Payment Terms | L/C, T/T |
Supply Ability | 3000 pieces per month |
Delivery Time | 8-10 weeks |
Packaging Details | cartons |
Brand | MEAN WELL |
Product Name | AC-DC Bidirectional Power Supply |
Output currency | 180A-22.5A |
Rated power | 2160W |
Input frequency | 47 ~ 63Hz |
DC voltgae | 12V-48V |
Input Voltage | 90 ~ 264VAC / 127 ~370VDC |
Protection | over voltgae / over load |
Dimension | 330*140*41mm (L*W*H) |
Weight | 4 KG |
Brand Name | MEAN WELL |
Model Number | BIC-2200 |
Certification | CE |
Place of Origin | CN |
View Detail Information
Explore similar products
Eltek Flatpack S 36V/1000W HE UI Rectifier Module Part No 241123.235
Mean Well Brand DIN Rail Power Supply EDR-75 EDR-120 EDR-150
240W Three Phase TDR-240-24 Industrial DIN Rail Built In Active PFC
SDR-75-24 Meanwell Din Rail Power Supply 12V 24V 48V 85%-89%
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 3000 pieces per month |
Delivery Time | 8-10 weeks | Packaging Details | cartons |
Brand | MEAN WELL | Product Name | AC-DC Bidirectional Power Supply |
Output currency | 180A-22.5A | Rated power | 2160W |
Input frequency | 47 ~ 63Hz | DC voltgae | 12V-48V |
Input Voltage | 90 ~ 264VAC / 127 ~370VDC | Protection | over voltgae / over load |
Dimension | 330*140*41mm (L*W*H) | Weight | 4 KG |
Brand Name | MEAN WELL | Model Number | BIC-2200 |
Certification | CE | Place of Origin | CN |
High Light | bidirectional power supply 2160W 12V 180A ,BIC-2200-12 2160W 12V 180A ,bidirectional power supply BIC-2200-12 2160W 12V 180A |
Mean Well BIC-2200 AC-DC Bidirectional Power Supply 2160W 12V 180A output BIC-2200-12
1U low profile design
Full digital design with 93% conversion efficiency for both AD/DC and DC/AD conversion
Ultrafast switching time between AD/DC and DC/AC of 1ms.
CB/TUV/UL 62368-1 certified, and design refer to IEC 62477 regulation
Active current sharing up to 11000W(4+1)
< 3% Low THD in both conversion mode
Force charging and recycle mode with CANbus commend(Optional)
Complete protections: Anti-islanding protection, AC fail protection, DC OVP, OLP, OCP, OTP
5 years warranty
Technical
AC to DC Direction | MODEL | BIC-2200-12 | BIC-2200-24 | BIC-2200-48 | BIC-2200-96 | ||||
OUTPUT | DC VOLTAGE | 12V | 24V | 48V | 96V | ||||
RATED CURRENT | 180A | 90A | 45A | 22.5A | |||||
RATED POWER | 2160W | ||||||||
FULL POWER VOLTAGE RANGE | 12 ~ 15V | 24 ~ 28V | 48 ~ 65V | 96 ~ 112V | |||||
RIPPLE & NOISE (max.) Note.2 | 160mVp-p | 260mVp-p | 300mVp-p | 480mVp-p | |||||
VOLTAGE ADJ. RANGE | 10 ~ 15V | 19 ~ 28V | 38 ~ 65V | 76 ~ 112V | |||||
CURRENT RANGE | 0 ~ 180A | 0 ~ 90A | 0 ~ 45A | 0 ~ 22.5A | |||||
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||||
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||||
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||||
SETUP, RISE TIME | 1800ms, 60ms/230VAC at full load | ||||||||
INPUT | AC VOLTAGE RANGE | 180 ~ 264VAC | |||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||
POWER FACTOR (Typ.) | 0.98/230VAC at full load | ||||||||
EFFICIENCY (Typ.) Note.5 | 90% | 93% | 93% | 93% | |||||
AC CURRENT (Typ.) | 11A/230VAC | ||||||||
INRUSH CURRENT (Typ.) | COLD START 35A/230VAC | ||||||||
LEAKAGE CURRENT | <2mA/230VAC | ||||||||
TOTAL HARMONIC DISTORTION | <3%(@load=100%/230VAC) | ||||||||
DC to AC Direction |
INPUT (Note.9) | RATED INPUT POWER | 1800W | ||||||
FULL POWER VOLTAGE RANGE | 12 ~ 15V | 24 ~ 28V | 48 ~ 65V | 96 ~ 112V | |||||
DC VOLTAGE RANGE | 10 ~15V | 19 ~ 28V | 38 ~ 65V | 76 ~ 112V | |||||
MAX. INPUT CURRENT | 150A | 75A | 37.5A | 18.75A | |||||
OUTPUT | RATED OUTPUT POWER (Typ.) (@230V, 50Hz) | 1725VA | |||||||
VOLTAGE RANGE | 180 ~ 264VAC determined by AC main | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz determined by AC main | ||||||||
AC CURRENT (Typ.) | 7.5A/230VAC | ||||||||
POWER FACTOR (Typ.) | 0.99/230VAC at full load | ||||||||
EFFICIENCY (Typ.) Note.5 | 90.5% | 93% | 93% | 93% | |||||
TOTAL HARMONIC DISTORTION | <3%(@load=100%/230VAC) | ||||||||
PROTECTION |
OVER LOAD | 105 ~ 115% rated output power | |||||||
AC to DC | Constant current limiting, shut down DC O/P voltage 5 sec. after DC O/P voltage is down low, re-power on to recover | ||||||||
DC to AC | Not accurable with constant power design | ||||||||
SHORT CIRCUIT | Shut down O/P current, re-power on to recover | ||||||||
OVER VOLTAGE | 17.6 ~ 20.8V | 33.6 ~ 39.2V | 72.6 ~ 86V | 134 ~ 157V | |||||
Protection type : Shut down O/P voltage, re-power on to recover | |||||||||
OVER TEMPERATURE | Shut down O/P voltage, recovers automatically after temperature goes down | ||||||||
ISLANDING PROTECTION | Shut down AC O/P voltage, re-power on to recover | ||||||||
FUNCTION | REMOTE ON-OFF CONTROL | By electrical signal or dry contact Short: Power ON Open: Power OFF Please refer to the Function Manual infollowing | |||||||
