Payment Terms | L/C, T/T |
Supply Ability | 10 Sets Per Month |
Delivery Time | 20 work days |
Packaging Details | Plywood |
Phase Injection Method | Asynchronous or synchronous |
Applied Standard | IEC 61000-4-12 |
Output Impedance | 12Ω, 30Ω |
Short Circuit Current Wave Front (T2) | P1 ≤0.9μs |
Test Content | Oscillatory Waves Immunity test |
Open Circuit Voltage Waveform Front (T1) | Max. 4KV |
Brand Name | Sinuo |
Model Number | SN6616 |
Certification | Calibration Certificate (Cost Additional) |
Place of Origin | China |
View Detail Information
Explore similar products
3M Semi Anechoic Chamber 80MHz-6GHz EMC Test Room EMC Test Systems
IEC 61967-2 Chip Test Integrated Circuit Gigahertz Transverse Electro Magnetic
CISPR25 CISPR 12 3m Anechoic EMC Test Chamber For Automotive ESA
CISPR16-1-1 Gigahertz Transverse Electro Magnetic Cell EMI Test System
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 10 Sets Per Month |
Delivery Time | 20 work days | Packaging Details | Plywood |
Phase Injection Method | Asynchronous or synchronous | Applied Standard | IEC 61000-4-12 |
Output Impedance | 12Ω, 30Ω | Short Circuit Current Wave Front (T2) | P1 ≤0.9μs |
Test Content | Oscillatory Waves Immunity test | Open Circuit Voltage Waveform Front (T1) | Max. 4KV |
Brand Name | Sinuo | Model Number | SN6616 |
Certification | Calibration Certificate (Cost Additional) | Place of Origin | China |
High Light | IEC 61000-4-12 EMC Tester ,Ringing Wave Signal EMC Tester ,Ringing Wave Signal Test Generator |
IEC 61000-4-12 Ringing Wave Signal Test Generator EMC Tester In Low Voltage Power Lines
Product overview:
Ringing signal generators are used to simulate non-repeated damped oscillatory transients in low voltage power, control and signal lines in public and private networks. It provides an ideal standard basis for assessing the immunity of electrical and electronic equipment for domestic, commercial and industrial use.
This ringing signal generator complies with IEC 61000-4-12/ GB/T 17626.12 "Electromagnetic Compatibility (EMC) - Test and Measurement Techniques - Oscillating Wave Immunity Tests" and ANSI-C62-41 "IEEE Guide to Surge Voltages in Low Voltage Alternating Current (AC) Power Supply Circuits", as well as with the requirements of IEC 61009-1, clause 9.19.1, among others.
Transients due to power and control switching (or lightning triggering) can produce ringing wave interference on power, control and signal lines. A common standard has been developed for assessing the immunity of electrical and electronic equipment for domestic, commercial and industrial use.
Technical parameters:
Open Circuit Voltage Oscillation Frequency (1/T) | 100kHz±10% |
Open Circuit Output Voltage (PK1) | (250V~4000V)±10% |
Open Circuit Voltage Waveform Front (T1)(10%~90%) | PK1:0.5μs±30% |
| 40%<(PK2)/(PK1)<110% |
40%<(PK3)/(PK2)<80% | |
40%<(PK4)/(PK3)<80% | |
Short Circuit Current Wave Front (T2) (10%~90%) | P1 ≤0.9μs |
Short Circuit Current (PK1) at 3500V | 292A ± 10% at 12Ω |
Short Circuit Current (PK1) at 3500V | 117A ± 10% at 30Ω |
Adjacent Pulse Interval | 1s~99s |
Number of Pulses | 1~9999 times |
Output Method | Automatic positive and negative polarity switching or alternation |
Output Impedance | 12Ω, 30Ω |
Phase Injection Method | Asynchronous or synchronous (0°~360°) |
Sample Coupling / Decoupling Network | Optional coupling/decoupling network with lightning surge generator |
Structure:
7-inch touchscreen LCD interface with rich features for easy operation and software upgrades
Built-in single-phase 10A (16A) power supply network, two-in-one, compact design.
The EUT output comes with a high-strength panel socket, which makes the connection of test samples more convenient and reliable.
Built-in EUT operating voltage, current monitoring, over-voltage and over-current protection.
Intelligent programme-controlled high-voltage power supply with built-in high-voltage over-voltage, over-current and short-circuit protection.
Intelligent detection of ringing wave output, with voltage error and no output warning function
Self-diagnostic function, can intelligently judge the abnormal output of high voltage and ringing wave.
The main switch adopts imported switches to ensure stable waveforms, strong comparability and long life.
Waveforms are displayed by external oscilloscope (the oscilloscope needs to be prepared by the user)
Company Details
Business Type:
Manufacturer
Total Annual:
800000-1500000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la... Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la...