China Switches Intended for Self-ballasted Lamp Loads Automatic Breaking Capacity Test
China Switches Intended for Self-ballasted Lamp Loads Automatic Breaking Capacity Test

  1. China Switches Intended for Self-ballasted Lamp Loads Automatic Breaking Capacity Test
  2. China Switches Intended for Self-ballasted Lamp Loads Automatic Breaking Capacity Test
  3. China Switches Intended for Self-ballasted Lamp Loads Automatic Breaking Capacity Test
  4. China Switches Intended for Self-ballasted Lamp Loads Automatic Breaking Capacity Test

Switches Intended for Self-ballasted Lamp Loads Automatic Breaking Capacity Test

  1. MOQ: 1
  2. Price: Customized
  3. Get Latest Price
Payment Terms L/C, , T/T, Western Union, MoneyGram
Supply Ability 20 sets per month
Delivery Time 30 Days
Packaging Details Plywood
Test Station 3 stations
Test Stroke 0.1~100mm
Test Speed 0.1~200mm/s
Voltage Display Range 0 ~ 300V
Power Display Range 0~9KW
Control System IPC
Brand Name Sinuo
Model Number SN2117F
Certification Calibration Certificate (Cost Additional)
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, , T/T, Western Union, MoneyGram Supply Ability 20 sets per month
Delivery Time 30 Days Packaging Details Plywood
Test Station 3 stations Test Stroke 0.1~100mm
Test Speed 0.1~200mm/s Voltage Display Range 0 ~ 300V
Power Display Range 0~9KW Control System IPC
Brand Name Sinuo Model Number SN2117F
Certification Calibration Certificate (Cost Additional) Place of Origin China
High Light switch endurance testerplug socket tester

 

Automatic Breaking Capacity Test System for Switches Intended for Self-ballasted Lamp Loads

 

Standards & Clauses:

 

This system is designed and manufactured according to the standard of IEC 60669-1:2017 clause 19.3 and IEC 60669-2-1:2015 clause 19.109. It is a fully automatic test system based on the test readability of a switch with a rated voltage of 250V, including an intelligent industrial control system (built-in oscilloscope), a switch endurance test machine, and a self-ballasted lamp load cabinet. (The switch with rated voltage of 130V needs to be separately configured with self-ballasted lamp load box).

 

Samples and Restrictions:

 

Switches intended for self ballasted lamp loads

 

Application:

 

This device is suitable for breaking capacity and normal operation life test of switches intended for self ballasted lamp loads. Switches intended for self ballasted lamp (SBL) loads shall withstand, without excessive wear or other harmful effect, the electrical and thermal stresses occurring when controlling self ballasted lamp circuits. To verify whether the switch has sustained arcing nor welding of the contacts occur, any contacts adhesion phenomenon or long term closure or disconnection phenomenon, to test whether excessive wear or other harmful consequences.

 

Test Principle:

 

IEC60669-1:2017 and IEC60669-2-1:2015, only for switches with a rated voltage of 250V.

The load box circuit shall be in accordance with Figure 12b and clause19.3, with rectifier bridge and capacitor.

 

The value of R2 and C in load B shall be chosen in order reach the values (±5%) for I peak and I2t as given in the Table 19 when the switching contact closes at 90°±5° phase-angle. The value of R4 shall be chosen to reach current in amperes to reach the corresponding SBL power as given in Table 19.


The value of R2 and C in load B shall be chosen’ mean that the resistance R3 and the capacitor C is adjustable;
Values (±5%) for I peak and I2t as given in the Table 19 when the switching contact closes at 90°±5° phase-angle’ mean that the integral of the calibration I peak and I2t is obtained at the 90 ° closing, and the equipment must have a 90 ° closing control. The 90 ° closing control does not work during normal testing, and the on/off of the switch is turned on at a random phase angle as in daily operation;
‘The value of R4 shall be chosen to reach current in amperes to reach the corresponding SBL power’ mean that this rated current is not the rated current of the switch, but the corresponding power of Table 2.

 

Technical Parameters:

 

 

Item Content
Power Match client's local power supply
Intelligent industrial control system

IPC: IPC-810E

Configuration software: E5

Oscilloscope: Tektronix or Agilent

Acquisition module: multiple

Dimensions: WDH=600*500*1450mm,

surface electrostatic powder spraying

Switch Endurance Test Machie

Station: 3 independent test stations

Control system: 7-inch color LCD touch screen +PLC+ servo motor, It has a communication interface, which is convenient for online use or communication with other devices (such as various loads), enabling data collection and statistics.

Test stroke: 0.1~100mm, can be preset

Test speed: 0.1~200mm/s, can be set

On/Off time: the ‘on’ period shall be(25+5 0)% of the total cycle and the ‘off’ period (750 -5)%, 0.1~99.9 can be preset

Operating rate: 3 - 40 times can be set, associated with test stroke, test speed and on/off time setting

Alarm detection: Built-in detection circuit, when the product is detected to be unqualified, there is an audible and visual alarm, and there are text prompts:

  • When the switch is bonded, continuous conduction occurs;
  • When the electric shock burns out, it cannot be connected;
  • When the count arrives.

Load connection port: different test loads can be connected as needed, such as tungsten filament lamp load, externally ballasted lamp load, TV load, inductive load, capacitive load, motor load and so on.

Dimension:W1250mm×D650mm×H1150mm;

Weight:100kg.

Self-ballasted Lamp Load Cabinet

Voltage display value:Range 0 ~ 300V, precision 0.5,

Power display value:0~9KW, precision 0.5

Output channel: 3 channels (two channels are 250W and the other channel is 400W)

Switch rated voltage: 250V ~, the input voltage is adjustable,All operating parameters are set at 250V~, including W, Ipeak, I2t, and inrush current waveforms.

Rated current 10A, 13A, 16A, 20A four optional

Each device provides a closing control device (touch screen select "calibration" function),each time is in the 90 degree angle conduction, this function can be used for initial equipment calibration and measurement verification.

With long on/ long off protection function, the protection time of 1 ~ 99S can be preset, shutdown alarm protection.

Use environment Temperature 5 ~ 40 °C, relative humidity 20 ~ 90% RH, atmospheric pressure 80 ~ 106kpa. No severe vibration, no electromagnetic interference, no dust, corrosive gas, good heat dissipation.
 
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Total Annual:

    800000-1500000

  • Employee Number:

    30~50

  • Ecer Certification:

    Verified Supplier

Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la... Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la...

+ Read More

Get in touch with us

  • Reach Us
  • Sinuo Testing Equipment Co. , Limited
  • Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
  • https://www.sinuotek.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement