Payment Terms | T/T |
Supply Ability | 15 Sets Per Month |
Delivery Time | 30 Days |
Packaging Details | Plywood Case |
Capacity | 5KVA |
Accuracy | 1.5% |
Output frequency | 50/60Hz |
Output waveform | Sine wave |
Test range | 1~300s |
Test step | 1s/step |
Output voltage setting range | AC 200~5000V |
Output voltage accuracy | ±(1.5%×setting+5words) |
Brand Name | Sinuo |
Model Number | SN2212 |
Certification | Calibration Certificate (Cost Additional) |
Place of Origin | China |
View Detail Information
Explore similar products
100mm Drop Tester EN 71-1 Toys 1KG Impact Strength Test Apparatus
IEC60884-1 Switch Life Tester For Insulation Parts Thermal Resistance 20N Ball
Switches Intended for Self-ballasted Lamp Loads Automatic Breaking Capacity Test
Resistive Inductive Capacitive Load Cabinet for Switches Plugs and Sockets
Product Specification
Payment Terms | T/T | Supply Ability | 15 Sets Per Month |
Delivery Time | 30 Days | Packaging Details | Plywood Case |
Capacity | 5KVA | Accuracy | 1.5% |
Output frequency | 50/60Hz | Output waveform | Sine wave |
Test range | 1~300s | Test step | 1s/step |
Output voltage setting range | AC 200~5000V | Output voltage accuracy | ±(1.5%×setting+5words) |
Brand Name | Sinuo | Model Number | SN2212 |
Certification | Calibration Certificate (Cost Additional) | Place of Origin | China |
High Light | 5KVA Multimeter Electrical Safety Tester ,IEC 60335-1 Electrical Safety Tester |
IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions
Product Information For Multimeter Electrical Safety Tester:
This multitester electrical safety tester Conforms to IEC 60598-1 clause 8.2.3, clause10.2.1, clause 10.2.2, IEC 60950:2013 clause 2.6.3.4, 5.2 and 6.2.2.3, IEC 60335-1 Clause 13, Clause 16, Clause 27 and etc. It integrates 6 functions of hi-pot, insulation, grounding, leakage, power, low-voltage start testing.
Features For Multimeter Electrical Safety Tester:
■Meet CCC, IEC, EN, VDE, BS, GS, UL and other electrical safety standards
■Unlimited storage of test conditions and test results
■Data can be copied via USB
■Fast speed: ARM high-speed processor is used as the control core of the test instrument, and data processing is comprehensive and fast
■High accuracy: safety test accuracy up to 1.5%
■Ramp rise and down of voltage withstand can be set, and with upper and lower limit alarm function
■Digital closed-loop feedback control mode, fully automatic voltage regulation mode, output voltage / current is automatically corrected, and it is not affected by external power grid fluctuations to ensure the accuracy of the test
■Two judgment modes can be chosen for ground resistance test: voltage and resistance, to meet the requirements of different national / industry standards
■Built-in one human body network fora leakage current test, which can be customized to any human body network-optional function
Technical Parameters For Multimeter Electrical Safety Tester:
Model | Functions | Capacity | Accuracy | |
SN2212 | ACW/IR/GB/LC/PWR/STR | Built-in Frequency Power Supply, 5KVA | 1.5% | |
AC withstand voltage | ||||
Output voltage setting range | AC 200~5000V | |||
Output voltage accuracy | ±(1.5%×setting+5words) | |||
Output voltage setting step | 1V | |||
Output frequency | 50/60Hz | |||
Output waveform | Sine wave | |||
Distortion of output waveform | Less than 2% (at purely resistive load) | |||
Output waveform adjustment rate | Less than(2%* setting +5V) | |||
Output capacity | 500VA | |||
Output voltage ramp-down time setting range | 0~300s | |||
Set step | 0.1s | |||
Breakdown current measurement range | 0.10~99.99mA | |||
Breakdown current test accuracy | ±(1.5%×reading+5words) | |||
