Payment Terms | T/T, Western Union,Paypal,L/C |
Supply Ability | 50000pcs/month |
Delivery Time | 5-35days |
Packaging Details | 1pcs/gift box, 30~50pcs/ctn |
Display | LCD |
Battery type | 1.5V AAA |
Battery voltage indication | LCD Symbol |
Temperature coefficient | less 0.1 |
product name | Digital Clamp Multimeter |
parts | LCD Monitor |
Brand Name | CHX |
Model Number | CHX-CM010 |
Certification | CE, RoHS |
Place of Origin | CHINA |
View Detail Information
Explore similar products
High Accuracy Digital Clamp Meter Multimeter with LCD display
Pocket Size Digital Multimeter
340g Digital Clamp Meter Multimeter
Auto Range Digital Clamp Multimeter
Product Specification
Payment Terms | T/T, Western Union,Paypal,L/C | Supply Ability | 50000pcs/month |
Delivery Time | 5-35days | Packaging Details | 1pcs/gift box, 30~50pcs/ctn |
Display | LCD | Battery type | 1.5V AAA |
Battery voltage indication | LCD Symbol | Temperature coefficient | less 0.1 |
product name | Digital Clamp Multimeter | parts | LCD Monitor |
Brand Name | CHX | Model Number | CHX-CM010 |
Certification | CE, RoHS | Place of Origin | CHINA |
High Light | 1.5V AAA Digital Clamp Multimeter ,190g Digital Clamp Multimeter ,1.5V LCD Display Multimeter |
Backlight And Lighting Clamp Head Digital Clamp Multimeter With LCD Monitor
function exchange
Press Power button, then can measure automatically
Backlight and lighting clamp head
1) if the ambient light is too dark, difficulties to get resulting, press the “ H/ ”key more than 2seconds,Open the back light, automatically shut down in about 30 seconds.
Automatic power off
1) Without operation after 15 minutes ,The meter will enter the sleep state automatically shut down to save power. 1 minutes before the shutdown, each 1 minutes the buzzer 1 sound prompt, dormant into a long sound after that before the shutdown.
Buzzer
Press any key or switch the rotation function , if the function key is effective, the buzzer will be issued "Beep" sound (about 0.25 seconds);set in measuring voltage or current is greater than the alarm value,For example, AC voltage greater than 600V DC voltage is greater than 600V, AC / DC current is more than 200A, the buzzer will continue as pronunciation and to be a over range alarm; Automatically shut down about 1 minutes before the buzzer will sound a warning for the issue of 5 times, before the shutdown will send a warning buzzer sound;;Automatic shutdown function is cancelled, every 15 minutes take 5 warnings.
Part name
⑴ Current clamp head: For current measurement
⑵ The torch of head lamp
⑶ Panel
⑷ NCV and alarm
⑸ Function selection(FUN)
⑹ LCD Monitor
⑺ Common socket
(8) Resistor, voltage, frequency and Continuity input jack
(9) Min and Max value (MAX/MIN)
(10) Reading / backlight button
(11) Function change button
(12) NCV zone
Overview
Automatic measurement and manual measurement
Overload protection
The maximum voltage allowed between the measuring terminal and earth:600V DC or 600V AC
Display:LCD
Maximum:1999 display
Polar indication:Automatic indicator,‘-’,Display negative
Over range display:‘0L’ or ‘-0L’.
Sampling time: about 3 times / sec
Display unit and power display
Automatic power off:15Minutes
Open Jaw is 25mm; test Line OD less than23mm
3.2.1 AC Current
Range | Resolution | Accuracy |
2A | 0.001A | ±(4.0% + 20) |
20A | 0.01A | ±(2.5% + 8) |
200A | 0.1A | |
400A | 1.0A |
- Max input:400A AC
- Frequency:50Hz
- When ac current is measured, the meter automatically opens an internal low-pass filter to filter out high-frequency current.
3.2.2 DC voltage
Range | Resolution | Accuracy |
2V | 0.001V | ±(0.8% + 5) |
20V | 0.01V | |
200V | 0.1V | |
600V | 0.1V | ±(1.0% + 5) |
- Input impedance:10MW
- Maximum/ input voltage:600V AC (Effective value)OR 600V DC
3.2.4 AC voltage
Range | Resolution | Accuracy |
2V | 0.001V | ±(1.2% + 5) |
20V | 0.01V | |
200V | 0.1V | |
600V | 0.1V | ±(1.5% + 5) |
- Input impedance:10MW
- Maximum/ input voltage:600V AC (Effective value)or 600V DC
In the small voltage range, the meter pen is not connected to the measured circuit, the meter may have jumping reading, this is normal, because of the high sensitivity of the meter, does not affect the actual measurement results
3.2.5 Resistance
Range | Resolution | Accuracy |
200W | 0.1W | ±(0.8% + 3) |
2kW | 0.001kW | |
20kW | 0.01kW | |
200kW | 0.1kW | |
2MW | 0.001MW | ±(1.2% + 3) |
20MW | 0.1MW |
- open-circuit voltage:About 0.4V
- Overload protection:600V DC or AC(Effective value)
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
3000000-8000000
Employee Number:
80~100
Ecer Certification:
Active Member
Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ... Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ...
Get in touch with us