Products
Manufacturer of a wide range of products which include 3.3kV / 6kV / 10kV Safe Variable Frequency Drive Mine Flame Proof And Intrinsica,660V/1140V Mine Flameproof And Intrinsically Safe Variable Frequency Drive VFD,FGPCS-2.50M/0.5...
MOQ:
Price:
Input phase | 3 phase |
Input frequency | 50Hz, 60Hz |
Input voltage | 3.3kV, 6.6kV, 10kV |
Allowable fluctuation | Power supply voltage ±20%, 50-60Hz±5%, voltage imbalance rate <3% |
Output rated voltage | 3.3kV, 6.6kV, 10kV |
Output rated current | 100% rated current continuous |
Place of Origin | China |
MOQ:
Price:
Input phase | 3 phase |
Input frequency | 50Hz, 60Hz |
Input voltage | 660V, 1140V |
Allowable fluctuation | Power supply voltage ±20%, 50-60Hz±5%, voltage imbalance rate <3% |
Rated voltage | The maximum output voltage is the same as the input supply voltage |
Rated current | 100% Rated current continuous |
Place of Origin | China |
MOQ:
Price:
Model | FGPCS-2.50M/0.5 |
Max DC input voltage | 1500V |
DC input voltage range | 730~1500V |
Max DC input current | 1936A*2 |
DC input channels | 1 |
Rated AC power (On-Grid) | 2500kVA@45℃ /2750kVA@30℃ |
Max AC current (On-Grid) | 2886A@45℃/3175A@30℃ |
Rated AC voltage (On-Grid) | 500V |
AC voltage range (On-Grid) | 425-550V |
Rated frequency range (On-Grid) | 50 Hz; 60Hz |
AC THDi (On-Grid) | <1.5% (Full load) |
Power factor (On-Grid) | >0.99(>20% load) |
Reactive power adjustment (On-Grid) | -1~+1 |
Rated AC voltage (Off-Grid) | 500V |
AC voltage range (Off-Grid) | 425-550V |
AC THDv (Off-Grid) | <1.5% (Linear load) |
Unbalanced load capacity (Off-Grid) | 100% |
Rated frequency range (Off-Grid) | 50 Hz; 60Hz |
Transformer isolation type | Dry type/ Oil type transformer isolated |
Transformer rated power | 2500kVA |
Transformer max power | 2750kVA |
LV/MV | 0.5kV/35kV |
Max efficiency | 99% |
Protection degree | IP65(converter), IP54(others) |
Running temperature | -30~+60℃ (>45℃ derating) |
Allowable humidity | 0~100% (No condensation) |
Altitude | 5000m (>2000m derating) |
Cooling mode | Intelligent forced air cooling |
Communication | RS485, CAN, Ethernet |
Dimension (W*H*D) | 7200×3000×3000mm (Dry type), 6200×2400×2600mm (Oil type) |
Weight | 15000kg (Dry type), 14000kg (Oil type) |
Model Number | FGPCS-2.50M/0.5 |
Place of Origin | China |
MOQ:
Price:
Max DC input voltage | 1500V |
DC input voltage range | 800~1500V |
Max DC input current | 1936A*2 |
DC input channels | 2 |
Rated AC power (On-Grid) | 2750kVA@45℃ /3025kVA@30℃ |
Max AC current (On-Grid) | 2886A@45℃/3175A@30℃ |
Rated AC voltage (On-Grid) | 550V |
AC voltage range (On-Grid) | 467.5~605V |
Rated frequency range (On-Grid) | 50 Hz; 60Hz |
AC THDi (On-Grid) | <1.5% (Rated power) |
Power factor (On-Grid) | >0.99(>20% load) |
Reactive power adjustment (On-Grid) | -1~+1 |
Rated AC voltage (Off-Grid) | 550V |
AC voltage range (Off-Grid) | 467.5~605V |
AC THDv (Off-Grid) | <1.5% (Linear load) |
Unbalanced load capacity (Off-Grid) | 100% |
Rated frequency range (Off-Grid) | 50 Hz; 60Hz |
Transformer isolation type | Dry type transformer isolated |
Transformer rated power | 2900kVA |
Transformer max power | 3190kVA |
LV/MV | 0.55kV/35kV |
Max efficiency | 99% |
Protection degree | IP65(converter), IP54(others) |
Running temperature | -30~+60℃ (>45℃ derating) |
Allowable humidity | 0~100% (No condensation) |
Altitude | 5000m (>2000m derating) |
Cooling mode | Intelligent forced air cooling |
Communication | RS485, CAN, Ethernet |
Dimension (W*H*D) | 6600×3000×2900mm (Dry type) |
Weight | 13400kg |
Model Number | FGPCS-2.75M/0.55 |
Place of Origin | China |
MOQ:
Price:
Max DC input voltage | 1500V |
DC input voltage range | 915~1500V |
