Payment Terms | T/T |
Supply Ability | 100pcs per month |
Delivery Time | on request |
Packaging Details | standard carton packing |
Degree of protection | IP68 |
Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) |
Dimensions | Length 34mm Diameter 12mm |
Switching function | Normally closed (NC) |
Safety Integrity Level (SIL) | SIL 3 |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
Brand Name | P+F |
Model Number | NJ2-12GK-SN |
Certification | IECEx\ ATEX \UL |
Place of Origin | Germany |
View Detail Information
Explore similar products
IP20S P+F MART Current Driver KCD2-SCD-Ex1
50mA DC Version P+F Zener Barrier Z787 50mA
Terminals 14 15 Universal Temperature Converter KFD2-UT2-1
P+F 18mA Rotation Speed Monitor KFA6-DWB-Ex1.D
Product Specification
Payment Terms | T/T | Supply Ability | 100pcs per month |
Delivery Time | on request | Packaging Details | standard carton packing |
Degree of protection | IP68 | Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) |
Dimensions | Length 34mm Diameter 12mm | Switching function | Normally closed (NC) |
Safety Integrity Level (SIL) | SIL 3 | Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
Brand Name | P+F | Model Number | NJ2-12GK-SN |
Certification | IECEx\ ATEX \UL | Place of Origin | Germany |
High Light | 34mm P+F Sensors ,IP68 P+F Sensors ,NJ2-12GK-SN |
Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017X, Equipment protection level Da: IECEx PTB 11.0092X
Technical Data
General specifications |
||
---|---|---|
Switching function |
Normally closed (NC) |
|
Output type |
NAMUR with safety function |
|
Rated operating distance |
2 mm |
|
Installation |
flush |
|
Assured operating distance |
0 ... 1.62 mm |
|
Reduction factor rAl |
0.4 |
|
Reduction factor rCu |
0.3 |
|
Reduction factor r304 |
0.85 |
|
Safety Integrity Level (SIL) |
up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from P+F, such as KFD2-SH-EX1. |
|
Output type |
2-wire |
|
Nominal ratings |
||
Nominal voltage |
8.2 V (Ri approx. 1 kΩ) |
|
Switching frequency |
0 ... 2000 Hz |
|
Suitable for 2:1 technology |
yes , with reverse polarity protection diode |
|
Current consumption |
|
|
|
Measuring plate not detected |
≥ 3 mA |
|
Measuring plate detected |
≤ 1 mA |
Functional safety related parameters |
||
Safety Integrity Level (SIL) |
SIL 3 |
|
MTTFd |
10660 a |
|
Mission Time (TM) |
20 a |
|
Diagnostic Coverage (DC) |
0 % |
|
Compliance with standards and directives |
||
Standard conformity |
|
|
|
NAMUR |
EN 60947-5-6:2000 |
|
Standards |
EN 60947-5-2:2007 |
Approvals and certificates |
||
IECEx approval |
|
|
|
Equipment protection level Ga |
IECEx PTB 11.0092X |
|
Equipment protection level Gb |
IECEx PTB 11.0092X |
|
Equipment protection level Gc (ec) |
IECEx TUR 21.0017X |
|
Equipment protection level Da |
IECEx PTB 11.0092X |
|
Equipment protection level Dc (tc) |
IECEx TUR 21.0018X |
|
Equipment protection level Mb |
IECEx PTB 11.0092X |
ATEX approval |
|
|
|
Equipment protection level Ga |
PTB 00 ATEX 2049 X |
|
Equipment protection level Gb |
PTB 00 ATEX 2049 X |
|
Equipment protection level Gc (ec) |
TÜV 20 ATEX 8523 X |
|
Equipment protection level Da |
PTB 00 ATEX 2049 X |
|
Equipment protection level Dc (tc) |
TÜV 20 ATEX 8524 X |
UL approval |
cULus Listed, General Purpose |
|
|
Ordinary Location |
E87056 |
|
Hazardous Location |
E501628 |
|
Control drawing |
116-0454 |
CCC approval |
|
|
|
Hazardous Location |
2020322315002308 |
NEPSI approval |
|
|
|
NEPSI certificate |
GYJ16.1392X |
TIIS approval |
on request |
|
Ambient conditions |
||
Ambient temperature |
-40 ... 100 °C (-40 ... 212 °F) |
|
Mechanical specifications |
||
Connection type |
cable |
|
Housing material |
Crastin (PBT), black |
|
Sensing face |
Crastin (PBT), black |
|
Degree of protection |
IP68 |
|
Cable |
|
|
|
Cable diameter |
4.8 mm ± 0.2 mm |
|
Bending radius |
> 10 x cable diameter |
|
Material |
silicone |
|
Core cross section |
0.34 mm2 |
|
Length |
2 m |
Dimensions |
|
|
|
Length |
34 mm |
|
Diameter |
12 mm |
General information |
||
Use in the hazardous area |
see instruction manuals |
Related Part Number:
KFU8-UFT |
K-HM26-2M-261533 |
NBB15-U1-E2 |
NBB1,5-5GM25-E2 |
NBB1,5-5GM25-E2-V3 |
NBB1,5-F79-E0 |
NBB1,5-F79-E2 |
NBB15-U1-Z2 |
NBB5-18GM50-E2-V1 |
NBB15-30GM30-E2-V1 |
NBB15-30GM50-A2-V1 |
NBB15-30GM50-E2 |
NBB15-30GM50-E2-M |
NBB15-30GM50-E2-V1 |
NBB15-30GM50-E2-V1-M |
NBB8-18GM30-E2 |
NBB8-18GM30-E2-V1 |
NBB8-18GM60-A2-V1 |
NJ4-12GK-SN |
NJ5-18GK-N |
NJ5-18GK-N-150 |
NJ5-18GM-N |
NJ8-18GK-N |
RD0-FB-EX4 |
RD0-TI-Ex8.FF.* |
Z787.F |
Company Details
Business Type:
Trading Company
Year Established:
2010
Total Annual:
5000000-8000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
SC Automation Limited (hereinafter referred to as SC) was established in 2010 and is a company focused on international trade.We are committed to serving customers worldwide based on the principle of integrity. After years of experience, we have formed good cooperative relationships ... SC Automation Limited (hereinafter referred to as SC) was established in 2010 and is a company focused on international trade.We are committed to serving customers worldwide based on the principle of integrity. After years of experience, we have formed good cooperative relationships ...
Get in touch with us
Leave a Message, we will call you back quickly!