Payment Terms | T/T |
Supply Ability | 500 sets/ month |
Delivery Time | 5-30 work days |
Packaging Details | Multiple packaging |
Product Name | Hybrid Solar And Wind Power Generation |
Wind Turbine | 600W, 1000W, 1500W, 2000W |
Solar Panel | According to configuration |
Voltage | 48V |
Battery | Lead-acid batteries or lithium batteries |
Battery Voltage | 2V, 6V, 12V |
Power Supply | Continuous power supply |
System | Communication Base Station |
Brand Name | URILIC |
Model Number | Communication Base Station Power Supply System |
Certification | ISO9001,CE,UL,IEC |
Place of Origin | China |
View Detail Information
Explore similar products
Mobile Lighting Combined Solar And Wind Energy System 20 Years Design Life
Energy Saving Hybrid Solar And Wind Power Generation Weather Monitoring
Industrial Safety Hybrid Solar Wind Power Generation System Wind Turbine
Commercial Hybrid Solar And Wind Power Generation Residential Vertical Wind
Product Specification
Payment Terms | T/T | Supply Ability | 500 sets/ month |
Delivery Time | 5-30 work days | Packaging Details | Multiple packaging |
Product Name | Hybrid Solar And Wind Power Generation | Wind Turbine | 600W, 1000W, 1500W, 2000W |
Solar Panel | According to configuration | Voltage | 48V |
Battery | Lead-acid batteries or lithium batteries | Battery Voltage | 2V, 6V, 12V |
Power Supply | Continuous power supply | System | Communication Base Station |
Brand Name | URILIC | Model Number | Communication Base Station Power Supply System |
Certification | ISO9001,CE,UL,IEC | Place of Origin | China |
High Light | wind turbine and solar panel hybrid system ,wind turbine solar panels hybrid system |
Mobile Communication Base Station Equipment Hybrid Solar And Wind Power Generation
Base station power supply system is one of the supporting systems for mobile main equipment and transmission equipment, involving power.
Many professional knowledge such as mechanics, chemistry, electronic communication and automatic control technology, computer application and so on. The purpose of its maintenance work is to ensure that communication equipment can obtain sustained, stable and reliable energy, to provide a normal operating environment for communication equipment, and to ensure the safety of the system. In this regard, maintenance personnel need to have certain professional skills.
There are many kinds of power supply equipment, which are greatly influenced by external factors. If the maintenance is not effective, the overall failure rate of the equipment will be very high. The power environment monitoring system will lose its effectiveness, the operation cost is high, and the base station is not safe. In order to reduce operating costs and prevent the early abandonment of batteries, this paper analyses the electric environment of base station and the key points of power maintenance, and puts forward solutions.
Application Factors of Mobile Communication Base Station Equipment Hybrid Solar And Wind Power Generation
In the whole communication industry, the environment of mobile communication base station is more complex. Due to the restriction of the environment conditions of base station, the requirements of construction and configuration are different, and maintenance requirements are different. For example, many base stations are built on high buildings or high mountains. Objectively speaking, most of the urban power environment of base stations is not as high as that of exchange bureaus, but the quality of batteries is higher, which adds many difficulties to the configuration, maintenance and management of batteries. If improper maintenance, it will cause the early failure of batteries.
Battery:
Battery maintenance is the focus of the whole power supply maintenance work. All power supply maintenance is carried out around this work. Generally speaking, the key to the maintenance of VRLA batteries is to control the temperature of the environment and the charging and discharging of the batteries. Therefore, controlling the charging and discharging of the batteries is an important link in the maintenance of the batteries. Battery charging is divided into floating charging and balanced charging. The so-called floating charge refers to the parallel operation of storage battery and switching power supply when the city electricity is normal. The output voltage of switching power supply meets the requirements of battery manufacturers, generally 2.23V/unit, which is used to meet the needs of self-discharge and oxygen cycle of batteries. By definition, floating charge voltage can only meet the needs of self-discharge and oxygen cycle of battery, and can not be used as supplementary charge after battery discharge. Supplementary charging of batteries is accomplished by balanced charging of switching power supply. When charging equally, the charging voltage is increased to 2.35V~2.40V/battery, and the battery is charged with current less than or equal to 0.10C10A. The control of charging process is realized by setting the switching power supply and intelligent control of the switching power supply. In daily maintenance, it can be checked regularly by the power environment monitoring system to prevent the change of rectifier parameters and battery damage.
Hot-selling Maglev Vertical Axis Wind Turbine
Items | 60024/48 | 100024/48 |
Rated power | 600W | 1000W |
Dimension | Ø1100/1250 | Ø1500/1760 |
Weight | 32kg / 35kg | 55 kg / 57kg |
Blade material | Aluminum Alloy | Aluminum Alloy |
Blade quantity | 3 | 3 |
Swept area ㎡ | 1.2 | 1.8 |
Min starting wind speed | 1.3m/s | 1.5 m/s |
Cut-in wind speed | 2 7m/s | 3.5m/s |
Rated wind speed | 12m/s | 13m/s |
Cut-off wind speed | 15m/s | 15m/s |
Survival wind speed | 65m/s | 60m/s |
Generator type | AC,3Phases | AC,3Phases |
Controller Output Voltage | 24V/48V | 24V/48V |
Controller Braking System | 3-phase short circuit by NFB brake | 3-phase short circuit by NFB brake |
Ambient Temperature | -40~50 ℃ | -40~50 ℃ |
Noise | Noisy from National Machinery Quality Inspection Centre at 12m/s : <40db |
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2018
Total Annual:
5000-8000
Employee Number:
>100
Ecer Certification:
Active Member
Shenzhen URILIC Energy Technology Co., Ltd. is located in one of the most developed cities in China – Shenzhen. The corporation boasts great geological advantages as well as abundant sources, which enables the corporation construct an excellent scientific resea... Shenzhen URILIC Energy Technology Co., Ltd. is located in one of the most developed cities in China – Shenzhen. The corporation boasts great geological advantages as well as abundant sources, which enables the corporation construct an excellent scientific resea...
Get in touch with us
Leave a Message, we will call you back quickly!