Payment Terms | L/C, T/T |
Supply Ability | 1000 Set / Sets per Month |
Delivery Time | 10-60days after confirmed payment or by contract stipulation |
Packaging Details | Export package |
Impulse Voltage | AC 1kv/1.2-50us (Peak) Lmin |
Voltage Resolution | 0.01V |
Rated test current | ≥10000A |
Maximum operating current duration | ≥10ms5.5. |
Voltage acquisition range | 0-1000v |
Temperature acquisition accuracy | ≤±1.5ºC |
Brand Name | GSKA |
Model Number | Battery Short-Circuit Test Chamber |
Certification | CE SGS ROHS UL CE |
Place of Origin | Dongguan China |
View Detail Information
Explore similar products
Three Slot Battery Discharge Overcharge Explosion Proof Test Chamber OEM
SUS304 Stainless Steel Battery Test Equipment Combustion Jet 380V
Laboratory Battery Testing Equipment , Heavy Weight Impact Testing Machine
Half Sine Wave Battery Test Equipment With Vibration Impact Test Bench
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 1000 Set / Sets per Month |
Delivery Time | 10-60days after confirmed payment or by contract stipulation | Packaging Details | Export package |
Impulse Voltage | AC 1kv/1.2-50us (Peak) Lmin | Voltage Resolution | 0.01V |
Rated test current | ≥10000A | Maximum operating current duration | ≥10ms5.5. |
Voltage acquisition range | 0-1000v | Temperature acquisition accuracy | ≤±1.5ºC |
Brand Name | GSKA | Model Number | Battery Short-Circuit Test Chamber |
Certification | CE SGS ROHS UL CE | Place of Origin | Dongguan China |
High Light | AC 1KV Short Circuit Tester ,10000A Short Circuit Tester ,SGS Lithium Battery Short Circuit Tester |
AC 1KV Impulse Voltage Short Circuit Tester For Lithium Battery
Product use:
The battery pack short-circuit equipment is mainly used for the safety verification test of power battery cells, monomers, modules, PACK-level battery packs and structural parts of new energy projects. Simulate the short-circuit situation of battery cells, cells, modules, and PACK-level battery packs during use, transportation and storage to evaluate the safety performance of batteries. Present the actual use of battery packs or systems in the laboratory, find and solve problems, optimize product design, and improve product quality
Product manual:
1. Application of battery pack short circuit equipment: It is mainly used for the safety verification test of power battery cells, monomers, modules, PACK and other battery packs and structural parts of new energy projects. Simulate the short-circuit situation of battery cells, monomers, modules and PACK battery packs during use, transportation and storage to evaluate the safety performance of the battery. Present the actual use of battery packs or systems in the laboratory, find and solve problems, optimize product design, and improve product quality.
2. The battery pack short-circuit equipment is composed of a short-circuit control box, a vacuum arc extinguishing device, a short-circuit terminal wiring, a data acquisition system and a computer for data analysis.
Overview of battery pack short-circuit equipment design:
The short-circuit equipment is designed based on the requirements of various battery short-circuit test standards, that is, it meets CB31467.31CB31485UU25801SAE J24641SAEJ2929UN38.3ECER100IEC6213UL1642 Qc / T 743 and "863i Plan" Energy-Saving and New Energy Vehicle Major Projects - 2008 EV Lithium-ion Power Battery Performance Test Specifications and other standards; short-circuit devices must meet the internal resistance range according to the standard <5m or >5m2&<10m or >10m2&<20m or >40m&<50m or >80m&100m2 to obtain the maximum short-circuit current of the test; the circuit design of the short-circuit device can also withstand the impact of a large current of 16000A, so we choose industrial grade mechanical suction
fulfill the standard:
1. CB31467.3 "Lithium-ion power battery packs and systems for electric vehicles No. 3: Safety requirements and test methods"
2.CB/T 31485-2015 "Safety Requirements and Test Methods for Power Batteries for Electric Vehicles"
QC/ T 743-2006 "Lithium-ion batteries for electric vehicles"
CB/T 18332-2015 "Zinc Air Batteries for Electric Vehicles"
5. Ji 2580-2013 "Electric Vehicle Battery Safety Standards"
6. SAND99-0497 "American Automotive Power Battery Test Standard"
7. SAE J2464 "Electric and Hybrid Electric Vehicle Charging and Energy Storage Safety and Abuse Test"
8. SAE J2929-2013 "Safety Standard for Electric and Hybrid Vehicle Propulsion Battery Systems." Lithium-based rechargeable battery" and
other test standards
technical parameter |
|
Impulse voltage | AC 1kv/1.2-50us (peak) lmin |
Action characteristics | Cold state pull-in voltage 66%Us |
Cold release voltage bucket 30%Us,*5%Us | |
Action time | Pull-in time/release time: 20ms |
Maximum operating current duration | ≥10ms5.5. |
Voltage acquisition range | 0-1000v |
Voltage resolution | 0.01v |
Voltage measurement accuracy | ±0.5% (full scale) |
Voltage set channel | Standard 1 channel, isolated between channels, can support expansion |
Rated test current | ≥10000A |
Maximum operating current | ≥15000A |
Maximum pulse current | ≥16000A |
Current acquisition range | 0-15000A |
Current measurement accuracy | 1000A-15000A, the accuracy is ±0.5% |
Current resolution | 0.1A |
Current acquisition channel | Standard 1 channel, isolated between channels, can support expansion |
Temperature acquisition range | -200-1350ºC |
Temperature acquisition accuracy | ≤±1.5ºC |
temperature acquisition channel | Standard 12 channels, isolated between channels, can support expansion |
Data collection frequency | 7.19.1.10mslhr, 19 kinds can be set (if the test channel is more than |
7.19.2. Due to the high frequency of data collection, the data read and | |
Runtime recording accuracy | ≤±0.1% (full scale) |
Test Data | The voltage/current/temperature data is displayed and recorded on the control |
way to control | Using remote touch screen control + remote control + computer (for data |
short circuit | Mechanical pull-in (contactor pneumatic pull-in, synchronous forced disconnection |
Short circuit cut-off condition | Short circuit can be stopped by setting voltage and time parameters |
Device circuit resistance | <5m,>5m&<10m,>10m&<20m,>40m&<50m,>80m&<100m, the corresponding |
Short circuit terminal wiring | <5m,>5m&<10m,>10m&<20m,>40m&<50m,>80m&<100m, 1 pair each, |
Short circuit internal resistance switching mode | Manual switching, one end of the short-circuit terminal wire is a through nose, |
Short circuit test response time | ≤10ms |
Mechanical life | 300,000 times |
Electrical life | 50,000 times |
Remote control distance | No solid barrier 10m |
short circuit time | 0-9999H59M59S can be set |
Customer Support Services:
Ø Installation
Ø Training (Training customer employees)
Ø Preventative maintenance
Ø Replacement parts
Ø Assistance via phone or internet
Ø On-site diagnosis and repair/online diagnosis and repair
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
1997
Total Annual:
20000000-30000000
Employee Number:
50~100
Ecer Certification:
Active Member
Company Profile The company had grown very fast since it was founded in 2009 which holds the operation concepts of being morality-rooted and honesty-based, FREETO® has earned great reputation globally with our excellent service and quality. Guided by the FREETO® mission, “Perfect Qu... Company Profile The company had grown very fast since it was founded in 2009 which holds the operation concepts of being morality-rooted and honesty-based, FREETO® has earned great reputation globally with our excellent service and quality. Guided by the FREETO® mission, “Perfect Qu...