Delivery Time | About one week |
Payment Terms | T/T |
Packaging Details | 1 Box (24pcs/bag) |
Disinfecting Type | Far Infrared |
Size | all |
Material | pin gold plated ,TPU Cable |
Instrument classification | Class II |
Color | Gray |
Length | 0.9m |
OEM | OEM Service Accepted |
Type | Disposable Adult,Pediatric,Infant,Neonate Sensor |
Place of Origin | China |
Brand Name | Med Accessories |
Model Number | M15D series |
Certification | CE,ISO,SFDA |
View Detail Information
Explore similar products
Medical Adult Disposable Spo2 Sensor Adhesive Durable For Main Brand Monitors
Multipurpose Disposable Spo2 Probe Medical Pediatric Pulse Oximeter Adhesive
Adult Disposable Spo2 Sensor Adhesive Durable For Main Brand Monitors Compatible
Med Accessories Factory Adhesive Disposable Pulse Oximeter Finger Probe Length
Product Specification
Delivery Time | About one week | Payment Terms | T/T |
Packaging Details | 1 Box (24pcs/bag) | Disinfecting Type | Far Infrared |
Size | all | Material | pin gold plated ,TPU Cable |
Instrument classification | Class II | Color | Gray |
Length | 0.9m | OEM | OEM Service Accepted |
Type | Disposable Adult,Pediatric,Infant,Neonate Sensor | Place of Origin | China |
Brand Name | Med Accessories | Model Number | M15D series |
Certification | CE,ISO,SFDA | ||
High Light | Non Woven Disposable Spo2 Sensor ,Adult Disposable Spo2 Sensor ,0.9m Adult Spo2 Sensor |
Manufacturer | OEM Part # |
---|---|
M | 1859 (LNCS Adtx) Also 2320,1860,2328 are available. |
Manufacturer | Model |
---|---|
Bitmos | sat 800, sat 801, sat 805, sat 816, satPuls |
Datex Ohmeda | Giraffe Infant Warmer, S/5 |
Draeger | Infinity Delta, Infinity Delta XL, Infinity Kappa, Infinity M540, Narkomed 6400 |
GE Healthcare > Corometrics | 128, 250, 250cx, TRAM 450SL |
GE Healthcare > Critikon > Dinamap | Carescape B650, Carescape B850, Carescape V100, Carescape V100 with M technology, Dinamap ProCare with M Pro 1000, Pro 300V2, ProCare 300, ProCare Ausculatory 400, ProSeries V2, V300 |
GE Healthcare > Marquette | 8000 e Eagle 1000, Dash 2000, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Dash Series, Eagle, PDM Module, Procare B40, SOLAR, Smk SMV, Solar 7000, Solar 8000, Solar 8000M, Solar Series, TRAM Modular, Tram 451, i/9500, i/9500 (Tram 451N5/851N5), x50SL Series |
Invivo | Escort II OPT30 Prism, T8 |
M | All, Pronto-7, Rad-5, Rad-57, Rad-8, Rad-87, Radical-7 |
Mennen | Horizon XVu |
Mindray > Datascope | Beneheart D6, DPM4, DPM6, DPM7, Duo, EPM4, MEC 12, MPM, PM 6000, PM 6800, PM 7000, PM 8000, PM 9000, Passport 12, Passport 2, Passport 2LT, Passport 8, Passport V, Passport XG, Spectrum, Spectrum OR, Accutor V, Accutorr 3, Accutorr 7, Accutorr Plus, Accutorr V, BeneView T1, BeneView T5, BeneView T8, BeneVision TMS60, BeneVision TMS80 |
Penlon InterMed | All |
Ph* | M3002A, M3002A MMS X2, M3500B, M4735A, M8102A, M8102A MP2, M8105A MP5, M8105AS, MP 30, SureSigns VS2, SureSigns VS3, VM4,Heartstream XL, IntelliVue FAST-SpO2, IntelliVue MP70, M1020B, M2601A, M3000A, M3001A, M3001A A03, M3001A A03C06, M3001A A03C12, M3001A A03C18 |
Respironics | Alice 5 |
Stryker > Medtronic > Physio Control | Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E |
Welch Allyn | Spot Vital Signs 42MOB, Spot Vital Signs 42MTB-E1, Spot Vital Signs lXi,1500, 45NE0-E1 LX, 53S00, 53S0P, 53ST0, 53STP, Propaq CS, Propaq LT |
Zoll | E Series, M Series, R Series, X Series |
1. Product Name:
Non-woven Adult/Neonate 1859 M 0.9m Disposable Spo2 Sensor
2.Technical Parameters:
Red 660nm±3 mm;
Infrared 905nm±5 mm
*Operating temperature range: 0℃ to 30℃
*Storage and transportation temperature range :0℃to 30℃
*Relative humidity: 0-70%
*Atmospheric pressure: 850 to 1060 HPa
* SpO2 Range (90%-100%) ---Accuracy ±2 %
*SpO2 Range (70%-90%) ---Accuracy ±3 %
*SpO2 range (<69%) ---no specified
*Pulse rate range: 20-250bpm----Accuracy ±2 bpm
3. operation instructions
1.Connect the sensor cable to the adaptor cable that fits your oximeter. Then turn on the oximeter and verify proper operation
2.Select the sensor site on the patient. The preferred sensor sites are the index finger for adult and children, the great toe for infants, and on the foot below
the toes for neonate.
3.Apply the sensor on the patient:
Position the emitter and detector directly opposite each other.
Apply the sensor firmly but not too tightly. And then fix the sensor with Velcro non-adhesive tape.
4.Visually monitor the sensor site to ensure the integrity of the skin.
Company Details
Business Type:
Manufacturer
Year Established:
2018
Total Annual:
1000000-5000000
Employee Number:
100~200
Ecer Certification:
Verified Supplier
Med Accessories Technology Dongguan Co., Ltd. is a design-integrated, production-oriented enterprise. The company was established in 2018 and operates within a 2,000 square meter facility. Located in the renowned and picturesque city of Songshan Lake, Dongguan, Guangdong. Our company sp... Med Accessories Technology Dongguan Co., Ltd. is a design-integrated, production-oriented enterprise. The company was established in 2018 and operates within a 2,000 square meter facility. Located in the renowned and picturesque city of Songshan Lake, Dongguan, Guangdong. Our company sp...
Get in touch with us
Leave a Message, we will call you back quickly!