Payment Terms | T/T, Western Union,Paypal,L/C |
Supply Ability | 50000pcs/month |
Delivery Time | 5-35days |
Packaging Details | 1pcs/gift box, 30~50pcs/ctn |
Mode | CHX-CM005 |
Display | LCD |
DC CURRENT range | 20A |
Resolution | 0.01A |
maximum/ input current | 100A DC |
Relative humidity | <75% |
Brand Name | CHX |
Model Number | CHX-CM005 |
Certification | CE, RoHS |
Place of Origin | CHINA |
View Detail Information
Explore similar products
600V 750V Digital Clamp Multimeter 9.999Hz 99.99Hz With LCD Display
60A 0.01A Digital Clamp Tester , 400A AC DC Clamp On Amp Meter
400A AC Digital Clamp Multimeter Voltage Tester 1999 Display 190g
Data Keep Clamp On Digital Multimeter 190g 10MW 184.0×66.0×32.5mm
Product Specification
Payment Terms | T/T, Western Union,Paypal,L/C | Supply Ability | 50000pcs/month |
Delivery Time | 5-35days | Packaging Details | 1pcs/gift box, 30~50pcs/ctn |
Mode | CHX-CM005 | Display | LCD |
DC CURRENT range | 20A | Resolution | 0.01A |
maximum/ input current | 100A DC | Relative humidity | <75% |
Brand Name | CHX | Model Number | CHX-CM005 |
Certification | CE, RoHS | Place of Origin | CHINA |
High Light | 0.01A Digital Clamp Multimeter ,20A Digital Clamp Multimeter ,20A Digital Auto Range Multimeter |
Descriptions
-This meter is a portable professional measuring instrument with LCD and back light easily reading. The ‘single-hand operation’ design for the range switch makes measurement simple and easy. Overload protection and low battery indication are provided. It is an ideal multi-function Instrument with scores of practical applications for professional, workshop, school, hobby and home use.
- - used for AC current,DC current (only 220D),True RMS AC voltage sine wave, DC voltage, frequency, duty ratio, resistance, capacitance measurement and the continuity test, diode test, temperature test(only 200D)and excitation voltage test.
- Automatic range
- Data hold
- auto power off
SAFETY INFORMATION
This instrument strictly follow GB/T 13978-92 Generic specification ,accordance with GB4793.1-1995(IEC-61010-1, IEC-61010-2-032)electronic measuring instruments safety requirements,Belong to the two class of pollution,Voltage standard is CAT IV 300Vand CAT III 600V.
Please Follow all safety and operating instructions to ensure safe use of the meter.
Follow all safety and operating instructions to ensure safe use of the meter.
Warning
BE EXTREMELY CAREFUL WHEN USING THIS METER. Improper use of this device can result in electric shock or destruction of the meter. Take all normal safety precautions and follow the safeguards suggested in this manual.
To exploit full functionality of the meter and ensure safe operation, please read carefully and follow the directions in this manual.
PRELIMINARY
Follow all safety and operating instructions to ensure safe use of the meter:
- General protection against electric shock
- Protection of the meter against misuse
When the meter is delivered, check whether it has been damaged in transit.
After being stored and delivered under harsh conditions, the meter should be checked and confirmed whether any damages have been incurred.
Test leads must be kept in good condition. Before using check whether the insulation on test leads has been damaged and any wire has been exposed.
Use the test leads supplied to ensure operation safety. If required, they must be replaced with test leads of the same model or class.
Technical specifications:
Environment temperature:235℃ Relative humidity:<75%
3.2.1 True RMS
3.2.1.1 For measuring non-sinusoidal waveforms, test error which is occurred by using True RMS measurement techniques is less than by using traditional average-reading techniques.
3.2.1.2 Both sinusoidal and non-sinusoidal waveforms can be tested by True RMS Clamp Meter exactly. At AC A & AC V ranges, even short two test probes there are still 1-50 digits might be displayed on LCD. This is normal. Test result will not be affected.
3.2.1.3 At AC A and AC V range, True RMS value can be tested only when input signal is more than 2% -100%of full range.
3.2.2 AC Current
Range | Resolution | Accuracy |
2A | 0.001A | ±(4.0% + 20) |
20A | 0.01A | ±(2.5% + 8) |
100A | 0.1A |
- maximum/ input current:100A AC
- Frequency range:50Hz
3.2.3 DC CURRENT(2008D)
Range | Resolution | Accuracy |
20A | 0.01A | ±(2.5% + 10) |
100A | 1A |
- maximum/ input current:100A DC
3.2.4 DC Voltage
Range | Resolution | Accuracy |
2V | 0.001V | ±(0.8% + 5) |
20V | 0.01V | |
200V | 0.1V | |
500V | 0.1V | ±(1.0% + 5) |
- Input impedance:10MW
- Maximum/ input voltage:600V AC (Effective value)OR 600V DC
NOTICE:
At small voltage range, unsteady readings will appear before the test leads contact the circuit. This is normal because the meter is highly sensitive. When the test leads contact the circuit, the true reading will be shown.
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
3000000-8000000
Employee Number:
80~100
Ecer Certification:
Active Member
Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ... Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ...
Get in touch with us
Leave a Message, we will call you back quickly!