Payment Terms | L/C, T/T |
Supply Ability | 30 sets per month |
Delivery Time | 45 working days |
Packaging Details | Nude with anti coil coating and plastic cover |
Voltage | 380V, 50Hz, 3 Phase |
Blade | at buyer's requirement |
Specification | 10*1.35*1.75m |
Punching | option |
Width | C80-300mm width changeable |
Thickness | 2-3mm |
Blade Material | C12MoV, Quenched |
Housing | H450 beam |
Material | Galvanized steel |
Profile Width | 90-600mm |
Shaft | 105mm |
Controlling System | PLC |
Punching Method | Hydraulic punching |
Roller Stations | 18 |
Shaft Material | 40Cr steel, quenched treament |
Brand Name | ZTRFM |
Model Number | PURLIN |
Certification | CE,SGS |
Place of Origin | China |
View Detail Information
Explore similar products
Chain Transimission U Automatic Roll Forming Machine Adjustable by PLC 7.5Kw
Building Material CZ Purlin Roll Forming Machine Metal Roll Former 11-16 Steps
Durable CZ Purlin Roll Forming Machine Dual Holes Punching 11 MAp Work Pressure
Single Station Steel Roll Forming Machine / C Channel Roll Forming Machine
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 30 sets per month |
Delivery Time | 45 working days | Packaging Details | Nude with anti coil coating and plastic cover |
Voltage | 380V, 50Hz, 3 Phase | Blade | at buyer's requirement |
Specification | 10*1.35*1.75m | Punching | option |
Width | C80-300mm width changeable | Thickness | 2-3mm |
Blade Material | C12MoV, Quenched | Housing | H450 beam |
Material | Galvanized steel | Profile Width | 90-600mm |
Shaft | 105mm | Controlling System | PLC |
Punching Method | Hydraulic punching | Roller Stations | 18 |
Shaft Material | 40Cr steel, quenched treament | Brand Name | ZTRFM |
Model Number | PURLIN | Certification | CE,SGS |
Place of Origin | China | ||
High Light | Strucad Purlin Roll Forming Machine ,Sigma Purlin Roll Forming Machine ,Tekla Structures Purlin Roll Forming Machine |
Sigma Purlin System Roll Forming Machine
It offers solutions from 120mm to 400mm with gauges from 1.2mm to 3.2mm, all fully supported by Strucad and Tekla Structures detailing packages, which also generate
Cam Data to reduce the risk of potential errors, and remove the need for the time consuming creation of drawings.
Our new Sigma Beam Purlin generates excellent strength to weight ratio improvements, not to mention the reduction of accessory requirements in common design criteria, saving the additional cost of components and erection time on site. This product has been launched using S450 material rather than the existing industry standard S390, and the Sigma Beam Purlin used with our standard range of C sections as side rails offers practical, flexible and economical solutions for all your purlin and rail needs.
Product Range
Here is a profile for your reference:
The system is designed primarily for use, on roofs, as secondary sheeting support. Bay widths up to 15m and maximum roof slope of 25 degrees.Sigma sections are manufactured by cold roll forming pre-hot dipped galvanised steel, grade S450, having a minimum yield stress of 450N/mm2 Section properties have been calculated in accordance with Eurocode 3, BS EN 1993-1-3:2006. Calculation of ultimate loads and working deflections are based on the results of full scale testing and finite element analysis. The top flange of the purlin must have adequate restraint provided by robust steel sheeting (or similar) fixed directly to the top flange. The steel has an external galvanised coating Z275, giving an approximate coating thickness of 20 microns each side.
Sleeve Assembly and Cleat Details
Sleeves are required to provide structural continuity of the purlin section across the supporting rafter. All sleeves are of similar length and longitudinal drillings consistent. Sleeve thickness is dependent on purlin thickness - see table.
The most cost effective purlin system, in terms of material content and number of components to erect, is the double span butt system.
Purlin Cleat Details
Standard Sleeve Dimensions
Note: Where Albion standard cleats are not provided, take care to ensure that sufficient clearance is provided from the underside of the purlin to the top of the rafter for the installation of the sleeve.
Sigma Standard Drillings
Standard drillings are shown below for the sigma purlin range.14mm diameter sleeve and cleat connection holes, to suit M12 bolts, are used for the 200, 225 and 240 series sigma, whilst 18mm
diameter, for M16 bolts, are used for the 265 and 300 deep sigmas. All connecting bolts to be grade 8.8. Speed fix holes, where required, are 14mm wide * 20mm rectangular. Holes to suit intermediate span angle struts are 14mm diameter for M12 grade 4.6 bolts. 14mm diameter flange holes provided if required. Maximum section length 16m.
