Payment Terms | T/T, Western Union,Paypal,L/C |
Supply Ability | 50000pcs/month |
Delivery Time | 5-35days |
Packaging Details | 1pcs/gift box, 30~50pcs/ctn |
Mode | CHX-CM006 |
Display | LCD |
AC voltage range | 450V |
Resolution | 0.1V |
Accuracy | ±(1.2% + 5) |
Environment temperature | 23±5℃ |
Relative humidity | <75% |
product name | Digital Clamp Multimeter |
Brand Name | CHX |
Model Number | CHX-CM006 |
Certification | CE, RoHS |
Place of Origin | CHINA |
View Detail Information
Explore similar products
600V 750V Digital Clamp Multimeter 9.999Hz 99.99Hz With LCD Display
60A 0.01A Digital Clamp Tester , 400A AC DC Clamp On Amp Meter
400A AC Digital Clamp Multimeter Voltage Tester 1999 Display 190g
Data Keep Clamp On Digital Multimeter 190g 10MW 184.0×66.0×32.5mm
Product Specification
Payment Terms | T/T, Western Union,Paypal,L/C | Supply Ability | 50000pcs/month |
Delivery Time | 5-35days | Packaging Details | 1pcs/gift box, 30~50pcs/ctn |
Mode | CHX-CM006 | Display | LCD |
AC voltage range | 450V | Resolution | 0.1V |
Accuracy | ±(1.2% + 5) | Environment temperature | 23±5℃ |
Relative humidity | <75% | product name | Digital Clamp Multimeter |
Brand Name | CHX | Model Number | CHX-CM006 |
Certification | CE, RoHS | Place of Origin | CHINA |
High Light | 50Hz RMS Digital Multimeter ,60Hz Digital DC Voltmeter ,60Hz Clamp On Multimeter |
50Hz ~60Hz Digital Clamp Multimeter Relative measurement
Maintenance
1.4.1 Please do not attempt to test lead the shell to adjust or repair instrument, this operation can only be fully understood by technicians
1.4.2 Before test leading the instrument bottom shell and the battery cover, should be removed the test lead from the measured line test lead
1.4.3 In order to avoid false readings may cause electric shock, when the instrument display “” symbol,
The battery should be replaced immediately.
1.4.4 Use a damp cloth and a mild detergent to clean the instrument; do not use abrasive detergents or solvents.
1.4.5 The instrument when not in use should turn off the power,
1.4.6 If you do not use a meter long time, the battery should be removed to prevent damage to the instrument.
Description
- The instrument is an professional measuring instrument with liquid crystal display and a back light source. The user readings in easily. Single hand operation with overload protection and low battery indicator. For professional, factory, school, lovers or family use, is an ideal Multi-function instrument.
- Used for AC DC voltage,AC current, frequency, resistance, capacitance measurement and the on-off circuit, measurement, temperature measurement .
- Automatic range
- Data keep
- Auto power off
- Relative measurement
Technical indicators
Environment temperature:23±5℃ Relative humidity:<75%
3.2.1 AC Current
Range | Resolution | Accuracy |
6A | 0.001A | ±(3.0% + 20) |
60A | 0.01A | ±(2.5% + 8) |
600A | 0.1A | ±(2.5% + 10) |
-Min input current:0.01A AC
- Max input:600AC
- Frequency:50Hz ~60Hz
- When ac current is measured, the meter automatically opens an internal low-pass filter to filter out high-frequency current.
3.2.2 DC voltage
Range | Resolution | Accuracy |
6V | 0.001V | ±(0.5% + 3) |
60V | 0.01V | |
500V | 0.1V | ±(0.8% + 5) |
- Min/ input voltage:0.9V DC
- Input impedance:10MW
-Maximum/ input voltage:500V AC (Effective value)OR 500V DC
3.2.4 AC voltage
Range | Resolution | Accuracy |
6V | 0.001V |
±(1.0% + 5) |
60V | 0.01V | |
450V | 0.1V | ±(1.2% + 5) |
- Min/ input voltage:0.9V DC
-Input impedance:10MW
- Maximum/ input voltage:450V AC (Effective value)or 450V DC
- Frequency range:45Hz ~100Hz
3.2.5 Frequency
Range | Resolution | Accuracy |
99.99Hz | 0.01Hz |
±(0.1% + 2)
±(0.1% + 2)
|
999.9Hz | 0.1Hz | |
9.999kHz | 0.001kHz | |
99.99KHZ | 0.01kHZ | |
999.9KHZ | 0.1kHZ | |
9.999MHZ | 0.001MHZ |
- Overload protection:250V DC or AC(Effective value)
- Input range:≥ 200mV~10VPP(Effective value)With the increase of the measured frequency, the input voltage should be increased)
3.2.6 Resistance
Range | Resolution | Accuracy |
6kW | 0.001kW | ±(0.8% + 3) |
60kW | 0.01kW | |
600kW | 0.1kW | |
6MW | 0.001MW | ±(1.2% + 3) |
10MW | 0.1MW |
- Overload protection:250V DC or AC(Effective value)
3.2.7 Continuity test
Range | Resolution | Function |
0. 1W | If the measured line resistance is less than 50, enclosing the instrument may sound a buzzer |
- Overload protection:600V DC or AC(Effective value)
3.2.8 Temperature test
Range | Accuracy | Resolution |
-20℃-300℃ | ±(1.0%+4d) | 1℃ |
301℃-1000℃ | ±(1.9%+5d) | 1℃ |
-4℉-600℉ | ±(1.2%+6d) | 1℉ |
601℉-1832℉ | ±(1.9%+6d) | 1℉ |
- Overload protection: 250V DC or AC (rms)
3.2.9 Capacitance
Range | Resolution | Accuracy |
9.999nF | 0.001nF | ±(4.0% of reading +20words) |
99.99nF | 0.01nF | ±(2.0% of reading +5words) |
999.9nF | 0.1nF | |
9.999mF | 0.001mF | ±(2.0% of reading +5words) |
99.99mF | 0.01mF | |
999.9mF | 0.1mF | |
9.999mF | 0.001mF | ±(5.0% of reading +3words) |
99.99mF | 0.01mF | Not calibrated |
- Overload protection: 250V DC or AC (rms)
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
3000000-8000000
Employee Number:
80~100
Ecer Certification:
Active Member
Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ... Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ...
Get in touch with us
Leave a Message, we will call you back quickly!