China factories

China factory - Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co. , Limited

  • China,Guangzhou ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China High Performance Shielding Effectiveness EMC Test Equipment EN 50147 Electromagn
China High Performance Shielding Effectiveness EMC Test Equipment EN 50147 Electromagn

  1. China High Performance Shielding Effectiveness EMC Test Equipment EN 50147 Electromagn

High Performance Shielding Effectiveness EMC Test Equipment EN 50147 Electromagn

  1. MOQ: 1
  2. Price: Customized
  3. Get Latest Price
Payment Terms L/C, , T/T, Western Union, MoneyGram
Supply Ability 1 set per month
Delivery Time 60 Days
Packaging Details Plywood
Test Samples Electronic and electrical equipment
Room Size Customized
Power Supply 380V ± 10% 50 / 60Hz
Applied Standards EN 50147, CISPR17, etc.
Brand Name Sinuo
Model Number SN662
Certification Calibration Certificate (Cost Additional)
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, , T/T, Western Union, MoneyGram Supply Ability 1 set per month
Delivery Time 60 Days Packaging Details Plywood
Test Samples Electronic and electrical equipment Room Size Customized
Power Supply 380V ± 10% 50 / 60Hz Applied Standards EN 50147, CISPR17, etc.
Brand Name Sinuo Model Number SN662
Certification Calibration Certificate (Cost Additional) Place of Origin China
High Light emc test systemsemc testing laboratory

EN 50147 Electromagnetic Shielded Room High-performance Shielding Effectiveness EMC Test Equipment​

 

Standards & Clauses:

 

EN50147 “High-performance shielding room shielding effectiveness of the measurement method”
CISPR17 “passive radio interference filter and suppression element suppression characteristics of the measurement method”
CISPR25 “Radio disturbance characteristics of vehicles, boats and internal combustion engines Limits and methods of measurement for the protection of vehicular receivers”
ISO11452-4 “Road vehicles with narrowband emitted electromagnetic energy electronic interference components test method BCI large current injection method”
GB/T 50719-2011 “Electromagnetic shielding room engineering specifications”
GB/T 12190 “Electromagnetic shielding room shielding effectiveness of the measurement method”

 

Samples and Restrictions:

 

The electromagnetic shielding room is used to isolate the electromagnetic environment indoors and outdoors to ensure the normal operation of indoor electronic and electrical equipment. Mainly used for conducted emission test, conducted immunity test, EMI discontinuous interference test, etc.

 

Application:

 

Electrical appliances and electronic devices, including in-car electronic systems, generate a certain amount of electromagnetic waves at work that may interfere with surrounding equipment or be received by specialized equipment.
The electromagnetic shielding room is used to isolate the electromagnetic environment indoors and outdoors, which can prevent external electromagnetic interference from entering the room to affect the test, and can limit the electromagnetic leakage of indoor high-power high-frequency equipment to prevent the influence to people and equipment around. It is the ideal venue for EMC testing.

 

Test Principle:

 

Electromagnetic shielding room is mainly used for automotive electronic conduction emission (CE) test, transient conducted immunity test, bulk current injection method (BCI) test, stripline method test, etc.

 

Structure:

 

Power supply: 380V ± 10% 50 / 60Hz
Ambient temperature: 5 °C ~ +40 °C, there should be no high concentration of dust, corrosive gas, flammable and explosive objects

 

Typical Application​:

 

Typical Application Conducted Emission Test (CE)
Discontinuous Interference Test (CLICK)
Conducted Immunity Test (CS)
RF Disturbance Power Test (RFP)
Tricyclic Antenna Radiation Test (MFI)
Inductive Current Density Test(EMF)
Harmonic currents, voltage fluctuations and flicker (Harmonic & Flicker)
 
Shielding effectiveness SE (According to EN50147-1):
 
Field Source Frequency (MHz) Shielding Effectiveness (dB)
Magnetic Field 0.014 ≧70
Magnetic Field / Electric Field 0.1 ≧90
Magnetic Field / Electric Field 1 ≧100
Electric Field 100 ≧110
Electric Field 450 ≧110
Electric Field 950 ≧100
Electric Field 3000 ≧100
Electric Field 18000 ≧100
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Total Annual:

    800000-1500000

  • Employee Number:

    30~50

  • Ecer Certification:

    Verified Supplier

Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la... Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la...

+ Read More

Get in touch with us

  • Reach Us
  • Sinuo Testing Equipment Co. , Limited
  • Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
  • https://www.sinuotek.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement