.
If the ‘actual water level’ is less than(<) the ‘start the protection at water level’ ,
the centralized solar water heating system start the ‘water shortage protection’, all the related water pump,auxiliary heating stop the working.
If the ‘actual water level’ is greater than or equal to (≥) the ‘stop the protection of water level’ ,
the centralized solar water heating system stop the ‘water shortage protection’, all the related water pump,auxiliary heating restart the working.
B. Heat exchange(the circulation between the water tank and solar collector).
When the ‘temperature in difference ’ between the water tank and and the solar collector
is greater than or equal to (≥) the ‘start the circulation at’ , the circulation start the working.
When the ‘temperature in difference ’ between the water tank and and the solar collector
is less than or equal to (≤) the ‘stop the circulation at’ , the circulation stop the working.
Note:
When the ‘actual tank temperature’ is greater or equal to (≥) the setting value ‘Highest temp of water tank’,
the circulation pump will be forced to stop the working.
In case that the actual tank temperature will be too much higher.
C. Anti-freezing of collector pipeline
When the temperature in the collector pipeline is less than(<) the temp of ‘Start the pipeline circulation at’,
the circulation pump will be forced switch on for some time (It depends on the setting of ‘working time’).
Then it stop by 3 minutes, and detect the temperature in the collector pipeline for several times,
until the temperature in the collector pipeline is more than(>) the setting temperature.
D. Circulation of terminal water pipeline(between the water tank and terminal water using).
When the temperature of terminal pipeline is less than or equal to(≤) the setting temp ‘start the circulation at’,
it start the circulation.
When the temperature of terminal pipeline is greater than (>) the setting temp ‘stop the circulation at’,
it stop the circulation.
E. Anti-freezing of terminal water pipeline(between the water tank and terminal water using).
When the temperature of terminal pipeline is less than or equal to(≤) the setting temp ‘start the circulation at’,
it will be forced start the circulation for 5 minutes.
It can prevent the pipeline from frost crack.
F. Auxiliary heating.
When the water tank temperature is less than(<) the temp of ‘start the electric heating at’,
the electrical element start the working.
When the water tank temperature is more than(>) the temp of ‘start the electric heating at’,
the electrical element stop the working.
G. Automatically water supply.
When the ‘water level’ is less than or equal to(≤) the minimum water level ‘start the water supply at level’,
it start the water supply.
When the ‘water level’ is greater than (>) the maximum water level
‘stop the water supply at level’, it stop the water supply.
H. Reset.
Press the ’reset’ to restore the original factory system defaults.
Applications
1) Hotels, resorts, hospitals and hostels
2) Process industry, boiler feed, laundry and canteens
3) Agricultural sector, hatcheries and dairies
4) Process industry, Boiler feed, Laundry and canteens
5) Agricultural sector, hatcheries, and dairies
6) Swimming pool heating
7) In-process heating
8) Health clubs (Steam / Sauna)
Specifications
Modle | PT-NC-15 | PT-NC-20 | PT-NC-25 | PT-NC-30 | PT-NC-40 | PT-NC-50 | PT-NC-60 | |
Quantity of Tubes | 15 | 20 | 25 | 30 | 40 | 50 | 60 | |
Contour aperture area | 1.94m2 | 2.58m2 | 3.22m2 | 3.88m2 | 5.16m2 | 6.44m2 | 7.76m2 | |
Manifold | Inner shell: 304 2B | Foaming: High pressure polyurethane | ||||||
Three Target Vacuum Tube | Diameter/Length: φ58mm/1800mm; High boron and silicon content 3.3; Structure:Gradual change SS-AL-Nx/Cu selective absorption coating; Vacuum Degree:P<=5*10-3; | |||||||
Anti-dust Ring | White Silicon Rubber | |||||||
Work Pressure | 0.05Mpa | |||||||
Bracket | Galvanized Steel with Plastic Coating in Black color - 0/20/30/45 degrees | |||||||
Tailstock | ABS | |||||||
OEM Service | Logo painting on products and package is for free (20FT,40FT,40HQ) |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
1996
Total Annual:
3000000-5000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
JIAXING PASSION NEW ENERGY TECHNOLOGY CO., LTD. is a manufacturer of Solar Water Heater since 1996. As an experienced company, we can provide the perfect solution for Solar Thermal System. Our products include solar water heater, solar collector and accessories. We have advanced technolog... JIAXING PASSION NEW ENERGY TECHNOLOGY CO., LTD. is a manufacturer of Solar Water Heater since 1996. As an experienced company, we can provide the perfect solution for Solar Thermal System. Our products include solar water heater, solar collector and accessories. We have advanced technolog...
Get in touch with us
Leave a Message, we will call you back quickly!