BIDIRECTION SWITCH TIME (Typ.) | 1ms | ||||||||
ALARM SIGNAL | Isolated TTL signal output for T-Alarm, DC-OK and Fault. Please refer to the Function Manual in following pages | ||||||||
AUXILIARY POWER | 12V@0.5A tolerance±5%, ripple 150mVp-p | ||||||||
BATTERY MODE RATED CURRENT(default) Note.7 | AC to DC | 160A | 80A | 40A | 20A | ||||
Can be adjusted by communication | |||||||||
DC to AC | 120A | 64A | 32A | 16A | |||||
Can be adjusted by communication | |||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Refer to "Derating Curve") | |||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 45℃) | ||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | UL62368-1, CAN/CSA C22.2 No.62368-1,TUV BS EN/EN62368-1, EAC TP TC 004, IEC62477-1(by request) approved | |||||||
WITHSTAND VOLTAGE Note.8 | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:500VAC | ||||||||
ISOLATION RESISTANCE Note.8 | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||
EMC EMISSION | BS EN/EN55032 | ||||||||
Parameter | Standard | Test Level / Note | |||||||
Conducted | BS EN/EN55032 (CISPR32) | Class B | |||||||
Radiated | BS EN/EN55032 (CISPR32) | Class A | |||||||
Harmonic Current | BS EN/EN61000-3-2 | Class A | |||||||
Voltage Flicker | BS EN/EN61000-3-3 | ----- | |||||||
EMC IMMUNITY | BS EN/EN55035, BS EN/EN61000-6-2 | ||||||||
Parameter | Standard | Test Level / Note | |||||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | |||||||
Radiated | BS EN/EN61000-4-3 | Level 3 | |||||||
EFT / Burst | BS EN/EN61000-4-4 | Level 3 | |||||||
Surge | BS EN/EN61000-6-2 | 2KV/Line-Line 4KV/Line-Earth | |||||||
Conducted | BS EN/EN61000-4-6 | Level 3 | |||||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | |||||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods | |||||||
OTHERS | MTBF | 462.9K hrs min. Telcordia SR-332 (Bellcore) ; 46K hrs min. MIL-HDBK-217F (25℃) | |||||||
DIMENSION | 330*140*41mm (L*W*H) | ||||||||
PACKING | 2.9Kg; 4pcs/12.6Kg/1.25CUFT |
Solutions
We provide a complete solutions including site survey, propose professional plan according to customer’s request ,technical support, and maintenance service for Telecommunication Companies in and out of China. We have a competent team and a network of trusted Partners around the world.
FAQ :
1. How do you control the quality?
A:All products before the shipment are simulated usage scenarios, load and full load and current sharing test to ensure the quality of the product.
2. What is your minimum order quantity?
A:There is no minimum order quantity, and one can also be done. The only difference is the price and schedule.
3. Can you introduce your company?
A:I am very honored. I will send you the company’s introduction document later to give you a more comprehensive and direct introduction to our company’s information.
4. What are the advantages of your company?
A:Adequate inventory, and supply guarantee for the subsequent renewal of supply, flexible provided according to different to different needs of customers, providing different solutions.
5. Can i send samples?Report it to me along with the price?
A:You can send samples, the samples are subject to large pride, and the freight needs to be borne by you.
6. How do your company deal with the problem on quality?
A:Our company has been doing this industry for almost 10 years. It has already had a certain reputation. We will carefully analyze it. If it is indeed our quality problem, you can rest assured that it will do things according to the contract agreement and will never let you have any after the worries, our service team will be happy to serve you.
7 What about the quality ?
A:100% original with new package. we will test each item before posted to make sure each item with good quality.
8 How many months for guarantee ?
A: 1 year quality guarantee
9 How to deal with any inferior -quality goods ?
A: Goods can be post by with our charge of post fee for any bad quality products within guarantee time.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Trading Company
Year Established:
2017
Total Annual:
4,000,000-5,000,000
Employee Number:
20~30
Ecer Certification:
Verified Supplier
Ding Ding Future Power Company provide professional solutions to the telecommunications and network power industries across Africa,the Middle East , South America and Southeast Asia clients. we have grown rapidly since our inception in 2017 as a small company for telecom after-sale serv... Ding Ding Future Power Company provide professional solutions to the telecommunications and network power industries across Africa,the Middle East , South America and Southeast Asia clients. we have grown rapidly since our inception in 2017 as a small company for telecom after-sale serv...
Get in touch with us
Leave a Message, we will call you back quickly!