China 3051CD2A22A1AB4 Pressure Temperature Transmitter 4-20mA New In Box
China 3051CD2A22A1AB4 Pressure Temperature Transmitter 4-20mA New In Box

  1. China 3051CD2A22A1AB4 Pressure Temperature Transmitter 4-20mA New In Box
  2. China 3051CD2A22A1AB4 Pressure Temperature Transmitter 4-20mA New In Box

3051CD2A22A1AB4 Pressure Temperature Transmitter 4-20mA New In Box

  1. MOQ: 1 ea
  2. Price: Negotiate
  3. Get Latest Price
Payment Terms T/T,PAYONEER
Supply Ability 20EA
Delivery Time 6 WEEKS
Packaging Details In Box
BRAND EMERSON ROSEMOUNT
MODEL 3051CD2A22A1AB4
CATEGORY Coplanar Pressure Transmitters
SUPPLY 4-20mA
Measurement type Differential
Delivery time 4-6 weeks
Brand Name ROSEMOUNT
Model Number 3051CD2A22A1AB4
Place of Origin Singapore
Certification Does not supply

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T,PAYONEER Supply Ability 20EA
Delivery Time 6 WEEKS Packaging Details In Box
BRAND EMERSON ROSEMOUNT MODEL 3051CD2A22A1AB4
CATEGORY Coplanar Pressure Transmitters SUPPLY 4-20mA
Measurement type Differential Delivery time 4-6 weeks
Brand Name ROSEMOUNT Model Number 3051CD2A22A1AB4
Place of Origin Singapore Certification Does not supply
High Light 3051C Pressure Temperature TransmitterDifferential Pressure Temperature Transmitter ODM3051CD2A22A1AB4

3051CD2A22A1AB4 Pressure Transmitters Rosemount 3051C Coplanar Transmitter

 

Product Information Of : 3051CD2A22A1AB4

Brand EMERSON ROSEMOUNT
Model 3051CD2A22A1AB4
SUPPLY

4–20 mA with digital signal based on HART® Protocol

SIZE Does not supply
Weight 5KG

 

   Rosemount 3051C Coplanar Pressure Transmitters are the industry standard for differential, gage, and absolute pressure measurement. The coplanar platform enables seamless integration with manifolds, flow, and level solutions.
Capabilities include:
1) The Loop Integrity Diagnostic continuously monitors the electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).
2) LOI with straightforward menus and built-in configuration buttons (option code M4).
3) Safety certification (option code QT).

 

More options:

MR-J3-10A

MR-J3-10B

MR-J3-20A

MR-J3-20B

MR-J3-40A

MR-J3-40B

MR-J3-60A

MR-J3-60B

MR-J3-70A

MR-J3-70B

MR-J3-100A

MR-J3-100B

MR-J3-200A

MR-J3-200B

MR-J3-350A

MR-J3-350B

MR-J3-500A

MR-J3-500B

MR-J3-700A

MR-J3-700B

 

Rosemount 3051C Pressure Transmitters Information :

Model Transmitter type
3051C Coplanar pressure transmitter  
Measurement type
D Differential
G Gage
A(1) Absolute  
Pressure range
  Differential (Rosemount 3051CD) Gage (Rosemount 3051CG) Absolute (Rosemount 3051CA)  
1

–25 to 25 inH2O (–62,16 to 62,16

mbar)

–25 to 25 inH2O (–62,16 to

62,16 mbar)

0 to 30 psia (0 to 2,06 bar)
2

–250 to 250 inH2O (–621,60 to

621,60 mbar)

–250 to 250 inH2O (–621,60 to

621,60 mbar)

0 to 150 psia (0 to 10,34 bar)
3

–1000 to 1000 inH2O (–2,48 to

2,48 bar)

–393 to 1000 inH2O (–0,97 to

2,48 bar)

0 to 800 psia (0 to 55,15 bar)
4

–300 to 300 psi (–20,68 to 20,68

bar)

–14.2 to 300 psi (–0,97 to 20,68

bar)

0 to 4000 psia (0 to 275,79 bar)
5

–2000 to 2000 psi (–137,89 to

137,89 bar)

–14.2 to 2000 psi (–0,97 to

137,89 bar)

