China factories

China factory - Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co. , Limited

  • China,Guangzhou ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China IEC 61000-4-2 20KV Intelligent Electrostatic Discharge Immunity ESD Generator
China IEC 61000-4-2 20KV Intelligent Electrostatic Discharge Immunity ESD Generator

  1. China IEC 61000-4-2 20KV Intelligent Electrostatic Discharge Immunity ESD Generator
  2. China IEC 61000-4-2 20KV Intelligent Electrostatic Discharge Immunity ESD Generator

IEC 61000-4-2 20KV Intelligent Electrostatic Discharge Immunity ESD Generator

  1. MOQ: 1
  2. Price: Customized
  3. Get Latest Price
Payment Terms L/C, , T/T, Western Union, MoneyGram
Supply Ability 10 set per month
Delivery Time 30 Days
Packaging Details Plywood
Output Voltage 0.1~20KV±5%
Discharge Interval 0.05-30s
Number of Discharges 1-9999
Output Polarity Positive/negative
Discharge Mode Contact discharge/air discharge
Discharge Method Manual / Auto
Brand Name Sinuo
Model Number SN6612
Certification Calibration Certificate (Cost Additional)
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, , T/T, Western Union, MoneyGram Supply Ability 10 set per month
Delivery Time 30 Days Packaging Details Plywood
Output Voltage 0.1~20KV±5% Discharge Interval 0.05-30s
Number of Discharges 1-9999 Output Polarity Positive/negative
Discharge Mode Contact discharge/air discharge Discharge Method Manual / Auto
Brand Name Sinuo Model Number SN6612
Certification Calibration Certificate (Cost Additional) Place of Origin China
High Light emc test systemselectromagnetic testing services

IEC 61000-4-2 20KV Intelligent Electrostatic Discharge Immunity Generator (ESD)

 

Standards & Clauses:

 

IEC 61000-4-2/GB T17626.2: electrostatic discharge immunity test
ANSI/ESD STM5.2: For electrostatic discharge susceptibility test: machine model-component level
EIA/JESD22-A114-B: electrostatic discharge sensitivity test: Human Body Model (HBM)
EIA/JESD22-A115-A: electrostatic discharge sensitivity test: machine model (MM)
ISO10605: Road vehicles-test methods for electrical disturbances from electrostatic discharge
ANSI/ESD STM5.1: For electrostatic discharge susceptibility test: Human Body Model (HBM)Component

 

Samples and Restrictions:

 

Various types of luminaires appliances, electronic circuits and equipment

 

Application:

 

Electrostatic Discharge Immunity Test mainly checks the discharge (direct discharge) caused when a person or an object touches the device and the impact on the device when a person or an object discharges (indirectly discharges) to nearby objects of the device.

 

Test Principle:

 

The intelligent electrostatic discharge generator is a high-reliability, which is specially designed according to the characteristics and requirements of the electrostatic discharge immunity test. IEC mode test, HBM mode test and MM mode test can be easily carried out by changing the discharge modules.

 

Structure:

 

Electrostatic discharge can produce 1-50A discharge current in 0.5-20ns time. Although the current is large but due to the short duration, so less energy. Electrostatic discharge generally does not harm people but may have devastating effects on electronic products such as integrated circuit chips.

 

Use Environment​:

 

Power supply: 220V±10%, 50/60Hz

Ambient temperature: 5 °C ~ +40 °C, there should be no high concentration of dust, corrosive gas, flammable and explosive objects.

 

Technical Parameters:

 

Control & Operation Electrical control and touch screen intelligent operating system
ESD Electrostatic Discharge Model
Output Voltage 0.1~20KV±5%, optional 0.1~30KV±5%
Discharge Interval 0.05-30s
Number of Discharges 1-9999
Output Polarity Positive/negative
Discharge Mode Contact discharge/air discharge
Discharge Method Manual / Auto
Discharge Network Capacitor 150Pf / resistance 330Ω (IEC), replaceable
Discharge Current Rise Time 0.6~1ns
Test Mode Single, count, 20pps, air gap discharge, contact discharge, IEC level
Standard Configuration Discharge gun, high voltage generator, built-in RC module, discharge electrode, data
Optional

Custom RC RC modules (eg 100pF/1500Ω (EDS), 150pF/150Ω (EDS), 500pF/500Ω (EDS), 500pF/5000Ω (EDS), 200pF/0Ω (EDS));

Electrostatic discharge test stand (test table 1600x800x800mm, all solid wood, meeting IEC 61000-4-2 requirements; Reference grounding plate 2700x1800mm, horizontal coupling plate 1600x800mm, vertical coupling plate 500x500mm; Grounding high voltage resistor 2x470 kΩ)

ESD calibration unit (for waveform calibration of IEC/EN61000-4-2, including 2-ohm target / 4 GHz, coaxial cable);

Attenuator

Test Configuration Layout
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Total Annual:

    800000-1500000

  • Employee Number:

    30~50

  • Ecer Certification:

    Verified Supplier

Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la... Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la...

+ Read More

Get in touch with us

  • Reach Us
  • Sinuo Testing Equipment Co. , Limited
  • Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
  • https://www.sinuotek.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement