Payment Terms | T/T in advance, LC AT SIGHT |
Supply Ability | 10 pcs per month |
Delivery Time | 30 working days after received your payment |
Packaging Details | Solid plywood case suitable for long distance transportation |
Model Name | MD-0.6V veterinary autoclave |
Capacity | 600L |
Inner chamber | 600*600*1670mm |
Outer dimension | 1200*2000*2010mm |
Sterilization temperature | 105 to 134 degree |
Sterilization auxiliary | Sterilization trays or baskets |
Chamber material | 304 or 316L |
Door type | Single or double vertical sliding door |
Brand Name | Medpharm |
Model Number | MD-0.6V |
Certification | CE/SGS |
Place of Origin | China |
View Detail Information
Explore similar products
Colored Touch Screen Front Loading Veterinary Autoclave Compliance With cGMP
PID Control System Hot Air Oven With Accurate Temperature Sensor For Veterinary
Muti level Password Access Veterinary Autoclave With Integral Clean Steam
Digital Display Veterinary Bench-top Autoclave With Door Safety Locking System
Product Specification
Payment Terms | T/T in advance, LC AT SIGHT | Supply Ability | 10 pcs per month |
Delivery Time | 30 working days after received your payment | Packaging Details | Solid plywood case suitable for long distance transportation |
Model Name | MD-0.6V veterinary autoclave | Capacity | 600L |
Inner chamber | 600*600*1670mm | Outer dimension | 1200*2000*2010mm |
Sterilization temperature | 105 to 134 degree | Sterilization auxiliary | Sterilization trays or baskets |
Chamber material | 304 or 316L | Door type | Single or double vertical sliding door |
Brand Name | Medpharm | Model Number | MD-0.6V |
Certification | CE/SGS | Place of Origin | China |
High Light | Veterinary Medical Equipment ,Veterinary Clinic Equipment |
Effluent Decontamination Veterinary Autoclave Bulk Steam Sterilization For Animal Labs
Specification
Model | Chamber Size | Overall Size | Net Weight | Steam | Water | Power |
W*H*D mm | W*H*D mm | Kg | Kg/cycle | Kg/cycle | KVA | |
MD-0.11V | 400*400*700 | 1000*1800*1040 | 650 | 14 | 15 | 2 |
MD-0.16V | 400*400*1000 | 1000*1800*1340 | 700 | 16 | 20 | 2 |
MD-0.20V | 400*400*1300 | 1000*1800*1640 | 750 | 18 | 25 | 2 |
MD-0.24V | 600*600*670 | 1200*2000*1010 | 800 | 20 | 30 | 2 |
MD-0.30V | 600*600*840 | 1200*2000*1180 | 850 | 22 | 35 | 2 |
MD-0.36V | 600*600*1000 | 1200*2000*1340 | 900 | 25 | 40 | 2 |
MD-0.45V | 600*600*1250 | 1200*2000*1590 | 980 | 27 | 50 | 2 |
MD-0.60V | 600*600*1670 | 1200*2000*2010 | 1100 | 30 | 60 | 3 |
Program Parameter
Cycle name | Further details | Application |
Instruments/Tools | 3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. | Solid materials to be sterilized: |
Clothing | 3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min. | Materials to be sterilized from which air can’t be easily displaced |
User Programmable | All preset parameters can be reset; Multiple customized programs can be set and stored by user. | Customized |
Test programs | ||
B-D Test | 3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min. | Test program |
Vacuum Leak Test | Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect. | Test program |
Features
Description
Feature of the veterinary autoclave is the control of the sterilization phase according to a pressure signal, rather than temperature. Obviously, the temperature readout varies as a function of the position of the sensor, whilst the pressure is uniform throughout the chamber.
However, process control is performed by reading in the chamber (and from inside the product) temperature signals whose match with the pressure value, as constantly verified by the controller, demonstrates that the autoclave is operating correctly.
This principle, in saturated-steam conditions (when there is a two-way T/P correspondence) allows to obtain uniformities in sterilization temperature which are far better than the currently required level of ±1.0 °C.
Applications
Competitive Advantage
Effluent Decontamination.
Available on gravity and pre-vacuum units. Retains liquid effluent, if any, within the chamber for the duration of the sterilization cycle. Aerosol effluent passes through a 0.2 micron hydrophobic HEPA filter with >99.999% efficiency; the filter is located within the chamber and is sterilized in situ to eliminate the need for disposal after each cycle. The filter is easily replaced by the user when required without special tools or service personnel.
Company Details
Business Type:
Manufacturer,Trading Company
Ecer Certification:
Verified Supplier
MEDPHARM Company team is committed to providing quality sterilization products, service, parts and maintenance training at significant savings. From customized parts packages to turnkey&n... MEDPHARM Company team is committed to providing quality sterilization products, service, parts and maintenance training at significant savings. From customized parts packages to turnkey&n...