Max DC input current | 1936A*2 |
DC input channels | 2 |
Rated AC power (On-Grid) | 3150kVA@45℃/3465kVA@30℃ |
Max AC current (On-Grid) | 2886A@45℃/3175A@30℃ |
Rated AC voltage (On-Grid) | 630V |
AC voltage range (On-Grid) | 535.5~693V |
Rated frequency range (On-Grid) | 50 Hz; 60Hz |
AC THDi (On-Grid) | <1.5% (Rated power) |
Power factor (On-Grid) | >0.99(>20% load) |
Reactive power adjustment (On-Grid) | -1~+1 |
Rated AC voltage (Off-Grid) | 630V |
AC voltage range (Off-Grid) | 535.5~693V |
AC THDv (Off-Grid) | <1.5% (Linear load) |
Unbalanced load capacity (Off-Grid) | 100% |
Rated frequency range (Off-Grid) | 50 Hz; 60Hz |
Transformer isolation type | Dry type transformer isolated |
Transformer rated power | 3300kVA |
Transformer max power | 3630kVA |
LV/MV | 0.63kV/35kV |
Max efficiency | 99% |
Protection degree | IP65(converter), IP54(others) |
Running temperature | -30~+60℃ (>45℃ derating) |
Allowable humidity | 0~100% (No condensation) |
Altitude | 5000m (>2000m derating) |
Cooling mode | Intelligent forced air cooling |
Communication | RS485, CAN, Ethernet |
Dimension (W*H*D) | 6600×3000×2900mm (Dry type) |
Weight | 13400kg(Dry type) |
Model Number | FGPCS-3.15M/0.63 |
Place of Origin | China |
MOQ:
Price:
Max DC input voltage | 1500V |
DC input voltage range | 1000~1500V |
Max DC input current | 1936A*2 |
DC input channels | 2 |
Rated AC power (On-Grid) | 3450kVA@45℃/3795kVA@30℃ |
Max AC current (On-Grid) | 2886A@45℃/3175A@30℃ |
Rated AC voltage (On-Grid) | 690V |
AC voltage range (On-Grid) | 586.5~759V |
Rated frequency range (On-Grid) | 50 Hz; 60Hz |
AC THDi (On-Grid) | <1.5% (Rated power) |
Power factor (On-Grid) | >0.99(>20% load) |
Reactive power adjustment (On-Grid) | -1~+1 |
Rated AC voltage (Off-Grid) | 690V |
AC voltage range (Off-Grid) | 586.5~759V |
AC THDv (Off-Grid) | <1.5% (Linear load) |
Unbalanced load capacity (Off-Grid) | 100% |
Rated frequency range (Off-Grid) | 50 Hz; 60Hz |
Transformer isolation type | Dry type transformer isolated |
Transformer rated power | 3650kVA |
Transformer max power | 4015kVA |
LV/MV | 0.69kV/35kV |
Max efficiency | 99% |
Protection degree | IP65(converter), IP54(others) |
Running temperature | -30~+60℃ (>45℃ derating) |
Allowable humidity | 0~100% (No condensation) |
Altitude | 5000m (>2000m derating) |
Cooling mode | Intelligent forced air cooling |
Communication | RS485, CAN, Ethernet |
Dimension (W*H*D) | 6600×3000×2900mm (Dry type) |
Weight | 13400kg (Dry type) |
Model Number | FGPCS-3.45M/0.69 |
Place of Origin | China |
MOQ:
Price:
Max DC input voltage | 1500V |
DC input voltage range | 1000~1500V |
Max DC input current | 1403A*2 |
DC input channels | 2 |
Rated AC power (On-Grid) | 2500kVA@45℃/2750kVA@30℃ |
Max AC current (On-Grid) | 2092A@45℃/2302A@30℃ |
Rated AC voltage (On-Grid) | 690V |
AC voltage range (On-Grid) | 586.5~759V |
Rated frequency range (On-Grid) | 50 Hz; 60Hz |
AC THDi (On-Grid) | <1.5% (Rated power) |
Power factor (On-Grid) | >0.99(>20% load) |
Reactive power adjustment (On-Grid) | -1~+1 |
Rated AC voltage (Off-Grid) | 690V |
AC voltage range (Off-Grid) | 586.5~759V |
AC THDv (Off-Grid) | <1.5% (Linear load) |
Unbalanced load capacity (Off-Grid) | 100% |
Rated frequency range (Off-Grid) | 50 Hz; 60Hz |
Transformer isolation type | Dry type transformer isolated |
Transformer rated power | 2750kVA |
Transformer max power | 3025kVA |
LV/MV | 0.69kV/35kV |
Max efficiency | 99% |
Protection degree | IP65(converter), IP54(others) |
Running temperature | -30~+60℃ (>45℃ derating) |
Allowable humidity | 0~100% (No condensation) |
Altitude | 5000m (>2000m derating) |
Cooling mode | Intelligent forced air cooling |