Sigma Purlin System Roll Forming Machine
Sigma Purlin Systems and Joining Layouts
The sigma purlin shape provides an efficient, robust profile that suits both short and long span conditions. In most cases of popular building type sag rods are not required (subject to wind uplift conditions).Sleeves are required to provide continuity to the purlin section across the supporting rafters. The most popular system, double spanning, has been specifically developed to minimise the number of sleeves, thus reducing the number of components and resulting in savings in installation time and component cost. The sleeve details have also been considered in terms of simplicity and duplication. All sleeves are the same length with identical longitudinal dimensions, uniformity reducing the chance of errors.
Single Span Butt System
The simplest of the purlin systems. Use where design conditions dictate that no connecting sleeves can be used, i.e. purlin within depth of rafter.
Double Span Butt System
Use with 200, 225, and 240 Series
The most popular purlin system combining double span lengths with a minimum of jointing sleeves. The sleeved system can be used for buildings with two bays or more and combines a cost effective solution with ease of detailing. Bay widths are limited to 8m (Maximum purlin lengths 16m)
Sigma Purlin Systems and Joining Layouts
Single Span Sleeved System
Heavy End Bay System An alternative to the double span system and suitable for all bay sizes.May be used with all Sigma Sections. Where purlins are required to be single spanning, but still maintaining continuity over the rafters, the single span sleeved system can be employed. With additional sleeves, as shown, the ultimate capacities of the double span sleeve system can be realised. Use also where access may be limited, i.e. purlin lifted in from below.
Heavy End Bay System
Suitable on buildings of 5 bays or more Single span arrangement (All Sigma Sections)
Speed Fix Anti-Sag Bars
Albion speed fix sag bars provide an effective restraint to the purlin both during the cladding operation and under wind uplift (reversal) conditions. The spring loaded clip fixing system makes installation quick and easy. Speed fix should be fixed as shown below
Anti-Sag bars serve two main purposes:
• To stop the purlin twisting during erection. (Once sheeting is fixed the purlin derives a large measure of stiffness from the roof membrane).
• To provide lateral restraint to the bottom flange under uplift conditions.
Note:These details apply to roof slopes up to and including 25º. For roof slopes greater than 25ºconsult our Technical Department.
Speed Fix are manufactured from 1.6mm thick pre-hot dipped galvanised mild steel and cold formed into a channel section 15mm deep * 12mm wide.Each end is notched to locate in the standard pre punched rectangular holes at mid span or third points.Alternative apex ties are manufactured from 12mm diameter allthread, zinc plated finish.
Angle Strut Purlin Restraints
For larger spans or deeper sections, angle struts are used to provide stability during the cladding operation and under wind reversal conditions. Angle struts are manufactured from 45*45*2mm pre-hot dipped galvanised angle. Holes in the struts are all 14mm diameter to suit M12 bolts.
Anti-Sag Minimum Requirements
Apex ties must be used on all spans over 4m on duopitch roofs.
Long Roof Slopes
Where roof slope exceeds 20m, intermediate span restraint is required to resist down slope loadings. This is provided by a strut and tie system as shown.
Anti-Sag Minimum Requirements
Mono Pitch Roofs
On mono pitch roofs, strut and tie system is required at the apex, to resist down slope loadings
Flat Roofs
(Slope less than 3º)
For very low pitch or flat roofs the Sigma purlins are installed in facing pairs, as shown below Angle struts provided at mid span for spans in excess of 4m and third span positions for span in excess of 7.1m.
Cleader Angles & Rafter Stays
Rafter Stays/Column Stays
Rafter Stays are manufactured from pre-hot dipped galvanised mild steel and cold roll formed into angle section 45mm x 45mm x 2.0mm thickness.
Typical Details
Purlin Gable Overhang/Cantilever Detail
Gable Verge Detail
Further applications of Albion Sigma beams
Mezzanine Floors
The Sigma profile is ideally suited to provide structural support to lightweight floors.
Sigma Purlin System Roll Forming Machine
Company Details
Business Type:
Manufacturer,Exporter,Trading Company
Year Established:
2014
Total Annual:
50000000-6000.0000
Employee Number:
20~50
Ecer Certification:
Verified Supplier
we can manufacture contains: roofing sheet machine, CZ purlin machine, light steel gauge machine, metal embossing machine, door system forming machine, ceiling system machine, pipe welding machine, slitting and cut to length machines, rack system machines, floor decking machine, stone coated steel r... we can manufacture contains: roofing sheet machine, CZ purlin machine, light steel gauge machine, metal embossing machine, door system forming machine, ceiling system machine, pipe welding machine, slitting and cut to length machines, rack system machines, floor decking machine, stone coated steel r...
Get in touch with us
Leave a Message, we will call you back quickly!