Payment Terms | T/T, Western Union,Paypal,L/C |
Supply Ability | 50000pcs/month |
Delivery Time | 5-35days |
Packaging Details | 1pcs/gift box, 30~50pcs/ctn; package size: 10X5X3cm; gross weight:0.500kg |
Model | CHX-DM016 |
Resistance | 600Ω/6/60/600KΩ/6MΩ /600MΩ |
Working Temperature | -10~50℃ |
Temperature | -20 to 1000°C, -4 to 1832°F |
Duty Cycle | 0.1% - 99% |
AC Voltage | 6V/60V/600V |
Brand Name | CHX |
Model Number | CHX-DM016 |
Certification | CE, RoHS |
Place of Origin | CHINA |
View Detail Information
Explore similar products
60kQ 600kQ Handheld Digital Multimeter 600V 9.999Hz 99.99Hz
Manual Range Handheld Digital Multimeter 20mF 60Hz Backlight Function
10MΩ Universal Digital Multimeter With LCD Digital Display
750V Handheld Digital Multimeter Universal Anti Shock Protection
Product Specification
Payment Terms | T/T, Western Union,Paypal,L/C | Supply Ability | 50000pcs/month |
Delivery Time | 5-35days | Packaging Details | 1pcs/gift box, 30~50pcs/ctn; package size: 10X5X3cm; gross weight:0.500kg |
Model | CHX-DM016 | Resistance | 600Ω/6/60/600KΩ/6MΩ /600MΩ |
Working Temperature | -10~50℃ | Temperature | -20 to 1000°C, -4 to 1832°F |
Duty Cycle | 0.1% - 99% | AC Voltage | 6V/60V/600V |
Brand Name | CHX | Model Number | CHX-DM016 |
Certification | CE, RoHS | Place of Origin | CHINA |
High Light | 6MΩ Backlight Multimeter ,600MΩ Backlight Multimeter ,600MΩ Portable Digital Multimeter |
600V DC Or 600V AC Temperature And Humidity Meter Professional Measuring Instruments
Description
- instrument for the portable, professional measuring instruments, with LCD digital display, and a backlight,
Users are easy to read. The range switch is easy to measure with one hand operation, with overload protection and low battery indication. Whether professional, factory, school, enthusiast or family use, are an ideal
Multi-function instrument.
- instrument for AC current, DC current, AC voltage sine wave true RMS, DC voltage, frequency, duty cycle, resistance, capacitance measurement and line off, diode testing, temperature measurement.
- The instrument has an automatic range function.
- The meter has a reading hold function.
- The instrument has an automatic shutdown function.
Technical indicators
Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
3.2.1 True rms zero input
3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.
3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.
3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.
3.2.2 DC voltage
Range | Resolution | Accuracy |
6V | 0.001V | ±(0.5% of reading + 5 words) |
60V | 0.01V | |
600V | 0.1V | ±(0.8% of reading + 5 words) |
- Input impedance: 10MΩ
- Maximum input voltage: 600V DC or 600V AC (rms)
Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
3.2.3 AC voltage
Range | Resolution | Accuracy |
6V | 0.001V | ±(0.8% of reading + 3words) |
60V | 0.01V | |
600V | 0.1V | ±(1.0% of reading + 10words) |
- Input impedance: 10MΩ
- Maximum input voltage: 600V AC (RMS) or 600V DC
- Frequency range: 40 ~ 1000Hz True RMS
Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
3.2.4 Alternating current
Range | Resolution | Accuracy |
600.0uA | 0.1uA | ±(1.5% of reading +10words) |
6000uA | 1uA | |
60.00mA | 0.01mA | |
600.0mA | 0.1mA | |
6A | 0.001A | ±(2.5% of reading +10words) |
10A | 0.01A |
- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
- Frequency response: 40Hz ~ 1000Hz True RMS.
3.2.5 DC
Range | Resolution | Accuracy |
600.0uA | 0.1uA | ±(1.0% of reading +5words) |
6000uA | 1uA | |
60.00mA | 0.01mA | |
600.0mA | 0.1mA | |
6A | 0.001A | ±(2.0% of reading +10words) |
10A | 0.01A |
- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
3.2.6 Frequency
Range | Resolution | Accuracy |
9.999Hz | 0.001Hz | ±(1.0% of reading +3words) |
99.99Hz | 0.01Hz | |
999.9Hz | 0.1Hz | |
9.999kHz | 0.001kHz | |
99.99KHZ | 0.01kHZ | |
999.9KHZ | 0.1KHZ | |
9.999MHZ | 0.001MHZ |
- Overload protection: 250V DC or AC (rms)
- Input voltage range: 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)
3.2.7 Duty cycle
Range | Resolution | Accuracy |
0.1 – 99.9% | 0.1% | ± 3.0% |
- Frequency response: 10 ~ 10MHz
- Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)
- Maximum input voltage: 250V AC (rms)
Resistance
Range | Resolution | Accuracy |
600W | 0.1W | ±(0.8% of reading +3words) |
6kW | 0.001kW | |
60kW | 0.01kW | |
600kW | 0.1kW | |
6MW | 0.001MW | ±(1.2% of reading +3words) |
60MW | 0.01MW |
- Open circuit voltage: approx. 1.0V
- Overload protection: 250V DC or AC (rms)
Transistor test
Range | Description | Test Conditions |
hFE | The display reads the approximate value of hFE(0~1000) | Base current of about 10uA; Vce about 2.8V |
Capacitance
Range | Resolution | Accuracy |
9.999nF | 0.001nF | ±(4.0% of reading +3words) |
99.99nF | 0.01nF | |
999.9nF | 0.1nF | |
9.999mF | 0.001mF | |
99.99mF | 0.01mF | |
999.9mF | 0.1mF | |
9.999mF | 0.001mF | ±(5.0% of reading +3words) |
99.99mF | 0.01mF | Not calibrated |
- Overload protection: 250V DC or AC (rms)
Temperature test
Range | Accuracy | Resolution |
-20℃-300℃ | ±(1.0%+4d) | 1℃ |
301℃-1000℃ | ±(1.9%+5d) | 1℃ |
-4℉-600℉ | ±(1.2%+6d) | 1℉ |
601℉-1832℉ | ±(1.9%+6d) | 1℉ |
- Overload protection: 250V DC or AC (rms)
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
3000000-8000000
Employee Number:
80~100
Ecer Certification:
Active Member
Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ... Shenzhen Xishen Development Co.,LTD,business mogel for testing instruments for more than 10 years.Our engineers have been in this industry for over 20 years and served some of the most famous customers from all over the world.We can provide below services for all our partners in this ...
Get in touch with us
Leave a Message, we will call you back quickly!