Payment Terms | L/C, T/T |
Supply Ability | 100KM/Week |
Delivery Time | 10 Days |
Packaging Details | Wooden Drum |
Rated Voltage | 3.6/6KV |
Insulation Material | XLPE |
Warranty | 2 Years |
Conductor | Copper |
Core | 3 |
Armor | Steel tape |
Screen | Semi-conductor |
Corporation | shenghua group |
Brand | Sh Cable |
Brand Name | SHANCABLE |
Model Number | YJV22-3.6/6KV |
Certification | ISO,CE,IEC,TUV,KEMA |
Place of Origin | Shanghai, China |
View Detail Information
Explore similar products
Laying Indoor / Outdoor XLPE Insulated Power Cable , XLPE Insulated PVC Sheathed
0.6/1kV Low Voltage Copper XLPE Insulated Power cable Electrical cable
600/1000V Copper Conductor XLPE Insulated Power cable Electrical cable
Single Core XLPE Insulated Power Cable Copper Conductor with the Metal Screen
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 100KM/Week |
Delivery Time | 10 Days | Packaging Details | Wooden Drum |
Rated Voltage | 3.6/6KV | Insulation Material | XLPE |
Warranty | 2 Years | Conductor | Copper |
Core | 3 | Armor | Steel tape |
Screen | Semi-conductor | Corporation | shenghua group |
Brand | Sh Cable | Brand Name | SHANCABLE |
Model Number | YJV22-3.6/6KV | Certification | ISO,CE,IEC,TUV,KEMA |
Place of Origin | Shanghai, China | ||
High Light | xlpe insulation cable ,xlpe insulated cable |
XLPE Insulated 3.6kV/6kV IEC60502-2 STA MV Electrical Power Cable
Application
Apply to shafts, water and soil, able to bear the larger positive pressure. Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Property
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Construction
Conductor | Compact Stranded Copper Conductor, Class 2 as per IEC 60228 |
Circular solid Copper Conductor, Class 1 as per IEC 60228 | |
Flexible Stranded Copper Conductor, Class 5 as per IEC 60228 | |
Conductor Screen | Semi-conductor |
Insulation | XLPE(Cross-linked polyethylene) |
Insulation Screen | Semi-conductor |
Metalic Shield | Copper Tape Screen or Copper wire & copper tape Shield |
Filler | Fillers strip |
Wrapping Tape | Non woven wrapping tape or lsoh wrapping tape |
Inner Covering | Extruded PVC, or LSOH |
Armour | Steel Tape Armour |
Overall Sheath | PVC, FR-PVC, PE or LSOH |
Specifications
MV(6 to 35kv) Power Cable | |||
Model and Description Uo/U(Um)=3.6/6(7.2), 6/6(7.2), 6/10(12), 8.7/10(12), 8.7/15(17.5), 12/20(24), 18/30(36), 21/35(40.5), 26/35(40.5)kV | No.of Core | Conductor cross-section area(mm2) | |
xlpe insulation | 1 core 3 core | 10 16 25 35 70 95 120 150 185 240 300 400 500 630 sq mm | |
Cu core | Al Core | ||
YJV, N2XSY;PVC sheathed power cable | YJLV, NA2XSY; PVC sheathed power cable | ||
YJV22;steel tape armoured,PVC sheathed power cable | YJLV22;steel tape armoured,PVC sheathed power cable | ||
YJV32,YJV42;steel wire armoured ,PVC sheathed power cable | YJLV32,YJLV42;steel wire armoured ,PVC sheathed power cable | ||
pvc insulation | |||
Cu Core | Al Core | ||
VV(VY);PVC(PE)sheathed power cable | VLV(VLY);PVC(PE)sheathed power cable | ||
VV22(VV23);steel tape armoured,PVC(PE)sheathed power cable | VLV22(VLV23);steel tape armoured,PVC(PE)sheathed power cable | ||
VV32(VV33),VV42(VV43);steel wire armoured ,PVC(PE)sheathed power cable | VLV32(VLV33),VLV42(VLV43);steel wire armoured ,PVC(PE)sheathed power cable |
Technical data
Test voltage | 6 / 10 kV | [kV] | 21 / 5 min. |
12 / 20 kV | [kV] | 42 / 5 min. | |
18 / 30 kV | [kV] | 63 / 5 min. | |
Temperature range | in motion | -20°C till +90°C | |
fixed | -20°C till +90°C | ||
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 15 |
Flammability | standard | EN 50265-2-1 |
Nom. Cross-section of conductor | Strands No./Dia. Of Conductor | Insulation Thickness | Inner Sheath Thickness | Steel Tape Thickness | Sheath Thickness | Approx. O.D. | Approx. Weight | Max. D.C Resistance of Conductor (20 ℃) | Testing Voltage A.C | Current Rating | |
mm2 | pc/mm | mm | mm | mm | mm | (mm) | kg/km | Ω /km | kV/5min | In air (A) | In soil(A) |
3 × 35 | 7/2.52 | 5.5 | 1.8 | 2 × 0.5 | 2.9 | 58.0 | 4840 | 0.524 | 42 | 140 | 155 |
3 × 50 | 10/2.52 | 5.5 | 1.8 | 2 × 0.5 | 3.0 | 61.0 | 5463 | 0.387 | 42 | 165 | 180 |
3 × 70 | 14/2.52 | 5.5 | 2.0 | 2 × 0.5 | 3.1 | 65.0 | 6446 | 0.268 | 42 | 210 | 220 |
3 × 95 | 19/2.52 | 5.5 | 2.0 | 2 × 0.5 | 3.2 | 68.0 | 7457 | 0.193 | 42 | 255 | 265 |
3 × 120 | 24/2.52 | 5.5 | 2.0 | 2 × 0.5 | 3.3 | 71.0 | 8459 | 0.153 | 42 | 290 | 300 |
3 × 150 | 30/2.52 | 5.5 | 2.2 | 2 × 0.5 | 3.4 | 75.0 | 10555 | 0.124 | 42 | 330 | 340 |
3 × 185 | 37/2.52 | 5.5 | 2.2 | 2 × 0.5 | 3.5 | 78.0 | 11925 | 0.0991 | 42 | 375 | 380 |
3 × 240 | 48/2.52 | 5.5 | 2.2 | 2 × 0.8 | 3.7 | 83.0 | 13959 | 0.0754 | 42 | 435 | 435 |
3 × 300 | 61/2.52 | 5.5 | 2.2 | 2 × 0.8 | 3.9 | 88.0 | 16314 | 0.0601 | 42 | 495 | 485 |
3 × 400 | 61/2.97 | 5.5 | 2.3 | 2 × 0.8 | 4.1 | 95.0 | 19032 | 0.047 | 42 | 565 | 520 |
Company Details
Business Type:
Manufacturer
Year Established:
1997
Total Annual:
150000000-200000000
Employee Number:
5000~6000
Ecer Certification:
Verified Supplier
Company Profile Shanghai Shenghua Cable Group Co., LTD., the headquartered in Pudong New Area, Shanghai. As the leading company in cable industry, Shenghua has a large scale of domestic wire and cable manufacturing enterprises including Shanghai Shenghua, Anhui Lvbao, Ji... Company Profile Shanghai Shenghua Cable Group Co., LTD., the headquartered in Pudong New Area, Shanghai. As the leading company in cable industry, Shenghua has a large scale of domestic wire and cable manufacturing enterprises including Shanghai Shenghua, Anhui Lvbao, Ji...
Get in touch with us