N/A
0(2) –3 to 3 inH2O (-7,46 to 7,46 mbar) N/A N/A  
Transmitter output
A(3) 4–20 mA with digital signal based on HART® Protocol
F FOUNDATION™ Fieldbus Protocol
W(4) PROFIBUS® PA Protocol
X (5) Wireless (requires wireless options and engineered polymer housing)
M(6) Low-power, 1–5 Vdc with digital signal based on HART Protocol  
Materials of construction
  Process flange type Flange material Drain/vent  
2 Coplanar SST SST
3(7) Coplanar Cast C-276 Alloy C-276
4 Coplanar Alloy 400 Alloy 400/K-500
5 Coplanar Plated CS SST
7(7) Coplanar SST Alloy C-276
8(7) Coplanar Plated CS Alloy C-276
0 Alternate process connection
Isolating diaphragm
2(7) 316L SST
3(7) Alloy C-276
4(8) Alloy 400  
5(8) Tantalum (available on Rosemount 3051CD and CG, ranges 2–5 only; not available on Rosemount 3051CA)  
6(8) Gold-plated alloy 400 (use in combination with O-ring option code B)  
7(8) Gold-plated 316 SST  
O-ring  
A Glass-filled PTFE
B Graphite-filled PTFE
Sensor fill fluid
1 Silicone
2(8) Inert (differential and gage only)
Housing material Conduit entry size  
A Aluminum ½–14 NPT
B Aluminum M20 x 1.5
E Aluminum, ultra low copper ½–14 NPT
F Aluminum, ultra low copper M20 x 1.5
J SST ½–14 NPT
K SST M20 x 1.5
P(9) Engineered polymer No conduit entries
D(10) Aluminum  
M(10) SST  
Wireless options(11)
Wireless transmit rate, operating frequency, and protocol
WA3 User Configurable Transmit Rate, 2.4 GHz WirelessHART
Antenna and SmartPower
WP5 Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)
Options
Extended product warranty
WR3 3-year limited warranty
WR5 5-year limited warranty
Plantweb control functionality
A01 FOUNDATION Fieldbus control function block suite
Plantweb diagnostic functionality  
DA0 Loop Integrity HART Diagnostic
D01 FOUNDATION Fieldbus Diagnostics Suite
Alternate flange(12)
H2 Traditional flange, 316 SST, SST drain/vent
H3(7) Traditional flange, alloy C, alloy C-276 drain/vent
H4 Traditional flange, cast alloy 400, alloy 400/K-500 drain/vent
H7(7) Traditional flange, 316 SST, alloy C-276 drain/vent
HJ DIN-compliant traditional flange, SST, 7/16-in. (10 mm) adapter/manifold bolting
FA Level flange, SST, 2-in. (51 mm), ANSI class 150, vertical mount 316 SST drain/vent
FB Level flange, SST, 2-in. (51 mm), ANSI Class 300, vertical mount 316 SST drain/vent
FC Level flange, SST, 3-in. (76 mm), ANSI Class 150, vertical mount 316 SST drain/vent
FD Level flange, SST, 3-in. (76 mm), ANSI Class 300, vertical mount 316 SST drain/vent
FP DIN level flange, SST, DN 50, PN 40, vertical mount 316 SST drain/vent
FQ DIN level flange, SST, DN 80, PN 40, vertical mount 316 SST drain/vent
HK(13) DIN compliant traditional flange, SST, .4 in. (10 mm) adapter/manifold bolting 316 SST  
HL DIN compliant traditional flange, SST, .5 in. (12 mm) adapter/manifold bolting 316 SST  
Manifold assembly(14)
S5 Assemble to Rosemount 305 Integral Manifold
S6 Assemble to Rosemount 304 Manifold or Connection System
Integral mount primary element(13)(14)
S3 Assemble to Rosemount 405 Compact Orifice Plate
S4(15) Assemble to Rosemount Annubar or Rosemount 1195 Integral Orifice
Seal assemblies(14)
S1(16) Assemble to one Rosemount 1199 seal
S2(17) Assemble to two Rosemount 1199 seals
Mounting bracket(18)
B4 Coplanar flange bracket, all SST, 2-in. pipe and panel
B1 Traditional flange bracket, CS, 2-in. pipe
B2 Traditional flange bracket, CS, panel
B3 Traditional flange flat bracket, CS, 2-in. (51 mm) pipe
B7 Traditional flange bracket, B1 with SST bolts
B8 Traditional flange bracket, B2 with SST bolts
B9 Traditional flange bracket, B3 with SST bolts
BA Traditional flange bracket, B1, all SST
BC Traditional flange bracket, B3, all SST
Product certifications
E8 ATEX Flameproof and Dust Certification
I1(19) ATEX Intrinsic Safety and Dust
IA ATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS PA Protocol only
N1 ATEX Type n Certification and Dust
K8 ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)
E4(20) TIIS Flame-proof
E5 FM Explosion-proof, Dust Ignition-Proof
I5(21) FM Intrinsically Safe, Nonincendive
IE FM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocol only
K5 FM Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2
C6 CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
E6 CSA Explosion-proof, Dust Ignition-proof, Division 2
I6(9) CSA Intrinsic Safety
K6 CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)
E7 IECEx Flameproof, Dust Ignition-proof
I7 IECEx Intrinsic Safety
N7 IECEx Type n Certification
K7 IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
E2 INMETRO Flameproof
I2 INMETRO Intrinsic Safety
IB INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
K2 INMETRO Flameproof, Intrinsic Safety

 

 

Good Service in WTL:
> We offer high quality, fast delivery, competitive price for Mitsubishi Servo Motor and Servo Drive.
> Please send your RFQ to get the latest price.
> Normally, we will ship the items in 1-2 weeks after receive the payment.
> We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
> We have a large stock and the prices are variable, so sometimes the prices we post are not accurate.

If needed, please contact us for specific prices.

 

OUR MAIN BRAND:

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Distributor/Wholesaler,Trading Company,Seller

  • Year Established:

    2009

  • Total Annual:

    100000-200000

  • Employee Number:

    15~30

  • Ecer Certification:

    Verified Supplier

         Wisdomlong Technology CO.,LTD locats at the central of China,Shenzhen, Guangdong Province. With rapid development, Wisdomlong serves fields of automation in global markets, Our business covers five continents throughout the world with the basic convicti...          Wisdomlong Technology CO.,LTD locats at the central of China,Shenzhen, Guangdong Province. With rapid development, Wisdomlong serves fields of automation in global markets, Our business covers five continents throughout the world with the basic convicti...

+ Read More

Get in touch with us

  • Reach Us
  • Wisdomlong Technology CO.,LTD
  • 23E BlockB,Lushan Building,Chunfeng Road,Luohu District,Shenzhen,518001,China
  • https://www.servosmotors.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement