Supply Ability | 500 sets per month |
Delivery Time | 3 weeks |
Packaging Details | carton |
Product name | Magnetic flow meter |
Material of wet part | NR / CR / PTFE liner |
MOC of sensor body | 316L / Hastelloy-C, Ti, Ta, Pt100 |
Flow velocity range | 1-15 m/s |
Pressure rating | PN16 | 1.6 Mpa |
Accuracy | +/1 0.5% R |
Pipe Dia. | DN25-DN300 |
Connect port | Flange |
Enclosure protection | IP65 |
Power supply | 100-240 VAC / 18-36 VDC |
Brand Name | Purescience |
Model Number | YE-E250 |
Certification | ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429 |
Place of Origin | China |
View Detail Information
Explore similar products
Ip65 Water Flow Meter Electromagnetic Dn25 - Dn300 With Flanges Port Connection
Flange Connect Magnetic Flow Meter Integrated Transmitter IP68 Enclosure
Flanged Electromagnetic Flow Meters For Conductive Liquids In Pipe
Sewage Treatment Plant Magnetic Flow Meter For Slurry Dn100 Rubber Liner
Product Specification
Supply Ability | 500 sets per month | Delivery Time | 3 weeks |
Packaging Details | carton | Product name | Magnetic flow meter |
Material of wet part | NR / CR / PTFE liner | MOC of sensor body | 316L / Hastelloy-C, Ti, Ta, Pt100 |
Flow velocity range | 1-15 m/s | Pressure rating | PN16 | 1.6 Mpa |
Accuracy | +/1 0.5% R | Pipe Dia. | DN25-DN300 |
Connect port | Flange | Enclosure protection | IP65 |
Power supply | 100-240 VAC / 18-36 VDC | Brand Name | Purescience |
Model Number | YE-E250 | Certification | ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429 |
Place of Origin | China | ||
High Light | liquid flow meter ,ultrasonic water meter |
Mag flowmeter for volumetric flow measurement with low pressure drop for wastewater applications DN300
Accuracy
Pipe Dia (mm) | Velocity (m/s) | Accuracy |
3-20 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout | |
25-600 | 0.1-0.3 | + 0.25% FS |
0.3-1 | + 0.5% Readout | |
1-15 | + 0.3% Readout | |
700-3000 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout |
Grounding
From flow meter housing terminal G to grounding by minimal 1.6mm2 copper cable, resistivity < 10 Ω.
Technical data
Product name | Electromagnetic flowmeter | ||
Product type | Local|compact display | Remote display | Signal converter |
Model | IYF-E | IYF-F | IRT |
Pipe Diameter (mm) | DN10-DN2000 | ||
Power supply | 100-240 VAC / 18-36 VDC | ||
Accuracy | + 0.5% | + 0.5% | + 0.5% |
Power consumption | <6w | <6w | <6w |
Enclosure rating | IP65 | IP68 | IP65 |
Liquid temperature | -25-120℃ | -25-120℃ | -25-120℃ |
Ambient temperature | -25-50℃ | -25-50℃ | -25-50℃ |
Relative humidity | 10-90% | 10-90% | 10-90% |
Meter ratio | 1:100 | 1:100 | 1:100 |
Flow direction | Bi-direction flow | Bi-direction flow | Bi-direction flow |
Communication | RS485 / Bacnet | RS485 / Bacnet | RS485 / Bacnet |
Signal Output | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency |
Description
The flanged electromagnetic flowmeter for use in volumetric measurement of conductive fluid, like municipal
or industrial water and waste water applications in which propeller meters have typically been used in the past.
With no moving parts and electrodes designed to discourage fouling, the IYF magmeter require minimal
maintenance in applications in which debris or sand would impede propeller meters. There is no rotor to stop
turning or bearings to wear out.
It’s externally powered with 100-240VAC or 24 VDC. Low power requirements also make it ideal for solar
and comparable power sources. Rate and total indication is standard, as is a solid state pulse / frequency /
4-20mA output, that allows connection to a data logger.
The display housing can be either integrated or remote. A shielded power/pulse output cable with DIN connection
is included with the meter.
