IEC 60664-1 Clause 6.2.2.1 Impulse Voltage Generator 20KV High-Voltage Impulse

  1. MOQ: 1
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 10 sets per month
Delivery Time 30 Days
Packaging Details Plywood Case
DC high voltage 20kV (Max) ±5%
Impulse wavefront time 1.2 µs ± 30 %
Half wave time 50 µs ± 20 %
Internal resistance 2Ω ± 10%
Peak voltage 300V-20kV
Impact cycles 1 ~ 9999
Interval time 10 ~ 99s
Rated voltage 220V, 50Hz
Brand Name Sinuo
Model Number SN1104-20KV
Certification Calibration Certificate (Cost Additional)
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 10 sets per month
Delivery Time 30 Days Packaging Details Plywood Case
DC high voltage 20kV (Max) ±5% Impulse wavefront time 1.2 µs ± 30 %
Half wave time 50 µs ± 20 % Internal resistance 2Ω ± 10%
Peak voltage 300V-20kV Impact cycles 1 ~ 9999
Interval time 10 ~ 99s Rated voltage 220V, 50Hz
Brand Name Sinuo Model Number SN1104-20KV
Certification Calibration Certificate (Cost Additional) Place of Origin China
High Light 20KV Impulse Voltage GeneratorHigh-Voltage Impulse Voltage GeneratorIEC 60664-1 Impulse Voltage Generator

 

IEC 60664-1 Clause 6.2.2.1 Impulse Voltage Generator 20KV High-Voltage Impulse

 

Product Information:
 

The Impulse Test Generator conforms to the standard requirements of IEC 60664-1 clause 6.2.2.1, etc.

It is used to verify that the appliances shall withstand the transient over-voltages to which they may be subjected. The impulse voltage test is a destructive test in which a breakdown occurs if the test specimen cannot withstand the applied voltage. When the sample breaks down, sparks and discharge sounds will be generated. The peak voltage of the instrument will drop significantly (close to zero) when it is no-load. When the same voltage is applied again, the above phenomenon will occur.

 

Feature:

 

An impulse voltage generator, also known as a lightning impulse generator or high-voltage impulse generator, is a specialized electrical testing device used to generate high-voltage impulses that simulate lightning strikes or other transient voltage phenomena. It is commonly used in electrical power systems, insulation testing, and research laboratories to assess the performance and withstand capability of electrical equipment and insulation materials under high-voltage impulses.

Key components and features of a typical impulse voltage generator include:

Charging System: The generator includes a high-voltage charging system that accumulates electrical energy from an external power source. This system typically consists of transformers, capacitors, and a charging circuit to store the required energy for generating the impulse voltage.
Impulse Voltage Generation Circuit: The generator employs a specialized circuit that rapidly discharges the stored energy to produce high-voltage impulses. This circuit may include switches, spark gaps, and resistors to control the discharge process and shape the impulse waveform.
Voltage Divider: A voltage divider is integrated into the generator to measure the generated impulse voltage accurately. The voltage divider consists of resistors and capacitors connected in a specific configuration to attenuate the high voltage and provide a representative voltage measurement for analysis.
Impulse Voltage Output Terminals: The generator is equipped with output terminals where the high-voltage impulses are applied to the test object or insulation material under evaluation. These terminals are designed to handle the high voltages and provide a safe and controlled connection to the test setup.
Control and Monitoring System: The generator features a control panel or system that allows operators to set and adjust the impulse parameters, such as voltage level, rise time, and duration. It may also include monitoring instruments to display and record the generated impulse waveform and provide real-time measurements.
Safety Features: Impulse voltage generators incorporate various safety features to protect both the operator and the equipment being tested. These features may include grounding systems, interlocks, and insulation barriers to prevent electrical accidents and ensure safe operation.
Impulse voltage generators are used to simulate high-voltage transients, such as lightning strikes, switching surges, or voltage spikes, which can occur in electrical systems. They are employed to test and evaluate the insulation strength, withstand capability, and reliability of electrical components, cables, transformers, surge arrestors, insulators, and other equipment.

When operating an impulse voltage generator, it is crucial to follow safety protocols and guidelines provided by the manufacturer. Proper grounding, personal protective equipment, and adherence to testing standards, such as IEC or IEEE, are essential to ensure accurate and safe testing procedures.

 
Technical Parameters:

 

Model SN1104-20KV
DC high voltage 20kV (Max) ±5%
Impulse voltage wave

Impulse wavefront time: 1.2 µs ± 30 %;

Half value of after wave time: 50 µs ± 20 %

Please note that the waveform should be checked on an external oscilloscope

Instrument internal resistance 2Ω ± 10%, 12Ω ± 10% and 500Ω± 10%

Peak voltage

300V-20kV, Low: 300 V~ 2,500V; High: 2,500 V~ 20kV
Impact interval time 10~ 99s can be preset
Impact cycles 1 ~ 9999
Polarity Positive and negative
Working power source Rated voltage: ~ 220V±10%, 50/60Hz
Use environment Temperature: 15°C-35°C, relative humidity 10%-75%
Dimension 600mm×570mm×1500mm
Weight 90 KG
 
Details
 
 
 
 
 
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Total Annual:

    800000-1500000

  • Employee Number:

    30~50

  • Ecer Certification:

    Verified Supplier

Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la... Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la...

+ Read More

Get in touch with us

  • Reach Us
  • Sinuo Testing Equipment Co. , Limited
  • Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
  • https://www.sinuotek.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement