Payment Terms | L/C, , T/T, Western Union, MoneyGram |
Supply Ability | 20 sets per month |
Delivery Time | 30 Days |
Packaging Details | Plywood |
Standards | IEC UL VDE BS and etc. |
Application | Electrical safety test |
Test Contents | Multiple |
Structure | Floor-standing |
Brand Name | Sinuo |
Model Number | SN2212S/F/B |
Certification | Calibration Certificate (Cost Additional) |
Place of Origin | China |
View Detail Information
Explore similar products
75g Test Punch With 60° Conical Tungsten Carbide Tip IEC60335-2-24 Clause 22.116
IEC 60335-2-23 Skin or Hair Care Appliance Swivel Connection 50 r/min Rotation
IEC 60335-1 Oxygen Bomb Aging Test Chamber 4000cm3 Stainless Steel Air Bomb Tank
SS Electrical Appliance Tester IEC 60335-1 Clause 20.2 Similar To Test Probe B
Product Specification
Payment Terms | L/C, , T/T, Western Union, MoneyGram | Supply Ability | 20 sets per month |
Delivery Time | 30 Days | Packaging Details | Plywood |
Standards | IEC UL VDE BS and etc. | Application | Electrical safety test |
Test Contents | Multiple | Structure | Floor-standing |
Brand Name | Sinuo | Model Number | SN2212S/F/B |
Certification | Calibration Certificate (Cost Additional) | Place of Origin | China |
High Light | electrical installation test equipment ,ac hipot test equipment |
Electrical Safety Comprehensive AC Hipot Test Equipment , Hipot Insulation Tester
Standards & Clauses:
IEC60884-1:2013 “Plugs and socket-outlets for household and similar purposes- Part1: General requirements”
IEC60335-1:2016 “Household and similar electrical appliances-Safety-Part1: General requirements”
IEC60950-1:2013 “Information technology equipment-Safety-Part1: General requirements”
IEC60065:2014 “Audio, video and similar electronic apparatus-Safety requirements”
Samples and Restrictions:
Household appliances, electrical accessories, lamps, etc.
Application:
Various types of home appliance manufacturers, as well as institutions that conduct home appliance safety testing and certification, research institutes
Test Contents:
AC Hipot test, insulation resistance test, ground resistance test, leakage current test, run power and low voltage start performance test
Structure:
Floor-standing
Technical Parameters:
AC Hipot test | |||
Booster rated output capacity | 500VA (5000V/100mA), short circuit current is greater than 200mA | ||
Output voltage waveform, distortion, adjustment rate | Sine wave, <3% (pure resistance,5000V/1mA), <3% (from empty load to full load) | ||
Output voltage setting | Range | 500~5000V | |
Resolution, accuracy | 5V,±(3%×setting+10V) | ||
Frequency setting | Range, accuracy | 50Hz/60Hz, ±0.1%×setting | |
Alarming limits setting | Current upper-limit | 0.10~99.99mA | |
Current lower-limit | 0.00~10.00mA | ||
Compensation current setting | Range | 0.00~10.00mA, automatic testing, compensation can be set to ON/OFF | |
Time setting | Range | 1~999s | |
Ramp up time range | 1~100s | ||
Accuracy | ±(0.1%×setting+1count) | ||
Breakdown current alarm | Range, accuracy | 0.10~99.99mA, ±(3%×reading+3counts) | |
Insulation Resistance test | |||
Rated output capacity | 2VA(1000V/2mA) | ||
Output voltage regulation, output voltage ripple | <3%(From no load to full load), <1% | ||
Output voltage setting | Range, accuracy | DC 500V or 1000V, ±(3%×setting+3counts) | |
Alarming limits setting | Resistance upper-limit range | 0.0~99.9 MΩ,100~2000MΩ(If upper-limit is set to 0, it will not make adjudgment for upper limit) | |
Resistance lower-limit range | 0.3~99.9 MΩ, 100~2000MΩ | ||
Time setting | Range, accuracy | 1~999s, ±(0.1%×setting+1count) | |
Insulation resistance measurement | Range | 0.0~99.9 MΩ, 100~2000 MΩ | |
Accuracy | ≤200MΩ: ±(3%×reading+3counts) >200MΩ:±(8%×reading+8counts) | ||
Ground Bond Resistance test | |||
No load output voltage | <12V | ||
Output current setting | Range, accuracy | 3~30A, ±(3%×setting+0.2A) | |
Current frequency setting | Range, accuracy | Sine waveform 50Hz/60Hz, ±0.1%×setting | |
Test time setting | Range | 1~999s | |
Accuracy | ±(0.1%×setting+1count) | ||
Result display mode | Ground resistance or voltage | ||
Ground resistance display mode | |||
Alarming limits setting | Resistance upper-limit range | 3A ≤ output current ≤ 10A:10~600 mΩ 11A ≤ output current ≤ 25A:10~300 mΩ 26A ≤ output current ≤ 30A:10~200 mΩ | |
Resistance lower-limit range | 0~100 mΩ | ||
Compensation resistance setting | Range | 0~200 mΩ, automatic testing, compensation can be set to ON/OFF | |
Ground bond resistance measurement | Range, accuracy | 10~600 mΩ, ±(3%×reading+ 5counts) | |
Ground voltage display mode | |||
Alarming limits setting | Voltage upper-limit range | 30~7500 mV | |
Voltage lower-limit range | 0~3000 mV | ||
Compensation voltage setting | Range | 0~1000 mV, automatic testing, compensation can be set to ON/OFF | |
Ground bond resistance measurement | Range, accuracy | 10~7500 mV, ±(3%×reading+ 50mV) | |
Leakage Current test | |||
Leakage current test type setting | Single phase load, static/dynamic leakage current | ||
MD network selection | Standard IEC 60990 figure 4 network; other test network optional | ||
Alarming limits Setting | Current upper-limit range | 0.050~9.999mA | |
Current lower-limit range | 0.000~5.000mA | ||
Leakage current compensation setting | Range | 0.000~1.000mA, automatic testing, compensation can be set to ON/OFF | |
Time test setting | Range, accuracy | 1~999s, ±(0.1%×setting+1count) | |
Leakage current measurement | Range | 0.050~9.999mA | |
Accuracy | DC~10kHz: ± (3%×reading+0.010mA) 10 kHz ~1MHz: ± (5%×reading+0.050mA) | ||
Output voltage measurement | Range, accuracy | 60~280V(phase voltage), ±(0.5%×reading+2counts) | |
Run Power Only forAN9651S(F)/AN9651F(F)/AN9651B(F) | |||
Alarming limits setting | Power upper-limit range | 6~6000W | |
Power lower-limit range | 0~6000W | ||
Test time setting | Range, accuracy | 1~999s, ±(0.1%×setting+1count) | |
Voltage measurement | Range, accuracy | 60~280V (phase voltage), ±(0.5%×reading+2counts) | |
Current measurement | Range, accuracy | 0.030~3.999A, 4.00~25.00A, ±(0.5%×reading+2counts) | |
Active power measurement | Range, accuracy | 30.0~199.9W: ±(0.5%×reading+5W), 200~6000W(or2000W): ±(0.5%×reading+30W) | |
Power factor measurement | Range, accuracy | 0.10~1.00, ±(2%×reading+2 counts) | |
Low voltage start test | |||
Alarming limits setting | Current upper-limit range | 0.30~25.00A | |
Current lower-limit range | 0.00~25.00A | ||
Test time setting | Range, accuracy | 1~999s, ±(0.1%×setting +0.05s) | |
Voltage measurement | Range, accuracy | 60~280V (phase voltage), ±(0.5%×reading+2counts) | |
Current measurement | Range, accuracy | 0.030~3.999A, 4.00~25.00A, ±(0.5%×reading+2counts) | |
Power supply for UUT | |||
SN2212B Built-in isolation transformer | |||
Isolation transformer input voltage, frequency | Determined based on input voltage and frequency | ||
Isolation transformer output voltage ratio | Leakage current test | The output voltage is 1.06 times the input voltage | |
Run power test | The output voltage is 1.00 times the input voltage | ||
Low voltage start test | The output voltage is 0.85 times the input voltage | ||
Isolation transformer capacity | Single phase load rated capacity 6000VA | ||
Isolation transformer voltage regulation | 3% (from no load to full load) | ||
Overcurrent protection | Maximum current is 30A, automatically cut off the isolated power supply after 5s overcurrent | ||
SN2212S, SN2212F Built-in variable frequency power supply | |||
Max. output capacity | 5000VA | ||
Output voltage distortion | 1% @ 47~63Hz | ||
Output voltage stability | 1% | ||
Programmed output voltage | Voltage range | 0~300V | |
Voltage accuracy | 0.5%RD+0.5%F.S. | ||
Programmed output frequency | Frequency Range | 47~63Hz | |
Frequency stability | 0.1% | ||
Output maximum current | 0~150V file | 27A | |
0~300V file | 14A | ||
SN2212S Configured IN-Pad | |||
Processor | ARM926 core, 400MHz frequency | ||
Operating system | Windows CE | ||
Software | ESRS-Pad special software for safety test | ||
Display | 10.4” TFT color LCD | ||
Operation method | Input through touch screen, support input through USB interface mouse and keyboard | ||
Storage | 50MB FLASH, user can choose large capacity SD memory card | ||
External Interface | 2-way RS232 interface, 2-way USB interface, CAN interface, DC12V power interface | ||
Mounting brackets | 3D, full angle, display stand | ||
Bar code scanner | One barcode scanner with an RS232 interface defaulted | ||
Interface function | |||
Remote control interface | Standard, standard foot switch (start) | ||
Alarm light interface | Standard, standard three-color warning light (test, qualified, warning) | ||
Communication Interface | Standard RSA32, optional RS485, network port, GPIB, etc. | ||
Variable frequency power control interface | Optional | ||
Switch interface | Optional, start, stop, test, pass, alarm switch output | ||
Printer interface | Optional, support for dot matrix printers and micro printers | ||
General specification | |||
Verification and calibration environment | 23 ° C ± 5 ° C, (45 ~ 75)% RH, less dust | ||
Use environment | 0 ° C ± 40 ° C, (5 ~ 90)% RH, less dust | ||
Storage environment | -10 ° C ~ 55 ° C, (5 ~ 95)% RH, less dust | ||
System power | 220V±10%, 50Hz±5%, 10A | ||
System power consumption | Maximum 1000VA (excluding the operating power consumption of the tested product) | ||
System weight (without packaging) | About 80kg | ||
Dimensions (mm, without packaging) | SN2212S | 483(W)x 600(D)x 1355(H) | |
SN2212F | 483(W)x 600(D)x 1355(H) | ||
SN2212B | 530(W)x 460(D)x 1105(H) |
Company Details
Business Type:
Manufacturer
Total Annual:
800000-1500000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la... Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la...
Get in touch with us
Leave a Message, we will call you back quickly!