Payment Terms | L/C, D/P, T/T |
Supply Ability | 2,800,000 sets per year |
Delivery Time | 4-5 weeks |
Packaging Details | unit pack by brown box, pallet |
Product name | Woltman water meter positive displacement |
Port connect | Flange |
Port size | DN50 - DN300 |
Magnetic | Permanent |
Seal | vacuum |
Accuracy | + / - 2% @ cold water |
Operation pressure | 150 psi / 1.0 Mpa |
Standard | ISO4064 , GBT778 , Q/320700JR05-2003 |
Function | Totalizer , flow rate |
Brand Name | Purescience |
Model Number | IXLS300 |
Certification | ISO 4064B, GB/T19001 |
Place of Origin | China |
View Detail Information
Explore similar products
Helix Multi Jet Woltmann Water Meter For Water Distribution And Irrigation DN50
Irrigation Dry Dial Woltman Water Meter For Cold Water Dry Dial Flanged DN250
DN200 CI Woltman Displacement Multi Jet Water Meter Easy Maintenance
Removable Element Woltman Type Water Meter Electromagnetic Simple Operation
Product Specification
Payment Terms | L/C, D/P, T/T | Supply Ability | 2,800,000 sets per year |
Delivery Time | 4-5 weeks | Packaging Details | unit pack by brown box, pallet |
Product name | Woltman water meter positive displacement | Port connect | Flange |
Port size | DN50 - DN300 | Magnetic | Permanent |
Seal | vacuum | Accuracy | + / - 2% @ cold water |
Operation pressure | 150 psi / 1.0 Mpa | Standard | ISO4064 , GBT778 , Q/320700JR05-2003 |
Function | Totalizer , flow rate | Brand Name | Purescience |
Model Number | IXLS300 | Certification | ISO 4064B, GB/T19001 |
Place of Origin | China | ||
High Light | Dry Dial water meter ,multijet water meter |
Woltman Water Flow Meter Multi Jet Water Meter Reed With Positive Displacement
The dry dial woltman water meter can be used for a remote reading transmission system as equipped with a built-in sensor.
Application
--Measuring the volume of cold (hot) water passing through the pipeline
Feature:
--Removable element structure, easy installation and maintenance, register for universal use within this range detachable without Removing the meter from the pipeline;
--Dry-dial, Magnetic drive sensitive action, small pressure loss;
--Vacuum sealed register ensures the dial keep free from fog and Keep the reading clear in a long term service;
--Selected high quality materials for steady & reliable characteristic;
--Technical data conform to international standard ISO 4064.
Working condition
Water temperature: 0.1℃~40℃ ( 0.1℃~90℃ for hot water meter)
Water pressure: ≤1Mpa (1.6MPa for special requirement)
Maximum permissible errors
MAIN TECHNICAL SPECIFICATIONS
Type |
Size (mm) |
Class |
qs Overload Flow |
qp Permanent Flow |
qt Transitional Flow |
qmin Min.Flow |
Min. Reading |
Max. Reading |
m3/h | m3 | |||||||
LXLC-50 | 50 | A | 30 | 15 | 4.5 | 1.2 | 0.0002 | 999,999 |
B | 3.0 | 0.45 | ||||||
LXLC-65 | 65 | A | 50 | 25 | 7.5 | 2.0 | 0.0002 | 999,999 |
B | 5 | 0.75 | ||||||
LXLC-80 | 80 | A | 80 | 40 | 12 | 3.2 | 0.002 | 999,999 |
B | 8.0 | 1.2 | ||||||
LXLC-100 | 100 | A | 120 | 60 | 18 | 4.8 | 0.002 | 999,999 |
B | 12 | 1.8 | ||||||
LXLC-125 | 125 | A | 200 | 100 | 30 | 8 | 0.002 | 999,999 |
B | 20 | 3 | ||||||
LXLC-150 | 150 | A | 300 | 150 | 45 | 12 | 0.002 | 999,999 |
B | 30 | 4.5 | ||||||
LXLC-200 | 200 | A | 500 | 250 | 75 | 20 | 0.002 | 999,999 |
B | 50 | 7.5 | ||||||
LXLC-250 | 250 | A | 800 | 400 | 120 | 32 | 0.002 | 999,999 |
B | 80 | 12 | ||||||
LXLC-300 | 300 | A | 1200 | 600 | 180 | 48 | 0.02 | 9,999,999 |
DIMENSIONS
Type | Size |
L Length |
H Height |
Connecting flange | ||||
φD1 OD |
φD2 Bolt circle diameter |
Connecting Bolts (n-M) |
||||||
mm | ||||||||
LXLC-50 | 50 | 200 | 261 | 165 | 125 | 4-M16 | ||
LXLC-65 | 65 | 200 | 271 | 185 | 145 | 4-M16 | ||
LXLC-80 | 80 | 225 | 279 | 200 | 160 | 8-M16 | ||
LXLC-100 | 100 | 250 | 289 | 220 | 180 | 8-M16 | ||
LXLC-125 | 125 | 250 | 299 | 250 | 210 | 8-M16 | ||
LXLC-150 | 150 | 300 | 319 | 285 | 240 | 8-M20 | ||
LXLC-200 | 200 | 350 | 346 | 340 | 295 | 8-M20(1.0MPa) | ||
12-M20(1.6MPa) | ||||||||
LXLC-250 | 250 | 400 | 434 | 395 | 350 | 12-M20(1.0MPa) | ||
450 | 434 | 405 | 355 | 12-M24(1.6MPa) | ||||
LXLC-300 | 300 | 450 | 459 | 445 | 400 | 12-M20(1.0MPa) | ||
500 | 459 | 460 | 410 | 12-M24(1.6MPa) |
NOTE: The flange dimension conforms to ISO7005-2:1988 standard. Order for products of special requirements is also accepted.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Trading Company
Year Established:
2007
Total Annual:
15 million-20 milliion
Employee Number:
100~120
Ecer Certification:
Active Member
Focus on low-carbon energy and environment protection technology, we design and manufacture fluid processing and control products to give our contribution to the sustainable energy develop. Lots of mega projects have been installed with our products, Shanghai expo center, Shanghai Disne... Focus on low-carbon energy and environment protection technology, we design and manufacture fluid processing and control products to give our contribution to the sustainable energy develop. Lots of mega projects have been installed with our products, Shanghai expo center, Shanghai Disne...