Payment Terms | T/T, L/C, Western Union, MoneyGram,Paypal |
Supply Ability | 1000pcs per month |
Delivery Time | 3-7 working days |
Packaging Details | Carton box |
Material | Brass |
Refrigerant | R134a, R404A, R507, R22, R407C |
Display type | LED |
Application | Refrigeration Parts |
Weight | 0.38kg |
Connection Type | Solder |
Valve type | energy regulators |
Name | energy regulation adjusting, hot gas bypass valve |
Brand Name | |
Model Number | KVC KVD Series |
Certification | CE/ UL |
Place of Origin | Denmar/kChina |
View Detail Information
Explore similar products
HVAC Thermostatic Expansion Valves TGE series TGEX R22/-25℃ -40℃with or without
HVAC Solenoid Valve coil refrigeration system controls EVR Series 12V to 240V
HVAC coil for Solenoid Valve refrigeration system controls 018F6176 10W 50HZ 220
HVAC coil for Solenoid Valve refrigeration system controls 018F6701 10W 50HZ 220
Product Specification
Payment Terms | T/T, L/C, Western Union, MoneyGram,Paypal | Supply Ability | 1000pcs per month |
Delivery Time | 3-7 working days | Packaging Details | Carton box |
Material | Brass | Refrigerant | R134a, R404A, R507, R22, R407C |
Display type | LED | Application | Refrigeration Parts |
Weight | 0.38kg | Connection Type | Solder |
Valve type | energy regulators | Name | energy regulation adjusting, hot gas bypass valve |
Brand Name | Model Number | KVC KVD Series | |
Certification | CE/ UL | Place of Origin | Denmar/kChina |
HVAC KVC energy regulators,energy regulation adjusting,hot gas bypass valve,KVD receiver pressure regulator
capacity regulators are used to adapt compressor capacity to actual evaporator load by supplying a replacement capacity in the form of hot/cool gas.
They are installed in a bypass line between the high and low-pressure sides of the refrigeration system and are designed for direct gas injection into the suction line.
693723 imposes a lower limit on the compressor suction pressue by supplying the low pressure side with replacement capacity in the form of hot gas/cool gas from the high pressure side.
◆ KVC energy regulator is used to adjust the compressor cooling capacity, so that it is compatible with the evaporator load
◆ KVC energy regulator installed in the cooling system between the high / low side of the bypass pipeline
◆ KVC through the bypass line of high-pressure side of the hot air into the low side instead of part of the load, so that the compressor suction pressure is not less than the minimum limit
Product Features:
◆ to achieve precise and variable pressure regulation
◆ Application cooling capacity and wide operating range
◆ pulsation damping design
◆ Stainless steel to bellows
◆ "closed" brazing structure
◆ compact angle form of design, easy to install in any location
◆ provide a wide range of size of the bell mouth and outer diameter welding interface
◆ can be used for CFC, HCFC and HFC refrigerant
Regulating range 0.2 - 6.0 bar, factory setting 2 bar, max. working pressure 28 bar.
KVC type energy regulator is for regulating capacity of the compressor, to adapt to the evaporator load.
KVC type energy regulator is mounted on the refrigeration system of high / low pressure side of the road between the bypass pipe.
KVC helps to send the heat from high pressure side into the lower pressure side through the bypass line, to replace part of the load, so that the compressor suction pressure is not less than the minimum limit.
Flare:
034L0141
KVC 12 0,2 - 6,0 bar 12 mm 1/2 in 12 mm 1/2 in None 0,68
034L0142
KVC 15 0,2 - 6,0 bar 16 mm 5/8 in 16 mm 5/8 in None 1,25
welding/Solder:
034L0143
KVC 12 0,2 - 6,0 bar - 1/2 in - 1/2 in None 0,68 2,00 bar
034L0144
KVC 22 0,2 - 6,0 bar 22 mm 7/8 in 22 mm 7/8 in None 1,85 2,00 bar
034L0146
KVC 12 0,2 - 6,0 bar 12 mm - 12 mm - none 0,68 2,00 bar
034L0147
KVC 15 0,2 - 6,0 bar 16 mm 5/8 in 16 mm 5/8 in None 1,25 2,00 bar
Type | Rated capacity | Solder connection | Code no. | |||
R22 | R134a | R404A/R507 | R407C | ( inch) | ||
KVC12 | 7.6 | 4.8 | 6.9 | 8.4 | 1/2 | 034L0143 |
KVC15 | 14.9 | 9.4 | 13.6 | 16.4 | 5/8 | 034L0147 |
KVC22 | 19.1 | 12 | 17.4 | 21 | 5/7 | 034L0144 |
MODEL KVC | |||||||
Part Number | Model Number | Regulating | Connections | Rated Capacity (kW) | |||
Range kPa (psig) | R22 | R134a | R404A | R407C | |||
Capacity Regulator (hot gas Bypass) | |||||||
034L0141 | KVC12 | 20 to 600 (3 to 87) | 1/2" Fl.1 | 7.6 | 4.8 | 6.9 | 8.4 |
034L0042 | KVC15 | 5/8" Fl 1 | 14.9 | 9.4 | 13.6 | 16.4 | |
034L0043 | KVC12 | 1/2" ODS | 7.6 | 4.8 | 6.9 | 8.4 | |
034L0147 | KVC15 | 5/8" ODS | 14.9 | 9.4 | 13.6 | 16.4 | |
034L0144 | KVC22 | 7/8" ODS | 19.1 | 12 | 17.4 | 21 |
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2009
Total Annual:
50000000-100000000
Employee Number:
201~300
Ecer Certification:
Active Member
Star-Worths Refrigeration Co.,ltd as a professional refrigeration equipment company which combined Cold storage products manufacturing,after-sales service,technical consulting and many famous brands origional brand new refrigeration compressors&HVAC control... Star-Worths Refrigeration Co.,ltd as a professional refrigeration equipment company which combined Cold storage products manufacturing,after-sales service,technical consulting and many famous brands origional brand new refrigeration compressors&HVAC control...
Get in touch with us