Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 200 sets/month |
Delivery Time | 10-30 days |
Packaging Details | wooden packaging |
Product Name | Power Battery Squeeze Acupuncture Extrusion Testin |
Control Mode | PLC Human Touch Interface |
Maximum Testing Voltage | 0~100V |
Mechanical Life | 300K Times |
Warranty | 1year |
Standards | IEC62133-2017 |
Key Words | Battery Short Circuit Test Chamber |
Maximum Short Circuit Current | 500A/1000A/2000A/3000A/5000A/10000A |
Action Time | Response Time / Release Time |
Advantage | Factory Direct Sale |
Brand Name | GESTER |
Model Number | GT-I09 |
Certification | CE,ISO |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Compression Thermal Abuse Case Stress 380V Battery Test Chamber
80t Lithium Ion Safty Lab Nail Penetration Battery Testing Equipment
Overcharge And Overdischarge Explosionproof Battery Test Chamber
9.1kg Drop UN38.3 Heavy Battery Testing Equipment For Destructive Test
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 200 sets/month |
Delivery Time | 10-30 days | Packaging Details | wooden packaging |
Product Name | Power Battery Squeeze Acupuncture Extrusion Testin | Control Mode | PLC Human Touch Interface |
Maximum Testing Voltage | 0~100V | Mechanical Life | 300K Times |
Warranty | 1year | Standards | IEC62133-2017 |
Key Words | Battery Short Circuit Test Chamber | Maximum Short Circuit Current | 500A/1000A/2000A/3000A/5000A/10000A |
Action Time | Response Time / Release Time | Advantage | Factory Direct Sale |
Brand Name | GESTER | Model Number | GT-I09 |
Certification | CE,ISO | Place of Origin | CHINA |
High Light | 100V battery short circuit tester ,IEC62133-2017 battery short circuit tester ,IEC62133-2017 Battery External Short Circuit Test |
Battery External Short Circuit Testing Machine For Lithium Ion is designed according to the requirements of various battery short-circuit test standards. According to the standard, the short-circuit device must meet the internal resistance range of 80mΩ±20 or ≤10mΩ to obtain the maximum short-circuit current required by the test. This machine is used to simulate the external short circuit of the battery or battery pack/battery pack sample, and judge its safety through its phenomenon.
Standards
GB 31241-2014, UL 2540-2013, UL 1642, UL 2054, UN38.3, IEC62133-2017
Model | GT-I09 |
Impact voltage | AC 1kv/1.2-50μs(peak)1min |
Maximum testing voltage | 0~100V |
Dc response time | ≤5μs |
Maximum short circuit current | 500A/1000A/2000A/3000A/5000A/10000A |
The device interior resistance | 80±20mΩ OR ≤5mΩ OR < 20mΩ OR 30± 10mΩ |
Action time | Response time / release time |
Performance characteristic | Cold and voltage 66%Us Cold release voltage30%Us,5%Us |
Mechanical life | 300k times |
Test Chamber temperature Range | RT + 10~100 ºC |
Temperature control accuracy | 0.1ºC |
Temperature uniformity | ± 2 ºC |
Temperature fluctuation | ± 0.5 ºC |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Importer,Exporter,Trading Company,Seller
Year Established:
1997
Total Annual:
100-1000
Employee Number:
51~100
Ecer Certification:
Active Member
Gester Instruments Co.,LTD is professionally engaged in production and R&D of physical properties testing equipment. With more than 20 years experience in research and development,we specialize in providing the total solutions of Toys and Baby Stuff Testing Equipment, Te... Gester Instruments Co.,LTD is professionally engaged in production and R&D of physical properties testing equipment. With more than 20 years experience in research and development,we specialize in providing the total solutions of Toys and Baby Stuff Testing Equipment, Te...
Get in touch with us
Leave a Message, we will call you back quickly!