Payment Terms | T/T |
Supply Ability | 100pcs per month |
Delivery Time | on request |
Packaging Details | standard carton packing |
Labeling | space for labeling at the front |
Safety Integrity Level (SIL) | SIL 2 |
Degree of protection | IEC 60529:2001 |
Supply Connection | terminals 14+, 15- or power feed module/Power Rail |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
Brand Name | P+F |
Model Number | KFD2-UT2-1 |
Certification | CE |
Place of Origin | Germany |
View Detail Information
Explore similar products
IP20S P+F MART Current Driver KCD2-SCD-Ex1
50mA DC Version P+F Zener Barrier Z787 50mA
P+F 18mA Rotation Speed Monitor KFA6-DWB-Ex1.D
35VDC SIL 2 P+F Current Driver KFD2-CD-Ex1.32
Product Specification
Payment Terms | T/T | Supply Ability | 100pcs per month |
Delivery Time | on request | Packaging Details | standard carton packing |
Labeling | space for labeling at the front | Safety Integrity Level (SIL) | SIL 2 |
Degree of protection | IEC 60529:2001 | Supply Connection | terminals 14+, 15- or power feed module/Power Rail |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
Brand Name | P+F | Model Number | KFD2-UT2-1 |
Certification | CE | Place of Origin | Germany |
High Light | terminals 14 Universal Temperature Converter ,terminals 15 Universal Temperature Converter ,KFD2-UT2-1 |
1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Field device: resistance thermometer, Field device [2]: Thermocouple
Technical Data
General specifications | ||
---|---|---|
Signal type | Analog input | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | terminals 14+, 15- or power feed module/Power Rail | |
Rated voltage | 20 ... 30 V DC | |
Ripple | within the supply tolerance | |
Power dissipation | ≤ 0.98 W | |
Power consumption | max. 0.98 W | |
Interface | ||
Programming interface | programming socket | |
Input | ||
Connection side | field side | |
Connection | terminals 1, 2, 3, 4 | |
RTD | type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995) | |
| Measuring current | approx. 200 µA with RTD |
| Types of measuring | 2-, 3-, 4-wire connection |
| Lead resistance | max. 50 Ω per line |
| Measurement loop monitoring | sensor breakage, sensor short-circuit |
Thermocouples | type B, E, J, K, N, R, S, T (IEC 584-1: 1995) | |
| Cold junction compensation | external and internal |
| Measurement loop monitoring | sensor breakage |
Potentiometer | 0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection) | |
Voltage | selectable within the range -100 ... 100 mV | |
Input resistance | ≥ 1 MΩ (-100 ... 100 mV) | |
Output | ||
Connection side | control side | |
Connection | output I: terminal 7: source (-), sink (+), terminal 8: source (+), terminal 9: sink(-) | |
Output | Analog current output | |
| Current range | 0 ... 20 mA or 4 ... 20 mA |
| Fault signal | downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43) |
| Source | load 0 ... 550 Ω |
| Sink | Voltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V, |
Transfer characteristics | ||
Deviation |
| |
| After calibration | Pt100: ± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection)) |
| Influence of ambient temperature | Pt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔTamb*) |
| Influence of supply voltage | < 0.01 % of span |
| Influence of load | ≤ 0.001 % of output value per 100 Ω |
Reaction time | worst case value (sensor breakage and/or sensor short circuit detection enabled) | |
Galvanic isolation | ||
Input/Other circuits | basic insulation according to IEC 61010-1, rated insulation voltage 300 Veff | |
Output/supply, programming input | functional insulation, rated insulation voltage 50 V AC | |
Indicators/settings | ||
Display elements | LEDs | |
Configuration | via PACTware | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility |
| |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 130 g | |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 | |
| Height | 119 mm |
| Width | 20 mm |
| Depth | 115 mm |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Related Models:
KCD2-SCD-EX1 | KFU8-UFT |
KCD2-STC-EX1.20 | K-HM26-2M-261533 |
KFD2-SR2-Ex1.W.LB | NBB15-U1-E2 |
KFD2-SR2-2.W.SM | NBB1,5-5GM25-E2 |
KFD2-SR2-Ex2.W.SM | NBB1,5-5GM25-E2-V3 |
KFD2-SR2-Ex2.2S | NBB1,5-F79-E0 |
KFD2-SR2-2.2S | NBB1,5-F79-E2 |
KFA6-DWB-EX1.D | NBB15-U1-Z2 |
KFA6-SR2-Ex2.W | NBB5-18GM50-E2-V1 |
KFA6-SR-2.3L.FA | NBB15-30GM30-E2-V1 |
KFA6-ER-1.5 | NBB15-30GM50-A2-V1 |
NBB15-30GM50-E2 | |
KFA6-ER-1.W.LB | NBB15-30GM50-E2-M |
KFA6-ER-2.W.LB | NBB15-30GM50-E2-V1 |
NBB15-30GM50-E2-V1-M | |
KFA6-SR-2.3L.FA | NBB8-18GM30-E2 |
KFA6-STR-1.24.4 | NBB8-18GM30-E2-V1 |
KFD0-CS-Ex1.50P | NBB8-18GM60-A2-V1 |
KFD2-SH-Ex1.T.OP | NJ4-12GK-SN |
KFD2-SL2-EX2.B | NJ5-18GK-N |
KFD2-SR2-EX1.W | NJ5-18GK-N-150 |
KFD2-SR2-Ex2.W | NJ5-18GM-N |
KFD2-STC5-1.2O | NJ8-18GK-N |
KFD2-STC5-Ex1 | RD0-FB-EX4 |
KFD2-STC5-Ex1.H | RD0-TI-Ex8.FF.* |
HIC2031 | Z787.F |
Company Details
Business Type:
Trading Company
Year Established:
2010
Total Annual:
5000000-8000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
SC Automation Limited (hereinafter referred to as SC) was established in 2010 and is a company focused on international trade.We are committed to serving customers worldwide based on the principle of integrity. After years of experience, we have formed good cooperative relationships ... SC Automation Limited (hereinafter referred to as SC) was established in 2010 and is a company focused on international trade.We are committed to serving customers worldwide based on the principle of integrity. After years of experience, we have formed good cooperative relationships ...
Get in touch with us