China factories

China factory - Shanghai Xunhui Environment Technology Co., Ltd.

Shanghai Xunhui Environment Technology Co., Ltd.

  • China,Shanghai ,Shanghai
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity
China Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity

  1. China Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity
  2. China Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity
  3. China Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity

Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity

  1. MOQ: 5 sets
  2. Price: USD150-USD900
  3. Get Latest Price
Supply Ability 500 sets per month
Delivery Time 3 weeks
Packaging Details carton
Product name Ultrasonic flowmeters
Type Inline | pipe type
Accuracy + / - 1%FS
Operation Key boards
Output signal 4-20 mA / OCT pulse / relay
Input 3-way 4-20 mA (temperature, pressure and level)
Communication RS485 / Modbus
Power supply 8-36 VDC / 10-30 VAC
Pipe diameter 15 mm - 6000mm
Pipe mount Material weld steel, stainless steel, cast iron, copper / brass, cement pipe, aluminum
Brand Name Purescience
Model Number YE-TUF2000FP
Certification ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 500 sets per month Delivery Time 3 weeks
Packaging Details carton Product name Ultrasonic flowmeters
Type Inline | pipe type Accuracy + / - 1%FS
Operation Key boards Output signal 4-20 mA / OCT pulse / relay
Input 3-way 4-20 mA (temperature, pressure and level) Communication RS485 / Modbus
Power supply 8-36 VDC / 10-30 VAC Pipe diameter 15 mm - 6000mm
Pipe mount Material weld steel, stainless steel, cast iron, copper / brass, cement pipe, aluminum Brand Name Purescience
Model Number YE-TUF2000FP Certification ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Place of Origin China
High Light magnetic flowmeterwater flow meter

Fixed Inline ultrasonic flowmeters by transit time multi-liquid velocity determine for slurry | effluent | sewage

 

General of ultrasonic flow meters

The UFM Ultrasonic flowmeters  can determine the velocity of a fluid flowing in a pipe by sound waves. When it's in no flow conditions, an ultrasonic wave's frequencies are transmitted into a pipe and its reflections from the fluid are the same. When it's under flowing conditions, the frequency of the reflected wave is different due to the Doppler effect. When liquid media moves faster, the frequency shift increases linearly. The transmitter processes signals from the transmitted wave and its reflections to determine the flow rate.

The transit time type ultrasonic flowmeters can give and receive ultrasonic waves between the transducers in both the upstream and downstream in the pipe. While it's under no flow conditions, it takes the same time to travel upstream and downstream between the transducers. While it's under flowing conditions, the upstream wave will travel slower and take more time than the (faster) downstream wave. When the fluid moves faster, the difference between the upstream and downstream times increases. The transmitter processes upstream and downstream times to determine the flow rate.

 

Data sheet

Accuracy                                                           <1%

Flow rate                                                           0 - 10m/s, bi-direction

Pipe diameter                                                    DN32 - DN6000 mm

Liquid temperature                                            -30℃ - 160℃

Liquid type                                                        water, sea water, sewage, effluent, oil, alcohol, any single liquid that can

                                                                           transmit ulstrasonic wave

Pipe material                                                     stainless steel, cast iron, copper, PVC, aluminum, fiber glass steel

Output                                                               one way 4-20mA, one way OCT pulse, one way replay

Input                                                                  three way 4-20mA, PT1000 platinum resistor for heat measurement

Communication                                                RS485, MODBUS

Data storage                                                      SD card

Power supply                                                    DC8-36V / AC85-264V

Protection                                                         IP65 (main body), IP68 (transducer)

Humidity                                                          <85% RH

Ambient temperature                                       -20℃ - 60℃

 

Description:

The ultrasonic flowmeter is available with pipe type, clamp on and other options, it's designed for linear and bi-directional volumetric flow measurement of liquid. The measured flow datas can be output by standard analog or pulse or frequency. Through HMI user friendly operator interface, the unit can be set up for a wide range of applications. Next to actual volumetric flow measurement, the unit can be configured to perform flow totalization ( plus, minus, or sum). Measurement and output of the liquid sonic velocity can be configured too.  

