Payment Terms | T/T |
Supply Ability | 100pcs per month |
Delivery Time | on request |
Packaging Details | standard carton packing |
Safety Integrity Level (SIL) | SIL 2 |
Supply Connection | Power Rail or terminals 9+, 10- |
Degree of protection | IEC 60529:2001 |
Protection against electrical shock | UL 61010-1:2012 |
Display elements | LED |
Electromagnetic compatibility | NE 21:2012 EN 61326-3-2:2008 |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions |
Dimensions | 12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2 |
Brand Name | P+F |
Model Number | KCD2-STC-Ex1.2O |
Certification | BASEEFA 13 ATEX 0077 X |
Place of Origin | Germany |
View Detail Information
Explore similar products
IP20S P+F MART Current Driver KCD2-SCD-Ex1
50mA DC Version P+F Zener Barrier Z787 50mA
Terminals 14 15 Universal Temperature Converter KFD2-UT2-1
P+F 18mA Rotation Speed Monitor KFA6-DWB-Ex1.D
Product Specification
Payment Terms | T/T | Supply Ability | 100pcs per month |
Delivery Time | on request | Packaging Details | standard carton packing |
Safety Integrity Level (SIL) | SIL 2 | Supply Connection | Power Rail or terminals 9+, 10- |
Degree of protection | IEC 60529:2001 | Protection against electrical shock | UL 61010-1:2012 |
Display elements | LED | Electromagnetic compatibility | NE 21:2012 EN 61326-3-2:2008 |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions | Dimensions | 12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2 |
Brand Name | P+F | Model Number | KCD2-STC-Ex1.2O |
Certification | BASEEFA 13 ATEX 0077 X | Place of Origin | Germany |
High Light | SC 3 P+F Sensors ,P+F Sensors KCD2-STC-Ex1.20 ,SMART Transmitter Power Supply |
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC
Technical Data
General specifications | ||
---|---|---|
Signal type | Analog input | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Systematic capability (SC) | SC 3 | |
Supply | ||
Connection | Power Rail or terminals 9+, 10- | |
Rated voltage | 19 ... 30 V DC | |
Ripple | within the supply tolerance | |
Power dissipation | approx. 1.4 W at 20 mA transfer current, 250 Ω in both outputs | |
Power consumption | 2 W | |
Input | ||
Connection side | field side | |
Connection | terminals 1+, 2- (sink); 3+, 4- (source) | |
Input signal | 0/4 ... 20 mA | |
Voltage drop | terminals 3, 4: ≤ 6.1 V at 20 mA | |
Short-circuit current | terminals 1+, 2-: 25 mA | |
Input resistance | terminals 1+, 2-: max. 500 Ω (BRAIN) | |
Available voltage | terminals 1+, 2-: ≥ 16 V at 20 mA , ≥ 18.5 V at 4 mA | |
Output | ||
Connection side | control side | |
Connection | source: terminals 5-, 6+; 7-, 8+ | |
Load | channel 1: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V) | |
Output signal | 0/4 ... 20 mA or 0/1 ... 5 V | |
Ripple | max. 50 µA rms | |
Transfer characteristics | ||
Deviation | Iout < 20 µA (0.1 %); Vout < 10 mV (0.2 %) incl. calibration, linearity, hysteresis and fluctuation of supply voltage, at 20 °C (68 °F), 0/4 ... 20 mA, 0/1 ... 5 V | |
| Influence of ambient temperature | current output: 0.25 µA/K |
Frequency range | field side into the control side: bandwidth with 0.5 Vpp signal 0 ... 6 kHz (-3 dB) | |
Settling time | 6 ms | |
Rise time/fall time | 2 ms | |
Galvanic isolation | ||
Output/power supply | functional insulation, rated insulation voltage 50 V AC | |
Output/Output | functional insulation, rated insulation voltage 50 V AC | |
Indicators/settings | ||
Display elements | LED | |
Control elements | DIP switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility |
| |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 | |
Degree of protection | IEC 60529:2001 | |
Protection against electrical shock | UL 61010-1:2012 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 100 g | |
Dimensions | 12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2 | |
| Height | 124 mm |
| Width | 12.5 mm |
| Depth | 114 mm |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-type examination certificate | BASEEFA 13 ATEX 0077 X | |
| Marking |
|
| Input | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
Supply |
| |
| Maximum safe voltage | 250 V (Attention! The rated voltage can be lower.) |
Equipment | terminals 1+, 2- | |
| Voltage | 25.2 V |
| Voltage | 28.2 V |
| Current | 93 mA |
| Power | 656 mW |
| Internal capacitance | 10 nF |
| Internal inductance | 0 mH |
Equipment | terminals 3+, 4- | |
| Voltage | 30 V |
| Current | 115 mA |
| Power | 700 mW |
| Voltage | 5 V |
| Current | 6.8 mA |
| Power | 1.6 mW |
Output |
| |
| Maximum safe voltage | 250 V (Attention! The rated voltage can be lower.) |
Certificate | BASEEFA 13 ATEX 0078 X | |
| Marking |
|
Galvanic isolation |
| |
| Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Input/power supply | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
Directive conformity |
| |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 |
International approvals | ||
UL approval |
| |
| Control drawing | 116-0380 (cULus) |
IECEx approval |
| |
| IECEx certificate | IECEx BAS 13.0043X |
| IECEx marking | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
Related Part Number:
KCD2-SCD-EX1 |
KCD2-STC-EX1.20 |
KFD2-SR2-Ex1.W.LB |
KFD2-SR2-2.W.SM |
KFD2-SR2-Ex2.W.SM |
KFD2-SR2-Ex2.2S |
KFD2-SR2-2.2S |
KFA6-DWB-EX1.D |
KFA6-SR2-Ex2.W |
KFA6-SR-2.3L.FA |
KFA6-ER-1.5 |
KFA6-ER-1.W.LB |
KFA6-ER-2.W.LB |
KFA6-SR-2.3L.FA |
KFA6-STR-1.24.4 |
KFD0-CS-Ex1.50P |
KFD2-SH-Ex1.T.OP |
KFD2-SL2-EX2.B |
KFD2-SR2-EX1.W |
KFD2-SR2-Ex2.W |
KFD2-STC5-1.2O |
KFD2-STC5-Ex1 |
KFD2-STC5-Ex1.H |
HIC2031 |
Company Details
Business Type:
Trading Company
Year Established:
2010
Total Annual:
5000000-8000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
SC Automation Limited (hereinafter referred to as SC) was established in 2010 and is a company focused on international trade.We are committed to serving customers worldwide based on the principle of integrity. After years of experience, we have formed good cooperative relationships ... SC Automation Limited (hereinafter referred to as SC) was established in 2010 and is a company focused on international trade.We are committed to serving customers worldwide based on the principle of integrity. After years of experience, we have formed good cooperative relationships ...
Get in touch with us
Leave a Message, we will call you back quickly!