Payment Terms | T/T |
Supply Ability | 50 Sets per Month |
Delivery Time | 10 Working Days |
Packaging Details | Plywood Box |
Dimension | Interior 160 x 100 x 550cm |
Temperature | NSS ACSS 35℃ ± 1℃ |
Safety Device | Over-temperature Protection |
PH Range | CASS: 3.0~3.2 |
Uniformity | ≦2. 0℃ |
Spray Quantum | 1.0~2.0(ml/80cm2/h) |
Brand Name | iqualitrol |
Model Number | HL-160-SS |
Certification | |
Place of Origin |
View Detail Information
Explore similar products
Copper Accelerated Acetic Acid Salt Spray CASS Test Machine With High Performanc
Environmental Climate Salt Spray Test Chamber / Corrosion Testing Apparatus
neutral Salt Spray Test Chamber with push button pannel in light grey color
270L CASS Salt Spray Test Chamber For Electronic / Car Industry
Product Specification
Payment Terms | T/T | Supply Ability | 50 Sets per Month |
Delivery Time | 10 Working Days | Packaging Details | Plywood Box |
Dimension | Interior 160 x 100 x 550cm | Temperature | NSS ACSS 35℃ ± 1℃ |
Safety Device | Over-temperature Protection | PH Range | CASS: 3.0~3.2 |
Uniformity | ≦2. 0℃ | Spray Quantum | 1.0~2.0(ml/80cm2/h) |
Brand Name | iqualitrol | Model Number | HL-160-SS |
Certification | Place of Origin | ||
High Light | salt mist chamber ,salt fog test chamber |
Corrosion Resistant Salt Spray Test Chamber For Quality Control Paint Electroplating
Brief Introduction:
Most Salt Spray Chambers today are being used NOT to predict the corrosion resistance of a coating, but to maintain coating processes such as pre-treatment and painting, electroplating, galvanizing, and the like, on a comparative basis.
Seawater Acidified Test (cyclic) can be used to test the relative resistance to corrosion of coated or uncoated aluminium alloys and other metals, when exposed to a changing climate of acidified synthetic seawater spray, followed by a high humidity, both at an elevated temperature.
This test is also referred to as a SWAAT test. Test specimens are placed in an enclosed chamber, and exposed to a changing climate that comprises the following 2 part repeating cycle. 30 minutes exposure to a continuous indirect spray of synthetic seawater solution, prepared in accordance with the requirements of the test standard and acidified (to pH 2.8 to 3.0) by the addition of acetic acid.
This spray is set to fall-out on to the specimens at a rate of 1.0 to 2.0ml/80 cm²/hour. This is followed by 90 minutes exposure to a high humidity climate of above 98%RH. The entire test cycle is at a constant chamber temperature of +49C (may be reduced to +24 to +35C for organically coated specimens). The number of cycle repeats and therefore the test duration is variable
Main Features:
1, Chamber material is made of P.V.C Sheet, sturdily and will not be out of shape.
2, Test chamber is heated from five directions to ensure the temperature is uniformity distributed.
3, Spray nozzle is specially made, enable to spray the salt water with considerable speed, then falls on the surface of samples.
4, Hot and moist air keeps the humidity in the test chamber conforms testing request.
5, High precision P.I.D. temperature controller limits the temperature difference within the range of ±0.1℃.
Technical Specifications:
Please note: HL-60-SS, HL-60-CS and HL-90-BS, HL-90-CS do not meet standard of ASTM B117.
Model | HL-60-SS | HL-90-BS | HL-120-NS | HL-160-NS | HL-200-NS | ||
Model (Touch Screen) | HL-60-CS | HL-90-CS | HL-120-CS | HL-160-CS | HL-200-CS | ||
Interior dimensions (mm) |
W | 600 | 900 | 1200 | 1600 | 2000 | |
D | 450 | 600 | 850 | 1000 | 1200 | ||
H | 400 | 500 | 500 | 550 | 600 | ||
Exterior dimensions (mm) |
W | 1130 | 1460 | 2200 | 2600 | 3000 | |
D | 630 | 910 | 1200 | 1450 | 1650 | ||
H | 1070 | 1280 | 1450 | 1550 | 1600 | ||
Chamber Volume | 108 L | 270 L | 480 L | 800 L | 1440 L | ||
Solution Tank | 15L | 25 L | 40 L | ||||
Power Supply | AC 220V 50HZ | AC 380V 50HZ | |||||
Ambient temp. & humid. range | +5℃ ~ +35℃ / <85%RH | ||||||
Testing Temperature | NSS ACSS 35℃±1℃ / CASS 50℃±1℃ | ||||||
Air Temperature | NSS ACSS 47℃±1℃ /CASS 63℃±1℃ | ||||||
Solution Consistence | NaCl 5% | ||||||
PH Value | NASS ACSS:6.5~7.2 / CASS:3.0~3.2 | ||||||
Temperature fluctuation | ≦±0.5℃ | ||||||
Temperature uniformity | ≦2. 0℃ | ||||||
Temperature deviation | ≦±2.0℃ | ||||||
Spray quantum | 1.0~2.0(ml/80cm2/h) | ||||||
Chamber Material | polyvinyl chloride (PVC) | ||||||
Heater | Corrosion-resistant titanium tube | ||||||
Temperature sensor | Platinum Resistance (PT-100) | ||||||
Safety device | Over-temperature protection , leakage protection |
Note:
1. The above specifications are for reference only, the actual specifications for the main quotation.
2. Custom made is available according to customers’ special requirements
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2000
Total Annual:
700000-1000000
Employee Number:
50~75
Ecer Certification:
Site Member
DongGuan Q1-Test Equipment Co., Ltd. was founded in year 2000, located in DongGuan, a famous industrial city. Mainly specialized in manufacturing, developing and marketing various environmental testing equipment like programmable temperature and humidity test chamb... DongGuan Q1-Test Equipment Co., Ltd. was founded in year 2000, located in DongGuan, a famous industrial city. Mainly specialized in manufacturing, developing and marketing various environmental testing equipment like programmable temperature and humidity test chamb...