 

Optionally the unit can be set to perform one of the following additional functions:

  • Calculate and output corrected standard volumetric or mass flow using external pressure & temperature inputs
  • Batch function
  • Heat function, combining T1, T2 and volume

Metering Diagram 

Flow measurement                                                Heat measurement

Reference chart

Type

Model

Pipe dia (mm)

Temperature

Dimension (mm)

Clamp on

TS-2

DN15-100

-30-90℃

45x25x32

TM-1

DN50-700

-30-90℃

64x39x44

TL-1

DN300-6000

-30-90℃

97x54x53

Clamp on (high temperature)

TS-2-HT

DN15-100

-30-90℃

45x25x32

TM-1-HT

DN50-700

-30-90℃

64x39x44

TL-1-HT

DN300-6000

-30-90℃

97x54x53

Insertion type

TC-1

DN80-6000

-30-90℃

190x80x55

TC-2(lengthen)

DN80-6000

-30-90℃

335x80x55

Pipe type

G3 (π type)

DN15-25

-30-160℃

 

G2

DN32/DN40

-30-160℃

 

G3

DN50-6000

-30-160℃

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Optional temperature transducer

Specification

Model

Dia

Temp.

Water cut

Accuracy

Clamp-on temp. transducer Pt100

CT-1

>DN50

-40-160℃

No

100+ 0.8℃

Insertion temp. Transducer Pt100

TCT-1

Yes

Insertion temp. Pt100 with pressure

PCT-1

No

Insertion temp.Pt100 for small pipe D

SCT-1

<DN50

Yes

 

 

 

 

 

 

Industries

  • Chemicals
  • Petrochemicals
  • Oil & Gas
  • Heating, Ventilation & Air Conditioning (HVAC)
  • Power Plants
  • Water treatment

Liquid type

  • Metering of cooling water
  • Demineralisedwater
  • Control of batching and blending operations
  • Mass flow measurement
  • Allocation measurement
  • District heating
  • Irrigation
  • Energy measurement

Model Selection

I

Model

 

 

 

 

 

 

 

 

YF

Electromagnetic flowmeter

 

TF

Turbine

 

VF

Votex

 

LX

Vane wheel

 

T

Ultrasonic

 

 

E/F display mode

E: compact/local display, F: remote display

 

 

 

Pipe Dia

Type (mm)

 

 

 

xxxx

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 

400, 500, 600, 800, 1000

 

 

 

Code

Accuracy

 

 

 

1

+ 0.5% FS

 

 

 

2

+ 1.0% FS

 

 

 

3

+ 0.2% FS

 

 

 

 

Code

Type

 

 

 

 

N

Converter: 12 / 24 VDC, pulse output

 

 

 

 

A

Transmitter: 24VDC, 4-20mA outpt

 

 

 

 

B

Intelligent, Lion battery, no local display

 

 

 

 

G

Smart, local display, 4-20mA output

 

 

 

 

C1

Smart, local display, RS485

 

 

 

 

C2

Smart, local display, HART

 

 

 

 

 

Code

Type

 

 

 

 

 

S

Carbon steel housing

 

 

 

 

 

L

Stainless steel housing

 

 

 

 

 

G

High pressure housing

 

 

 

 

 

HL

316L electrode

 

 

 

 

 

HTi

Titanium electrode

 

 

 

 

 

HTa

Tantlum electrode

 

 

 

 

 

HC

Hastelloy-C electrode

 

 

 

 

 

L1

Liquid media

 

 

 

 

 

L2

Gas media

 

 

 

 

 

P

Pressure compensation

 

 

 

 

 

T

Temperature compensation

 

 

 

 

 

PT

Pressure&Temp. Compensation

 

 

 

 

 

F

PTFE liner

 

 

 

 

 

X

Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F, 

Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, 

RS485, 316L electrode, liquid media meter, PTFE liner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Competitive Advantage:

  • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
  • CE approval
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Calibration

Work shop

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Trading Company

  • Year Established:

    2007

  • Total Annual:

    15 million-20 milliion

  • Employee Number:

    100~120

  • Ecer Certification:

    Active Member

Focus on low-carbon energy and environment protection technology, we design and manufacture fluid processing and control products to give our contribution to the sustainable energy develop.   Lots of mega projects have been installed with our products, Shanghai expo center, Shanghai Disne... Focus on low-carbon energy and environment protection technology, we design and manufacture fluid processing and control products to give our contribution to the sustainable energy develop.   Lots of mega projects have been installed with our products, Shanghai expo center, Shanghai Disne...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai Xunhui Environment Technology Co., Ltd.
  • Room 811 Build 143, No. 1399 Husong Road, Shanghai, China
  • https://www.seawaterroplant.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement