Payment Terms | T/T |
Supply Ability | 10 Sets per Month |
Delivery Time | 10 Working Days |
Packaging Details | Plywood Box |
Dimension | Interior 160 x 100 x 550cm |
Temperature | NSS ACSS 35℃ ± 1℃ |
Safety Device | Over-temperature Protection |
PH Range | CASS: 3.0~3.2 |
Uniformity | ≦2. 0℃ |
Spray Quantum | 1.0~2.0(ml/80cm2/h) |
Brand Name | iqualitrol |
Model Number | HL-160-SS |
Certification | |
Place of Origin |
View Detail Information
Explore similar products
Copper Accelerated Acetic Acid Salt Spray CASS Test Machine With High Performanc
Environmental Climate Salt Spray Test Chamber / Corrosion Testing Apparatus
neutral Salt Spray Test Chamber with push button pannel in light grey color
270L CASS Salt Spray Test Chamber For Electronic / Car Industry
Product Specification
Payment Terms | T/T | Supply Ability | 10 Sets per Month |
Delivery Time | 10 Working Days | Packaging Details | Plywood Box |
Dimension | Interior 160 x 100 x 550cm | Temperature | NSS ACSS 35℃ ± 1℃ |
Safety Device | Over-temperature Protection | PH Range | CASS: 3.0~3.2 |
Uniformity | ≦2. 0℃ | Spray Quantum | 1.0~2.0(ml/80cm2/h) |
Brand Name | iqualitrol | Model Number | HL-160-SS |
Certification | Place of Origin | ||
High Light | salt mist chamber ,salt fog test chamber |
Programmable Temperature Humidity Salt Spray Test Chamber
with Micro Controller
Brief Introduction:
Neutral Salt Spray, to be accepted for production. Failure to meet this requirement implies instability in the chemical process of the pre-treatment, or the paint quality, which must be addressed immediately, so that the upcoming batches are of the desired quality. The longer the accelerated corrosion test, the longer the process remains out of control, and larger is the loss in the form of non-conforming batches.
Salt Spray Test duration depends on the corrosion resistance of the coating; generally, the more corrosion resistant the coating is, the longer the period of testing before the appearance of corrosion/ rust. The salt spray test is one of the most widespread and long established corrosion tests.
Acetic Acid Salt Spray Test (non-cyclic) can be used to determine the relative resistance to corrosion of decorative chromium plating on steel and zinc based die casting when exposed to an acetic acid salt spray climate at an elevated temperature.
Test specimens are placed in an enclosed chamber and exposed to a continuous indirect spray of salt water solution, prepared in accordance with the requirements of the test standard and acidified (to pH 3.1 to 3.3) by the addition of acetic acid. This spray is set to fall-out on to the specimens at a rate of 1.0 to 2.0ml/80 cm²/hour, in a chamber temperature of +35C. This climate is maintained under constant steady state conditions. The test duration is variable.
Most Salt Spray Chambers today are being used NOT to predict the corrosion resistance of a coating, but to maintain coating processes such as pre-treatment and painting, electroplating, galvanizing, and the like, on a comparative basis.
Features:
1, Chamber material is made of P.V.C Sheet, sturdily and will not be out of shape.
2, Test chamber is heated from five directions to ensure the temperature is uniformity distributed.
3, Spray nozzle is specially made, enable to spray the salt water with considerable speed, then falls on the surface of samples.
4, Hot and moist air keeps the humidity in the test chamber conforms testing request.
5, High precision P.I.D. temperature controller limits the temperature difference within the range of ±0.1℃.
Technical Specifications:
Please Note Small Type of 60 and 90 do not meet standard of ASTM B117.
Model | HL-60-SS | HL-90-BS | HL-120-NS | HL-160-NS | HL-200-NS | ||
Model (Touch Screen) | HL-60-CS | HL-90-CS | HL-120-CS | HL-160-CS | HL-200-CS | ||
Interior dimensions (mm) |
W | 600 | 900 | 1200 | 1600 | 2000 | |
D | 450 | 600 | 850 | 1000 | 1200 | ||
H | 400 | 500 | 500 | 550 | 600 | ||
Exterior dimensions (mm) |
W | 1130 | 1460 | 2200 | 2600 | 3000 | |
D | 630 | 910 | 1200 | 1450 | 1650 | ||
H | 1070 | 1280 | 1450 | 1550 | 1600 | ||
Chamber Volume | 108 L | 270 L | 480 L | 800 L | 1440 L | ||
Solution Tank | 15L | 25 L | 40 L | ||||
Power Supply | AC 220V 50HZ | AC 380V 50HZ | |||||
Ambient temp. & humid. range | +5℃ ~ +35℃ / <85%RH | ||||||
Testing Temperature | NSS ACSS 35℃±1℃ / CASS 50℃±1℃ | ||||||
Air Temperature | NSS ACSS 47℃±1℃ /CASS 63℃±1℃ | ||||||
Solution Consistence | NaCl 5% | ||||||
PH Value | NASS ACSS:6.5~7.2 / CASS:3.0~3.2 | ||||||
Temperature fluctuation | ≦±0.5℃ | ||||||
Temperature uniformity | ≦2. 0℃ | ||||||
Temperature deviation | ≦±2.0℃ | ||||||
Spray quantum | 1.0~2.0(ml/80cm2/h) | ||||||
Chamber Material | polyvinyl chloride (PVC) | ||||||
Heater | Corrosion-resistant titanium tube | ||||||
Temperature sensor | Platinum Resistance (PT-100) | ||||||
Safety device | Over-temperature protection , leakage protection |
Note:
1. The above specifications are for reference only, the actual specifications for the main quotation.
2. Custom made is available according to customers’ special requirements
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2000
Total Annual:
700000-1000000
Employee Number:
50~75
Ecer Certification:
Site Member
DongGuan Q1-Test Equipment Co., Ltd. was founded in year 2000, located in DongGuan, a famous industrial city. Mainly specialized in manufacturing, developing and marketing various environmental testing equipment like programmable temperature and humidity test chamb... DongGuan Q1-Test Equipment Co., Ltd. was founded in year 2000, located in DongGuan, a famous industrial city. Mainly specialized in manufacturing, developing and marketing various environmental testing equipment like programmable temperature and humidity test chamb...
Get in touch with us
Leave a Message, we will call you back quickly!