Payment Terms | T/T, L/C |
Delivery Time | 25 days |
Packaging Details | Plywood case |
Refrigerant | R404a |
Cooling capacity | 12.29 kw at water outlet -25 ℃ |
Compressor | Piston Compressor |
Condenser | Finned copper tube |
Evaporator | Plate heat exchanger |
Condition | Brandnew |
Name | Glycol water chiller |
Application | Glycol beer chiller, Low temperature chiller for soft drinks containing carbonic acid gas |
Brand Name | ANGES |
Model Number | 25HP |
Place of Origin | China |
View Detail Information
Explore similar products
Air Cooled Low Temperature Chiller 20HP Glycol In Chiller System
8HP Low Temperature Water Cooled Chiller Water Glycol Cooling System
10HP 10 Ton Low Temperature Chiller Portable Glycol In Chilled Water Systems
Air Cooled Low Temperature Chiller 40HP Low Temperature Glycol Chillers
Product Specification
Payment Terms | T/T, L/C | Delivery Time | 25 days |
Packaging Details | Plywood case | Refrigerant | R404a |
Cooling capacity | 12.29 kw at water outlet -25 ℃ | Compressor | Piston Compressor |
Condenser | Finned copper tube | Evaporator | Plate heat exchanger |
Condition | Brandnew | Name | Glycol water chiller |
Application | Glycol beer chiller, Low temperature chiller for soft drinks containing carbonic acid gas | Brand Name | ANGES |
Model Number | 25HP | Place of Origin | China |
High Light | 25HP low temp chiller ,low temp chiller Industrial ,25HP industrial glycol chiller system |
Glycol Chiller Glycol Water Chiller Low Temperature Chiller Glycol Cooling System Low Temperature Cooling Process Chiller
What is a Glycol Chiller?
A glycol chiller is a chilling system that uses a percentage of glycol mixed with water to create chiller circulation liquid temperature far beyond the freezing point of water(temperature below 0 degrees). The antifreeze nature of glycol ensures that the chiller circulation liquid temperature (coolant) remains in a fluid state in order to reach its low cooling points.
The water's freezing point is 0 ℃(32°F), when a glycol-water mixture is altered, the freezing point of the coolant also changes.
From the above analysis, it’s clear that glycol chiller is more suitable for process cooling requires for low-temperature.
Glycol Chiller system
The two types of glycol are ethylene glycol based or propylene glycol based. The industrial glycol chiller water is between 0℃ to -40℃ and the chiller coolant will be transported to the equipment or products that need cooling through chiller pump.
Air-cooled chiller is built-in insulation water tank and water pump, no need to add another cooling tower to heat. It is very easy to install and move. But it has high requirements on the working environment. It is cooled by hot air circulation, so if the ventilation effect of the installation workshop is not good, it will directly affect the refrigeration effect of the chiller.
Application
Industrial glycol water chiller unit is used to cool the hot parts of the equipment, so that the equipment can work normally at low temperature. Used in Beverage filling, spindle cooling, CNC machine tools, grinding miller, reaction system, welding machine, cutting machine and other equipment, temperature adjustment range can be 40 degrees below zero.
Specification
Model |
AC-25L |
|
nominal cooling capacity | kcal/h | 10570 |
kw | 12.29 | |
input power | kw | 22.55 |
power supply | 3PH~380V 50HZ | |
refrigerant | type | R404a |
type of control | expansion valve | |
compressor | type | hermetic scroll(piston) |
power(kw) | 18.75 | |
condenser | type | finned copper tube + low noise outer rotor fan |
evaporator | type | Plate heat exchanger |
chilled fluid flow (m3/h) | 5.94 | |
inlet and outlet pipe diameter (inch) | 2-1/2 | |
pump | power (kw) | 2.2 |
lift(m) | 20 | |
safety protection | compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing | |
dimension | mm | 2000*1130*2000 |
weight | kg | 920 |
The nominal cooling capacity is according to: Inlet chilled fluid temperature: -20℃,outlet chilled fluid temperature: -25℃Note:
Features of glycol cooling system
The proportion of Ethylene Glycol Aqueous Solution of glycol water chiller unit
Operating temperature | Concentration | Density | Specific heat capacity | Heat conductivity | Viscosity | Freezing point |
℃ | % | ×10³ Kg/m³ | KJ/(kg.k) | W/m.k | Pa.s | ℃ |
0 | 25 | 1.03 | 3.834 | 0.511 | 3.8 | -10.6 |
-10 | 35 | 1.063 | 3.561 | 0.4726 | 7.3 | -17.8 |
-20 | 45 | 1.08 | 3.312 | 0.441 | 21 | -26.6 |
-30 | 55 | 1.097 | 2.975 | 0.3725 | 90 | -41.6 |
Company Details
Business Type:
Manufacturer,Importer,Exporter
Year Established:
2004
Total Annual:
12 Million-21 Million
Ecer Certification:
Verified Supplier
Anges Group which headquartered in Shenzhen city is specializes in the design and manufacture industrial process water chiller since 2004. We always adhered to the concept of "Environmental protection, Energy saving, Intelligent and Efficient" and have developed into a well-known supplier ... Anges Group which headquartered in Shenzhen city is specializes in the design and manufacture industrial process water chiller since 2004. We always adhered to the concept of "Environmental protection, Energy saving, Intelligent and Efficient" and have developed into a well-known supplier ...
Get in touch with us
Leave a Message, we will call you back quickly!