Communication | RS485, CAN, Ethernet |
Dimension (W*H*D) | 6650×3000×2800mm (Dry type) |
Weight | 13400kg (Dry type) |
Model Number | FGPCS-2.5M/0.69 |
Place of Origin | China |
MOQ:
Price:
Max DC input voltage | 1500V |
DC input voltage range | 730~1500V |
Max DC input current | 1936A |
DC input channels | 1 |
Rated AC power (On Grid) | 1250kVA@45℃/1375kVA@30℃ |
Max AC current (On Grid) | 1443A@45℃/1587A@30℃ |
Rated AC voltage (On Grid) | 500V |
AC voltage range (On Grid) | 425~550V |
Rated frequency range (On Grid) | 50Hz, 60Hz |
AC THDi (On Grid) | <1.5% (Full load) |
Power factor (On Grid) | >0.99(>20% load) |
Reactive power adjustment (On Grid) | -1~+1 |
Rated AC voltage (Off-Grid) | 500V |
AC voltage range (Off-Grid) | 425~550V |
AC THDv (Off-Grid) | <3% (Linear load) |
Unbalanced load capacity (Off-Grid) | 100% |
Rated frequency range (Off-Grid) | 50Hz, 60Hz |
Isolation type | Non-transformer isolated |
Max efficiency | 99% |
Protection degree | IP65 |
Running temperature | -30~+60℃(>45℃ derating) |
Allowable humidity | 0~100%(No condensation) |
Altitude | 5000m(>2000m derating) |
Cooling mode | Intelligent forced air cooling |
Communication | RS485, CAN, Ethernet |
Dimension(W*H*D) | 1000*2400*1500mm |
Weight | 1500kg |
Model Number | FGPCS-1.250M/0.5 |
Place of Origin | China |
MOQ:
Price:
Max DC input voltage | 1500V |
DC input voltage range | 800~1500V |
Max DC input current | 1936A |
DC input channels | 1 |
Rated AC power (On Grid) | 1375kVA@45℃/1512kVA@30℃ |
Max AC current (On Grid) | 1443A@45℃/1587A@30℃ |
Rated AC voltage (On Grid) | 550V |
AC voltage range (On Grid) | 467.5~605V |
Rated frequency range (On Grid) | 50Hz, 60Hz |
AC THDi (On Grid) | <1.5% (Full load) |
Power factor (On Grid) | >0.99(>20% load) |
Reactive power adjustment (On Grid) | -1~+1 |
Rated AC voltage (Off-Grid) | 550V |
AC voltage range (Off-Grid) | 467.5~605V |
AC THDv (Off-Grid) | <3% (Linear load) |
Unbalanced load capacity (Off-Grid) | 100% |
Rated frequency range (Off-Grid) | 50Hz, 60Hz |
Isolation type | Non-transformer isolated |
Max efficiency | 99% |
Protection degree | IP65 |
Running temperature | -30~+60℃(>45℃ derating) |
Allowable humidity | 0~100%(No condensation) |
Altitude | 5000m(>2000m derating) |
Cooling mode | Intelligent forced air cooling |
Communication | RS485, CAN, Ethernet |
Dimension(W*H*D) | 1000*2400*1500mm |
Weight | 1500kg |
Model Number | FGPCS-1.375M/0.55 |
Place of Origin | China |
MOQ:
Price:
Max DC input voltage | 1500V |
DC input voltage range | 915~1500V |
Max DC input current | 1936A |
DC input channels | 1 |
Rated AC power (On Grid) | 1575kVA@45℃/1732kVA@30℃ |
Max AC current (On Grid) | 1443A@45℃/1587A@30℃ |
Rated AC voltage (On Grid) | 630V |
AC voltage range (On Grid) | 535.5~693V |
Rated frequency range (On Grid) | 50Hz, 60Hz |
AC THDi (On Grid) | <1.5% (Full load) |
Power factor (On Grid) | >0.99(>20% load) |
Reactive power adjustment (On Grid) | -1~+1 |
Rated AC voltage (Off-Grid) | 630V |
AC voltage range (Off-Grid) | 535.5~693V |
AC THDv (Off-Grid) | <3% (Linear load) |
Unbalanced load capacity (Off-Grid) | 100% |
Rated frequency range (Off-Grid) | 50Hz, 60Hz |
Isolation type | Non-transformer isolated |
Max efficiency | 99% |
Protection degree | IP65 |
Running temperature | -30~+60℃(>45℃ derating) |
Allowable humidity | 0~100%(No condensation) |
Altitude | 5000m(>2000m derating) |
Cooling mode | Intelligent forced air cooling |
Communication | RS485, CAN, Ethernet |
Dimension(W*H*D) | 1000*2400*1500mm |
Weight | 1500kg |
Model Number | FGPCS-1.575M/0.63 |
Place of Origin | China |
Explore more categories
Get in touch with us
Leave a Message, we will call you back quickly!