Breakdown current preset upper limit | 0.10~99.99mA | |||
Breakdown current preset lower limit | 0.00~5.00mA | |||
Breakdown current preset step | 0.01mA/step | |||
Test time setting range | 1~300s | |||
Test time setting step | 1s/step | |||
Arc detection | 1~9 Level (level 9 is the highest sensitivity) | |||
Insulation resistance | ||||
Output voltage setting range | DC 200~1000V | |||
Output voltage accuracy | ± (1.5%×reading+5 words) | |||
Output voltage setting step | 1V | |||
Output capacity | 60VA | |||
Output voltage ramp-down time setting range
| 0~300s | |||
Set step | 0.1s | |||
Insulation resistance measurement range / accuracy | 1~2000 MΩ ≤100 MΩ:±(5%×displaying+3words) >100 MΩ:±(8%×displaying+8words) | |||
Insulation resistance alarm setting range | Upper limit: 0 ~ 2000MΩ; lower limit: 1 ~ 2000MΩ | |||
Test time range, resolution | 1~300s 1s/step | |||
Ground resistance | ||||
Ground current output range / accuracy | AC 5.0~30.0A | |||
Ground current accuracy | ±(1.5%×setting+0.2A) | |||
Ground resistance measurement range | 10.0~600mΩ | |||
Ground resistance measurement accuracy | ±(1.5%×displaying+3mΩ) | |||
Ground resistance alarm setting range | Upper limit: 5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ; lower limit:0.0~100mΩ | |||
Ground resistance setting step | 1mΩ | |||
Test time range | 1~300s | |||
Test time step | 1s/step | |||
Leakage current | ||||
The output voltage | 1.06 times rated voltage provided by the built-in variable frequency power supply | |||
Leak type setting | Dynamic leakage, static leakage, built-in one leakage current human body network, any human body network can be customized | |||
Output voltage measurement range | AC 50~280V | |||
Output voltage frequency | AC 45~65Hz | |||
Output voltage accuracy | ±(0.5%×displaying+2words) | |||
Leakage current measurement range | 0.05~20.00mA | |||
Leakage current measurement accuracy | ± (1.5%× displaying +10uA) | |||
Leakage current setting alarm range | Upper limit: 0.05 ~ 20.00mA; lower limit: 0.01 ~ 5.00mA | |||
Leakage current setting step | 0.01mA | |||
Test time range | 1~300s 1s/step | |||
Power | ||||
Output voltage | 1.0 times rated voltage, provided by built-in variable frequency power supply | |||
Output voltage measurement range / accuracy | AC 50~280V ±(0.5%×displaying+2 words) | |||
Output current measurement range / accuracy | AC 0.20~30.00A ±(0.5%× displaying +2 words ) | |||
Active power measurement range / accuracy | 30~6000W ±(0.5%× displaying +5 words ) | |||
Power setting alarm range | Upper limit: 3 ~ 6000W , Lower limit: 0 ~ 6000W | |||
Test time range / resolution | 1~300s 1s/step | |||
Low voltage start | ||||
Output voltage | 0.85 times rated voltage provided by the built-in variable frequency power supply | |||
Output voltage measurement range / accuracy | AC 50~280V ±(0.5%× displaying +2words) | |||
Starting current measurement range / accuracy | AC 0.20~30.00A ±(0.5%× displaying +2 words ) | |||
Current setting alarm range | Upper limit:0.20~30.00A Lower limit: 0.00~25.00A | |||
Test time range | 1~300s 1s/step | |||
Communication Interface | 232 485 can Bus TCP / IP interface | |||
External control method | PLC interface, switch signal | |||
System appearance | Size:600W*1840H*600Dmm Height with pulley, alarm light | |||
System standard accessories | Power cord × 1, foot switch × 1, 30A test clamp × 1, test box × 1, power input line × 1, fuse tube × 1 |
Company Details
Business Type:
Manufacturer
Total Annual:
800000-1500000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la... Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la...
Get in touch with us
Leave a Message, we will call you back quickly!