Payment Terms | T/T, Western Union,Paypal,L/C |
Supply Ability | 50000pcs/month |
Delivery Time | 5-35days |
Packaging Details | 1pcs/gift box, 30~50pcs/ctn |
Model | CHX-DM004 |
Measuring Current Range | 20A |
Measuring Voltage Range | DC 1000V AC 750V |
Resistance | 60MΩ |
Capacitance | 99.9mF |
Operating Temperature | -20℃ ~ +40℃ |
Display | 6000 Counts LCD |
AC Voltage | 750V |
Brand Name | CHX |
Model Number | CHX-DM004 |
Certification | CE, RoHS |
Place of Origin | CHINA |
View Detail Information
Explore similar products
600uA Handheld Digital Multimeter AC DC 60V 600V 1000V Non Contact Voltage Test
250V LCD Digital Multimeter Tester 10MΩ Overload protection
0.1V High Accuracy Digital Multimeter 600V 40Hz 1000Hz True RMS
600kQ 6MQ 60MQ LCD Digital Multimeter 1000v Non Contact Voltage Test
Product Specification
Payment Terms | T/T, Western Union,Paypal,L/C | Supply Ability | 50000pcs/month |
Delivery Time | 5-35days | Packaging Details | 1pcs/gift box, 30~50pcs/ctn |
Model | CHX-DM004 | Measuring Current Range | 20A |
Measuring Voltage Range | DC 1000V AC 750V | Resistance | 60MΩ |
Capacitance | 99.9mF | Operating Temperature | -20℃ ~ +40℃ |
Display | 6000 Counts LCD | AC Voltage | 750V |
Brand Name | CHX | Model Number | CHX-DM004 |
Certification | CE, RoHS | Place of Origin | CHINA |
High Light | 99.9mF LCD Digital Multimeter ,750V LCD Digital Multimeter ,99.9mF Backlight Multimeter |
DC 1000V AC 750V 6000 Counts LCD Voltage Tester With Led Torch
Description:
1. Overload protection
2. Low battery display
3. Backlight function
4. Diode test
5. NVC
6. Led torch
Specification:
Place of Origin | China |
Model | CHX-DM004 |
Measuring Current Range | 20A |
Measuring Voltage Range | DC 1000V AC 750V |
Resistance | 60MΩ |
Capacitance | 99.9mF |
Operating Temperature | -20℃ ~ +40℃ |
Display | 6000 Counts LCD |
AC Voltage | 750V |
Package size | 19X9X5cm |
Gross weight | 0.700Kg |
3.2 Technical indicators
Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
3.2.1 True rms zero input
3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.
3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.
3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.
3.2.2 DC voltage
Range | Resolution | Accuracy |
6V | 0.001V | ±(0.5% of reading + 5 words) |
60V | 0.01V | |
600V | 0.1V | ±(0.8% of reading + 5 words) |
- Input impedance: 10MΩ
- Maximum input voltage: 600V DC or 600V AC (rms)
Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
3.2.3 AC voltage
Range | Resolution | Accuracy |
6V | 0.001V | ±(0.8% of reading + 3words) |
60V | 0.01V | |
600V | 0.1V | ±(1.0% of reading + 10words) |
- Input impedance: 10MΩ
- Maximum input voltage: 600V AC (RMS) or 600V DC
- Frequency range: 40 ~ 1000Hz True RMS
Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
3.2.4 Alternating current
Range | Resolution | Accuracy |
600.0uA | 0.1uA | ±(1.5% of reading +10words) |
6000uA | 1uA | |
60.00mA | 0.01mA | |
600.0mA | 0.1mA | |
6A | 0.001A | ±(2.5% of reading +10words) |
10A | 0.01A |
- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
- Frequency response: 40Hz ~ 1000Hz True RMS.
FAQ:
Q: How can i get the price?
A: We usually quote within 24 hours after we get your inquiry(Except weekend and holidays).Ifyou are very urgent to get the price,please email us or contact us in other ways so that we can offeryou a quote.
Q: Can I buy samples placing orders? A: Yes.Please feel free to contact us.
Q: What is your lead time?
A: It depends on the orderquantity and the season you place the order.Usually we can ship within7-15days for small quantity,and about 30 days for large quantity.
Q: What is your payment term?
A: T/T,Western Union,L/C,and Paypal. This is negotiable.
Q: What is the shipping method?
A: It could be shipped by sea,by air or by express(EMS,UPS,DHL,TNT,FEDEXand ect).Please confirm with us before placing orders.
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
3000000-8000000
Employee Number:
80~100
Ecer Certification:
Active Member
Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ... Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ...
Get in touch with us