Supply Ability | 500 sets / month |
Delivery Time | 2-4 weeks |
Packaging Details | carton |
Product Name | Modular inverters |
DC voltage (input range) | 125Vdc |
AC voltage (input range) | 120Vac |
Output power | 1KVA /2 KVA/ 3kVA |
Output Efficiency | 85% |
Weight | 11.5 kg |
Certification | CE |
Place of Origin | CN |
Model Number | BWT125/120-1KVA |
View Detail Information
Explore similar products
CE+T Modular Dc To Ac Power Inverter TSI BRAVO 110/230 110Vdc 230Vac 2.5kva 2kw
CE+T TSI Bravo125/120 With Extra AC Input 125Vdc 120Vac 2.5KVA 2.5KW P/N
CET Modular Dc Ac Inverters TSI Bravo 60/230 With Extra AC Input 60Vdc 230Vac 2
TSI Bravo 24/230 Dc Ac Inverters 1.5kva 1.2kw 24Vdc For Low DC Voltage P/N
Product Specification
Supply Ability | 500 sets / month | Delivery Time | 2-4 weeks |
Packaging Details | carton | Product Name | Modular inverters |
DC voltage (input range) | 125Vdc | AC voltage (input range) | 120Vac |
Output power | 1KVA /2 KVA/ 3kVA | Output Efficiency | 85% |
Weight | 11.5 kg | Certification | CE |
Place of Origin | CN | Model Number | BWT125/120-1KVA |
High Light | 3kva DC AC Inverters ,125v to 120v DC AC Inverters ,19 Inch pure sine wave inverter |
The pure sine wave DT-1000 Series inverters are BWITT new expand
customize inverter. This Series is a professional 19” rack enclosure with a
wide range of options to suit applications.
Description:
Main features:
Application:
All business critical applications and all types of AC loads.
The design is modular and scalable with hot- swappable
inverter modules which ensures low Mean Time to Repair
reduction in service costs and meets the changing
needs for future expansion.
Model | BWT125/120-1KVA BWT125/120-3KVA | BWT125/120-2KVA | BWT125/120-3KVA | |||
INPUT | ||||||
Battery Input Voltage | 125Vdc | |||||
Battery Voltage Range | 100-150Vdc | |||||
DC Input Current | 10A Max | 20A Max | 30A Max | |||
Bypass Input Voltage | 120VACNorm 66.6A Max | |||||
Bypass Voltage Range | 100-140VAC 30A Max 50A Max 60AMax | |||||
AC Input Frequency | 60Hz | |||||
Frequency Range | 43~67Hz | |||||
PF | >0.8 | |||||
OUTPUT | ||||||
Output Capacity | 1000VA | 2000VA | 3000VA | |||
Rated Output Capacity | 800W | 1600W | 2400W | |||
Rated output Voltage | 120VAC (Inverter Mode )- | |||||
Rated Output Current | 6.67A | 13.3A | 20A | |||
Output Voltage Range | 120Vac(Tolerance ±1.5% @Inverter Mode) | |||||
Output Efficiency | ≥85% (Inverter Mode) | |||||
Output Frequency | 60Hz | |||||
Output Wave | Pure Sine | |||||
THD | ≤3% (Line Load) | |||||
Switch Time (By pass to Inverter mode) | ≤5ms (With Load) | |||||
PROTECTIVE FEATURE | ||||||
AC Under Vol. Switch Protection | ≤90Vac (Backlash voltage≥10Vac) | |||||
AC over Volt. Switch protection | ≥140AC | |||||
Over-Temperature | Yes (Auto Switch) | |||||
BAT. under vol. protection point | ≤90 | |||||
Battery Low-voltage alarm | 90±0.5 | |||||
Battery overvoltage protection point | ≥155VDC | |||||
Battery overvoltage recovery point | ≥145VDC | |||||
Cooling | 2*Fans 4*Fans | 2*Fans | 4*Fans | |||
Temp.Control@ Inner Temp.>45℃ & Speed According to the output Capacity@ Output Capacity >50% | ||||||
OUTPUT OVER CURRENT PROTECTION | ||||||
Over Load Capacity | Continue working @overload 110% | |||||
Over Load Capacity | Continue working 60s @ overload 110%~130% | |||||
Over Load Capacity | Continue working 10s @over load >150% | |||||
Over Temp. Protection | Yes | |||||
short circuit Protection | Yes (Don’t test under AC Connect) | |||||
Reverse connection protection | Yes | |||||
Output OVP | ≥144VAC(Inverter Mode) | |||||
Output low voltage alarm | ≤88VAC (Inverter Mode) | |||||
SAFETY AND EMC | ||||||
Dielectric strength(AC-Chassis) | 3500Vdc/10mA//1min .No flash over, no breakdown, no arc (Only AC Input priority) | |||||
Dielectric strength(DC-Chassis) | 750Vdc/10mA/1min. No flash over, no breakdown
| |||||
LVD | EN 60950-1 | |||||
EMC/EM I | EN 61000-6-3; EN 61000-6-1 ;IEC 61000-6-2 and IEC 61000-6-4 | |||||
ROHS
| IEC 62321-4, IEC 62321-5, IEC 62321-6, IEC 62321-7, IEC 62321-8
| |||||
ENVIRONMENT TEST PERFORMANCE | ||||||
Ambient Temp. | -20~ +50℃ | |||||
High temperature operation | 50±2℃ (rated load 24H) | |||||
Low temperature operation | -20±2℃ (rated load 24H) | |||||
High temperature storage | 80±2 ℃,24H | |||||
Low temperature storage | -40±2℃,24H | |||||
Humidity | 0~90%,No moisture condensation | |||||
Operating Altitude (m) | Altitude Full power below2000m. >2000m derating -2% / 100m, max altitude 5000m | |||||
COMMUNICATION | ||||||
Rs232 & Rs485 | Yes | |||||
SNMP | Optional | |||||
Dry Contact | 5 group | |||||
LCD DISPLAY | ||||||
LCD Status
| Input and output Voltage, Frequency, Output Current, Temp., Load Rate, LOGO etc.
| |||||
Inverter Status
| Normal Mains, Normal Inverter, Battery Under-voltage and output overload etc.
| |||||
MEASUREMENT | ||||||
Size W*D*H(mm) | 482*347*88mm | 482*430*88mm | ||||
Weight | 11.5KG | 15KG |
more......
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Trading Company
Year Established:
2017
Total Annual:
4,000,000-5,000,000
Employee Number:
20~30
Ecer Certification:
Verified Supplier
Ding Ding Future Power Company provide professional solutions to the telecommunications and network power industries across Africa,the Middle East , South America and Southeast Asia clients. we have grown rapidly since our inception in 2017 as a small company for telecom after-sale serv... Ding Ding Future Power Company provide professional solutions to the telecommunications and network power industries across Africa,the Middle East , South America and Southeast Asia clients. we have grown rapidly since our inception in 2017 as a small company for telecom after-sale serv...
Get in touch with us
Leave a Message, we will call you back quickly!