Compressed air pressure | 1.00±0.01kgf/cm2 |
Amount of spray | 1.0-2.0ml/80cm2.h |
Laboratory volume | 800L |
Laboratory temperature | NSS ACSS 35℃±1℃/ CASS 50℃±1℃ |
Pressure tank temperature | NSS ACSS 47℃±1℃/ CASS 63℃±1℃ |
Laboratory relative humidity | More than 85% |
Brand Name | JIEDONG |
Model Number | JD-160 |
Place of Origin | Guangdong, China |
View Detail Information
Explore similar products
Air Pressure 1kg/cm2 Salt Spray Test Machine Jd-90a Touch Screen
JIEDONG Salt Spray Test Chamber Jd-90 Laboratory 35 °c ± 1 °c CASS
Salt Spray Test Machine Pvc Plate Thickness 5mm Box Jd-60a 50ml Measuring
Imported P.v.c Plate Salt Spray Test Chamber Jd-120a Touch Screen Test Machine
Product Specification
Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash, escrow | Supply Ability | 80 sets per month |
Delivery Time | 20 workdays after order confirmed | Packaging Details | standard export plywood |
Compressed air pressure | 1.00±0.01kgf/cm2 | Amount of spray | 1.0-2.0ml/80cm2.h |
Laboratory volume | 800L | Laboratory temperature | NSS ACSS 35℃±1℃/ CASS 50℃±1℃ |
Pressure tank temperature | NSS ACSS 47℃±1℃/ CASS 63℃±1℃ | Laboratory relative humidity | More than 85% |
Brand Name | JIEDONG | Model Number | JD-160 |
Place of Origin | Guangdong, China | ||
High Light | salt spray test equipment ,temp humidity chamber |
Salt Water Tank Volume 35l Salt Spray Test Machine Jd-160 Salt Spray Test Machine
JD-160 salt spray test machine technical parameters
Scope of application:
The salt spray test machine is used for the surface treatment of various materials, including coatings, electroplating, organic and inorganic coatings, anodizing, anti-rust oil and other anti-corrosion treatments to test the corrosion resistance, thus establishing the quality of the product.
First, salt spray test box JD-160 specifications
Internal dimensions | 1600×1000×500(L×W×H)mm |
External size | About 2000 × 1400 × 1400 (L × W × H) mm |
Laboratory temperature | NSS ACSS 35℃±1℃/ CASS 50℃±1℃ |
Pressuretanktemperature | NSS ACSS 47℃±1℃/ CASS 63℃±1℃ |
Laboratory volume | 800L |
Saltwatertankvolume | 35L |
Compressedairpressure | 1.00±0.01kgf/cm2 |
Amount of spray | 1.0-2.0ml/80cm2.h |
Laboratory relative humidity | More than 85% |
Second, the salt spray test box JD-160 features:
1. | Imported gray P.V.C plate system, special treatment for corrosion resistance. The plastic steel V-shaped frame and the stainless steel pipe angle are placed to ensure that the test object is at an angle of 30 degrees, and the six-wheel sliding can be pushed away. |
2. | Fine workmanship, beautiful appearance, high transparency, pneumatic opening. |
3. | Automatic/manual watering system with automatic/manual water replenishment when the water level is insufficient. The experiment is not interrupted to meet the diverse environmental requirements of the guests. (Automatic hydration only needs to access the water pipe) |
4. | Nozzle: The spray tower is equipped with a cone disperser, which has the functions of guiding the mist, adjusting the amount of fog, and evenly fogging. |
5. | The high-precision multi-function timer is used, and the test time can be set to multi-function. With the power-off memory function, the time is continued before the call is turned off, until the product is completed, and the experiment is redone after the power failure. |
6. | In the salt spray experiment, the steam is directly heated, the heating rate is fast, the temperature distribution is uniform, and the standby time is shortened. |
7. | Two-button automatic operation. With a full detection failure warning system. Lights up and buzzer when a fault occurs |
8. | Two built-in mist collection cylinders are used. It is less susceptible to damage than traditional external models. |
9. | With overload protection for short circuit. Prevent damage to the instrument and the internal electronic control accessories of the instrument when an abnormality occurs. |
10. | The inner and outer cabinets are connected to the sealing groove and sealed with water to prevent salt spray from leaking out. |
11. | The inlet temperature controller uses a digital display with PID control with an error of ±0.1 °C. |
12. |
Temperature range: 1: Laboratory temperature: 35 ° C - Pressure tank temperature: 50 ° C (can be set arbitrarily) 2: Laboratory temperature: 47 ° C - pressure barrel temperature: 63 ° C (can be set arbitrarily) |
13. | The reagent refilling bottle adopts a hidden water-filled perspective window, which is easy to clean and is not easy to be broken. |
14. | Heating rate: 1: laboratory, room temperature---→35°C, about 35 minutes 2: Pressure tank, normal temperature---→47°C, about 15 minutes |
15. | Temperature accuracy: ±1 °C |
16 | Applicable international standards: RELATEU STANDARDS CNS 3627, 3885, 4159, 7669, 8866; JIS D-0201, H-8502, H-8610, K-5400, Z-2371, ISO3768, 3769, 3770; ASTM B-117, ASTM B-268 B-268, GB-T2423, GJB150. |
Third, salt spray test box JD-160 control panel and electrical accessories:
Thermostat (Changzhou Huibang) | 2 |
Pressure gauge (KKK, Japan) | 1 |
Indicator light (Taiwan) | 5 |
Timer (Japan Omron) | 1 |
Control switch (Taiwan) | 2 |
SSR (Taiwan Yangming) | 2 |
Relay (Japan Omron) | 1 |
Temperature line (Taiwan Shenjie) | 2 pieces |
Pressure regulator (Japan SMC) | 2 |
Solenoid valve (Japan Omron) | 4 |
Fourth, the internal device
Spray tower | 2 sets |
Shelf | 10 |
Storage stick | 14 |
Standard measuring cylinder | 2 |
Temperature indicator | 2 |
collector | 2 |
Glass nozzle | 2 |
Defogging system | Group 1 |
Five, random attachments
1. | Test drug sodium chloride (Nacl) 500 g | 2 bottles |
2. | Operating instructions and warranty card | 1 serving |
3. | 5L plastic measuring cup | 1 |
Six, service commitment
The machine provides a 12-month free warranty and lifetime maintenance (except for human reasons and force majeure)
Refer to the picture, which is subject to the actual product
Company Details
Business Type:
Seller
Year Established:
2012
Total Annual:
300-500
Employee Number:
100~200
Ecer Certification:
Active Member
Dongguan Jiedong Test Equipment Co., Ltd. ... Dongguan Jiedong Test Equipment Co., Ltd. ...
Get in touch with us
Leave a Message, we will call you back quickly!