Payment Terms | T/T, Western Union,Paypal,L/C |
Supply Ability | 50000pcs/month |
Delivery Time | 5-35days |
Packaging Details | 1pcs/gift box, 30~50pcs/ctn; package size: 10X5X3cm; gross weight:0.500kg |
Model | CHX-DM021 |
DC voltage | 60V |
Resolution | 0.001V |
Input impedance | 10MΩ |
Maximum input voltage | 600V DC or 600V AC (rms) |
Frequency range: | 40 ~ 1000Hz True RMS |
product name | Digital Multimeter |
Ambient temperature | 23 ± 5 ℃ |
Brand Name | CHX |
Model Number | CHX-DM021 |
Certification | CE, RoHS |
Place of Origin | CHINA |
View Detail Information
Explore similar products
10MΩ 600V Digital Display Multimeter Overload Protection
Backlight Digital Smart Multimeter 60mA 600mA 6A 10A
Measuring Data Hold Digital Smart Multimeter 1A 10A 100nF True RMS Multimeter
10MΩ 0.01V Portable Digital Multimeter Professional Measuring Instruments
Product Specification
Payment Terms | T/T, Western Union,Paypal,L/C | Supply Ability | 50000pcs/month |
Delivery Time | 5-35days | Packaging Details | 1pcs/gift box, 30~50pcs/ctn; package size: 10X5X3cm; gross weight:0.500kg |
Model | CHX-DM021 | DC voltage | 60V |
Resolution | 0.001V | Input impedance | 10MΩ |
Maximum input voltage | 600V DC or 600V AC (rms) | Frequency range: | 40 ~ 1000Hz True RMS |
product name | Digital Multimeter | Ambient temperature | 23 ± 5 ℃ |
Brand Name | CHX | Model Number | CHX-DM021 |
Certification | CE, RoHS | Place of Origin | CHINA |
High Light | 60V Pocket Size Digital Multimeter ,10MΩ Pocket Size Digital Multimeter ,0.001V Digital Multimeter Tester |
Newest Ultra-Thin Pocket Size Digital Multimeter Relative Humidity <75%
Product warranty instructions
Product certification is your instrument in the use of failure, seeking repair services must have, and then you purchase the invoice at the same time to be effective.
1) When your multimeter in use fails, please contact our maintenance department as soon as possible, consultation, so as not to delay your use and warranty period.
2) The product of the Company from the date of purchase from the warranty service. In the event of failure during the warranty period, the company professionals to confirm the reasons for the failure of non-users, the company free warranty service.
3) If the warranty period is exceeded, the cost will be charged (repair fee + component fee).
4) Even during the warranty period, maintenance fees are charged in the following cases.
⑴ due to improper use of the user or accidental disaster events and damage to the components and burn the circuit board.
⑵ non-professional staff of the company open shell, inspection, modification.
⑶ failure to comply with the instructions specified in the operation.
⑷ not the company's products do not maintain repair.
⑸ due to maintenance caused by postage, transportation and other users themselves.
⑹ multimeter battery, table pen, temperature probe and other functional accessories and supplies are not free warranty list.
Technical indicators
Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
3.2.1 True rms zero input
3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.
3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.
3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.
3.2.2 DC voltage
Range | Resolution | Accuracy |
6V | 0.001V | ±(0.5% of reading + 5 words) |
60V | 0.01V | |
600V | 0.1V | ±(0.8% of reading + 5 words) |
- Input impedance: 10MΩ
- Maximum input voltage: 600V DC or 600V AC (rms)
Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
3.2.3 AC voltage
Range | Resolution | Accuracy |
6V | 0.001V | ±(0.8% of reading + 3words) |
60V | 0.01V | |
600V | 0.1V | ±(1.0% of reading + 10words) |
- Input impedance: 10MΩ
- Maximum input voltage: 600V AC (RMS) or 600V DC
- Frequency range: 40 ~ 1000Hz True RMS
Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
3.2.4 Alternating current
Range | Resolution | Accuracy |
600.0uA | 0.1uA | ±(1.5% of reading +10words) |
6000uA | 1uA | |
60.00mA | 0.01mA | |
600.0mA | 0.1mA | |
6A | 0.001A | ±(2.5% of reading +10words) |
10A | 0.01A |
- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
- Frequency response: 40Hz ~ 1000Hz True RMS.
3.2.5 DC
Range | Resolution | Accuracy |
600.0uA | 0.1uA | ±(1.0% of reading +5words) |
6000uA | 1uA | |
60.00mA | 0.01mA | |
600.0mA | 0.1mA | |
6A | 0.001A | ±(2.0% of reading +10words) |
10A | 0.01A |
- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
3.2.6 Frequency
Range | Resolution | Accuracy |
9.999Hz | 0.001Hz | ±(1.0% of reading +3words) |
99.99Hz | 0.01Hz | |
999.9Hz | 0.1Hz | |
9.999kHz | 0.001kHz | |
99.99KHZ | 0.01kHZ | |
999.9KHZ | 0.1KHZ | |
9.999MHZ | 0.001MHZ |
- Overload protection: 250V DC or AC (rms)
- Input voltage range: 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)
3.2.7 Duty cycle
Range | Resolution | Accuracy |
0.1 – 99.9% | 0.1% | ± 3.0% |
- Frequency response: 10 ~ 10MHz
- Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)
- Maximum input voltage: 250V AC (rms)
Resistance
Range | Resolution | Accuracy |
600W | 0.1W | ±(0.8% of reading +3words) |
6kW | 0.001kW | |
60kW | 0.01kW | |
600kW | 0.1kW | |
6MW | 0.001MW | ±(1.2% of reading +3words) |
60MW | 0.01MW |
- Open circuit voltage: approx. 1.0V
- Overload protection: 250V DC or AC (rms)
Transistor test
Range | Description | Test Conditions |
hFE | The display reads the approximate value of hFE(0~1000) | Base current of about 10uA; Vce about 2.8V |
Capacitance
Range | Resolution | Accuracy |
9.999nF | 0.001nF | ±(4.0% of reading +3words) |
99.99nF | 0.01nF | |
999.9nF | 0.1nF | |
9.999mF | 0.001mF | |
99.99mF | 0.01mF | |
999.9mF | 0.1mF | |
9.999mF | 0.001mF | ±(5.0% of reading +3words) |
99.99mF | 0.01mF | Not calibrated |
- Overload protection: 250V DC or AC (rms)
Temperature test
Range | Accuracy | Resolution |
-20℃-300℃ | ±(1.0%+4d) | 1℃ |
301℃-1000℃ | ±(1.9%+5d) | 1℃ |
-4℉-600℉ | ±(1.2%+6d) | 1℉ |
601℉-1832℉ | ±(1.9%+6d) | 1℉ |
- Overload protection: 250V DC or AC (rms)
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
3000000-8000000
Employee Number:
80~100
Ecer Certification:
Active Member
Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ... Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ...
Get in touch with us
Leave a Message, we will call you back quickly!