Delivery Time | Negotiable |
Packaging Details | Sealing wooden drum |
Conductor Type | Flexible or Stranded |
Size | 1.5-800mm2 |
Model | FRC Cable |
Cores | Five |
Warranty | 2 years from B/L date |
Free Sample | Avaliable |
Corporation | shenghua group |
Brand | Sh Cable |
Brand Name | SHANCABLE |
Model Number | WDZAN-YJY 0.6/1kV 5C |
Certification | KEMA,ISO,CE,IEC,PICC |
Place of Origin | SHANGHAI, CHINA |
View Detail Information
Explore similar products
CU / Mica Tape Fire Resistant Cable For Sprinkler / Smoke Control System
Mica Tape Screened Heat Resistant Flexible Cable LSZH PO Insulated 4mm 6mm 10mm
Colorful 450V / 750V Fire Alarm Cables , Heat Resistant Electrical Cable
Copper Conductor Reliable Fire Performance Cable Colored PVC Insulated Sheathed
Product Specification
Delivery Time | Negotiable | Packaging Details | Sealing wooden drum |
Conductor Type | Flexible or Stranded | Size | 1.5-800mm2 |
Model | FRC Cable | Cores | Five |
Warranty | 2 years from B/L date | Free Sample | Avaliable |
Corporation | shenghua group | Brand | Sh Cable |
Brand Name | SHANCABLE | Model Number | WDZAN-YJY 0.6/1kV 5C |
Certification | KEMA,ISO,CE,IEC,PICC | Place of Origin | SHANGHAI, CHINA |
High Light | fire retardant cable ,flame resistant cable |
Fire-Resistant Assemblies XLPE Insulation Frc LSOH 0.6/1kV Power Cable
Construction:
Stranded (RM) bare copper as per IEC60228
Mica Tape for Fire-Proof
XLPE (cross-linked polyethylene) Insulation
Fillers strip, Yarn, or Paper
Non woven Wrapping tape or Flame Retardant
Extruded PVC Inner Covering
Galvanized Steel Tape Armoured
Overall Sheath: polyvinylchloride (PVC) or FR-PVC, PE, LSOH
Application:
Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable.
Technical data:
Test voltage 0.6/1 kV [kV] 3.5 / 5 min.
Temperature range in motion -5°C till +70°C
fixed -20°C till +70°C
Operating temperature short circuit °C 250
Short circuit time max. [sec] 5
Bending radius min. x diameter 15
Flammability standard EN 60332-1-2
Cross section of conductor | Thickness of insulation | Thickness of Sheath | Approx.cable diameter | Max.resistance of conductor at 20 ℃ | Test Voltage(AC) |
mm2 | mm | mm | mm | ohm/km | KV/5min |
5x2.5 | 0.8 | 1.8 | 13.6 | 7.41 | 3.5 |
5x4 | 1.0 | 1.8 | 16.1 | 4.61 | 3.5 |
5x6 | 1.0 | 1.8 | 17.7 | 3.08 | 3.5 |
5x10 | 1.0 | 1.8 | 21.0 | 1.83 | 3.5 |
5x16 | 1.0 | 1.8 | 23.8 | 1.15 | 3.5 |
5x25 | 1.2 | 1.8 | 28.7 | 0.73 | 3.5 |
5x35 | 1.2 | 1.9 | 32.0 | 0.524 | 3.5 |
5x50 | 1.4 | 2.1 | 37.4 | 0.387 | 3.5 |
5x70 | 1.4 | 2.2 | 41.7 | 0.268 | 3.5 |
5x95 | 1.6 | 2.4 | 48.1 | 0.193 | 3.5 |
5x120 | 1.6 | 2.5 | 53.0 | 0.153 | 3.5 |
5x150 | 1.8 | 2.7 | 58.6 | 0.124 | 3.5 |
5x185 | 2.0 | 2.9 | 65.1 | 0.0991 | 3.5 |
5x240 | 2.2 | 3.1 | 72.1 | 0.0754 | 3.5 |
5x300 | 2.4 | 3.4 | 80.1 | 0.060 | 3.5 |
5x400 | 2.6 | 3.6 | 87.0 | 0.0470 | 3.5 |
Main Properties
No. | Test Item | Property | ||
1 | Construction | Listed to the tables | ||
2 | Conductor resistance | Listed to the tables | ||
3 | Test Voltage | A.C 3.5kV 5min | No breaken | |
4 | Machenical Properties before aging | Tensile Strength | Insulation | Min. 12.5N/mm2 |
Sheath | Min. 12.5N/mm2 | |||
Elongation at break | Insulation | Min. 150% | ||
Sheath | Min. 150% | |||
Machenical properties after aging | Tensile Strength | Insulation | 100℃±2℃7days Min. 12.5N/mm2 | |
Sheath | 100℃±2℃7days Min. 12.5N/mm2 | |||
Varying valve of tensile strength | Insulation | 100℃±2℃7days Max. 25% | ||
Sheath | 100℃±2℃7days Max. 25% | |||
Elongation at break | Insulation | 100℃±2℃7days Min.150% | ||
Sheath | 100℃±2℃7days Min.150% | |||
Varying valve of tensile strength | Insulation | 100℃±2℃7days Max. 25% | ||
Sheath | 100℃±2℃7days Max. 25% | |||
5 | Flame retardant property | IEC60332 - 3 | ||
6 | Constant of insulation resistivity | Min at 20℃ | 36.7 | |
Ki MΩ.km | Min at 70℃ | 0.037 |
Standards:
IEC 60502, 60332, 60331
DIN VDE 0276-620
HD 620 S1: 1996
DIN EN 60228 class 2 (construction)
Packing and shipping: We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.
Company Details
Business Type:
Manufacturer
Year Established:
1997
Total Annual:
150000000-200000000
Employee Number:
5000~6000
Ecer Certification:
Verified Supplier
Company Profile Shanghai Shenghua Cable Group Co., LTD., the headquartered in Pudong New Area, Shanghai. As the leading company in cable industry, Shenghua has a large scale of domestic wire and cable manufacturing enterprises including Shanghai Shenghua, Anhui Lvbao, Ji... Company Profile Shanghai Shenghua Cable Group Co., LTD., the headquartered in Pudong New Area, Shanghai. As the leading company in cable industry, Shenghua has a large scale of domestic wire and cable manufacturing enterprises including Shanghai Shenghua, Anhui Lvbao, Ji...
Get in touch with us
Leave a Message, we will call you back quickly!