Features
Mounting notice
Model selection
Applicable metering liquid:
Non-applicable metering medial
Notice on the selection of local type and remote type:
Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select
remote type in the following conditions:
I | Model |
|
|
|
|
|
|
| |
| YF | Electromagnetic flowmeter | |||||||
| TF | Turbine | |||||||
| VF | Votex | |||||||
| LX | Vane wheel | |||||||
| T | Ultrasonic | |||||||
|
| E/F display mode | E: compact/local display, F: remote display | ||||||
|
|
| Pipe Dia | Type (mm) | |||||
|
|
| xxxx | 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400, 500, 600, 800, 1000 | |||||
|
|
| Code | Accuracy | |||||
|
|
| 1 | + 0.5% FS | |||||
|
|
| 2 | + 1.0% FS | |||||
|
|
| 3 | + 0.2% FS | |||||
|
|
|
| Code | Type | ||||
|
|
|
| N | Converter: 12 / 24 VDC, pulse output | ||||
|
|
|
| A | Transmitter: 24VDC, 4-20mA outpt | ||||
|
|
|
| B | Intelligent, Lion battery, no local display | ||||
|
|
|
| G | Smart, local display, 4-20mA output | ||||
|
|
|
| C1 | Smart, local display, RS485 | ||||
|
|
|
| C2 | Smart, local display, HART | ||||
|
|
|
|
| Code | Type | |||
|
|
|
|
| S | Carbon steel housing | |||
|
|
|
|
| L | Stainless steel housing | |||
|
|
|
|
| G | High pressure housing | |||
|
|
|
|
| HL | 316L electrode | |||
|
|
|
|
| HTi | Titanium electrode | |||
|
|
|
|
| HTa | Tantlum electrode | |||
|
|
|
|
| HC | Hastelloy-C electrode | |||
|
|
|
|
| L1 | Liquid media | |||
|
|
|
|
| L2 | Gas media | |||
|
|
|
|
| P | Pressure compensation | |||
|
|
|
|
| T | Temperature compensation | |||
|
|
|
|
| PT | Pressure&Temp. Compensation | |||
|
|
|
|
| F | PTFE liner | |||
|
|
|
|
| X | Rubber liner | |||
Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner |
Pipe Diameter, flow volume and product dimension
Dia | Flow volume (m3/h) | Product dimension (mm) | |||||
(mm) | Normal | Min | Max | L | D | H | H1 |
15 | 1.5 | 0.06 | 9.5 | 150 | 95 | 272 | 254 |
20 | 2.5 | 0.11 | 16.9 | 105 | 277 | 254 | |
25 | 3.5 | 0.18 | 26.5 | 115 | 283 | 254 | |
32 | 6 | 0.29 | 43.6 | 140 | 297 | 270 | |
40 | 10 | 0.45 | 67.8 | 150 | 307 | 280 | |
50 | 15 | 0.71 | 106.0 | 200 | 165 | 318 | 294 |
65 | 25 | 1.19 | 179.1 | 185 | 337 | 313 | |
80 | 40 | 1.81 | 271.4 | 200 | 352 | 326 | |
100 | 60 | 2.83 | 424.1 | 250 | 220 | 371 | 344 |
125 | 100 | 4.42 | 665 | 250 | 401 | 372 | |
150 | 135 | 6.36 | 954 | 300 | 285 | 431 | 403 |
200 | 250 | 11.3 | 1696 | 350 | 340 | 486 | 460 |
250 | 375 | 17.66 | 2650 | 400 | 395 | 547 | 511 |
300 | 540 | 25.43 | 3817 | 450 | 445 | 597 | 565 |
350 | 735 | 34.62 | 5195 | 505 | 657 | 620 | |
400 | 960 | 45.22 | 6785 | 500 | 565 | 717 | 675 |
450 | 1200 | 57.23 | 8588 | 550 | 615 | 757 | 727 |
500 | 1500 | 70 | 10602 | 600 | 670< Company Details
Business Type: Manufacturer,Distributor/Wholesaler,Trading Company
Year Established: 2007
Total Annual: 15 million-20 milliion
Employee Number: 100~120
Ecer Certification:
Active Member
Focus on low-carbon energy and environment protection technology, we design and manufacture fluid processing and control products to give our contribution to the sustainable energy develop.
Lots of mega projects have been installed with our products, Shanghai expo center, Shanghai Disne... Focus on low-carbon energy and environment protection technology, we design and manufacture fluid processing and control products to give our contribution to the sustainable energy develop.
Lots of mega projects have been installed with our products, Shanghai expo center, Shanghai Disne... Get in touch with us Leave a Message, we will call you back quickly! |