Payment Terms | T/T |
Supply Ability | 20 + pcs + per month |
Delivery Time | 15 work days |
Packaging Details | wood box |
name | CCD spectrometers OES |
supply power | Special new platinum infrared light source |
Detector | CCD exported from Europe or Japan |
Feature | detect all elements at one time |
functions | It is used to analysis the elements in the metal sample |
applications | used in metallurgy, foundry, machinery, Metallurgy, Foundry, Mechanical Engineering, Scientific Research, Product Inspection |
Brand Name | WUWAY |
Model Number | WW-CCD1000 |
Place of Origin | China |
View Detail Information
Explore similar products
Ultraviolet UV Spectrophotometer , UV Spectroscopy Machine 753 Type Single Beam
Low Stray Light Optical Emission Spectrometer Excellent Monochromaticity
Ultraviolet UV Spectrophotometer , UV Spectroscopy Machine 753 Type Single Beam
High Accuracy Optical Emission Spectrometer Completely Sealed Analysis
Product Specification
Payment Terms | T/T | Supply Ability | 20 + pcs + per month |
Delivery Time | 15 work days | Packaging Details | wood box |
name | CCD spectrometers OES | supply power | Special new platinum infrared light source |
Detector | CCD exported from Europe or Japan | Feature | detect all elements at one time |
functions | It is used to analysis the elements in the metal sample | applications | used in metallurgy, foundry, machinery, Metallurgy, Foundry, Mechanical Engineering, Scientific Research, Product Inspection |
Brand Name | WUWAY | Model Number | WW-CCD1000 |
Place of Origin | China | ||
High Light | spark emission spectrometer ,uv spectroscopy machine |
Spectrometer optical system:
1. Light room: simple structure, clean light room, stable system, long service life, maintenance free for life (recommended: constant temperature vacuum type, is the mainstream technology adopted by the world spectrometer industry)
2. Light chamber vacuum leakage rate: vacuum pump automatic start and stop function, 24 hours vacuum pump start work must not exceed 4 times, no more than 20 minutes each time
3. Paschen-Longge structure, Roland circular optical system
4. Roland diameter: 400mm
5. Effective wavelength range: 130 – 800 nm
6. Detector: multiple high performance linear array CCD
7. Light room temperature: automatic control constant temperature: 34 ° C ± 0.3 ° C
8. Pixel resolution: 10pm
9. Grating line: 3600 l/mm
10. First-order spectral line dispersion rate: 1.2 nm/mm
11. External incident window for easy cleaning and replacement
12. Excellent drift correction function - thanks to automatic peak finding (accuracy up to 0.1 pixels)
13. Excellent UV sensitivity thanks to new and improved vacuum technology
Description:
Its main use is to analysis the elements in the metal sample. QR-9 series full-spectrum direct-reading spectrometer adopts international standard design and manufacturing technology, adopts full-digital technology, replaces the huge photomultiplier tube (PMT) simulation technology, synchronizes with international spectrometer technology, uses vacuum optical chamber design and full-digital excitation light source, leading CCD detector, high-speed data readout system. The instrument has high performance, low detection limit, long term stability and repeatability.
main feature:
1. The world's advanced second-generation full-spectrum spectrometer technology (digital technology replaces the old-fashioned bulky and bulky photomultiplier tube simulation technology), the channel is no longer restricted
2. Introducing European technology, domestic manufacturer of CCD full spectrum vacuum spectrometer
3. There is no need to change the channel within the base area.
4. Can be upgraded to other bases without adding hardware
5. Excellent data stability, good time consistency can be obtained by analyzing different time segments of the same sample.
6. Small size, light weight, easy to move and install
7. High integration, high reliability, high stability
8. Power saving, material saving and energy consumption are only 50% of ordinary spectrometers.
Digital plasma generator:
1. All-digital plasma spark source technology
2. Efficient thanks to compact design and semiconductor control technology
3. High energy pre-combustion technology (HEPS)
4. The excitation parameters can be customized by the user according to the actual needs through the user interface.
5. Frequency 100 – 1000Hz
6. Current 1-400A
Optimized sample stage:
1. Open sample stage design to meet large sample test requirements
2.4mm sample stage analysis gap
3. "Spray electrode" technology easily handle small samples and complex geometry samples
4. Low argon consumption, standby: no standby flow required
5. Universal Adjustable Sample Adapter
6. Different bases can easily replace the corresponding spark table
7. Optimized impurity discharge system
8. Strong copper sample stage for excellent heat dissipation
Computer and readout system:
1. Brand computer: Lenovo
2. Data output:
3. Data is stored in multiple data formats
4. Can be connected to various standard printing equipment
5. Data can be transmitted remotely via the Internet.
Software system
1.Windows XP operating system
2. Spectrometer operating software
3. Optional data maintenance program
power supply:
1. AC220 V /50 Hz
2. Maximum power 1500 W
3. Average power 1200 W
4. Standby power 70 W
5. 16 A slow blow fuse
Argon requirements:
1. Pure argon gas, 99.999%; Argon gas pressure reducing valve (specially equipped with pressure reducing valve);
2. Air pressure 4-5bar,
3. Copper tube transmission
Detecting matrix | Fe, Al, Cu, Zn, Ti, Ni, Pb, Co, Mg, and their Alloys |
Detecting time | Normally 25s |
Optical Structure | Paschen-Runge mount |
Focal Distance | 400mm |
Wavelength range | 130nm-800nm |
Detector | High resolution CCD Multi detectors |
Electrode | Tungsten Spray discharge electrode |
Analytical Gap | 3.5mm |
Vacuum Degree | Auto control within 6-15 pa |
Pixel resolution | 10pm |
Spectral Line Dispersive Power | 1.2nm/mm |
Spark Source Type | Digital arc and spark source/high energy pre-spark technology(HEPS) |
Spark Frequency | 100-1000HZ |
Discharge Current | max. 380A |
Ignition voltage | >7000V |
Argon Purity | 99.999%, Argon pressure >4Mpa |
Argon consumption | 3.5L/min in sparking mode, 0.4L/min in maintaining mode |
Dimension | 800mm(L)*700mm(W)*470mm(H) |
Weight | About 100kg |
Storage Temperature | 0℃-45℃ |
Operating temperature | 10℃-35℃, 23±2℃ is recommended |
Power | AC220V/50Hz (Customized) |
Power consumption | Excitation: 700W / Stand by:100W |
main applications
It is widely used in metallurgy, foundry, machinery, Metallurgy, Foundry, Mechanical Engineering, Scientific Research, Product Inspection, Automobile, Petrochemical Engineering, Shipbuilding, Electrics, Aerospace, Nuclear Power, Metallic and Nonferrous Metallic Smelting, Processing
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Seller
Year Established:
2002
Total Annual:
3000000-3500000
Employee Number:
100~110
Ecer Certification:
Active Member
Our company mainly provides metal material composition analysis instruments and testing instruments for casting materials; we also provide various accessories and consumables required for equipment and instruments; We provide on-site installation services and free training of operators; If you... Our company mainly provides metal material composition analysis instruments and testing instruments for casting materials; we also provide various accessories and consumables required for equipment and instruments; We provide on-site installation services and free training of operators; If you...
Get in touch with us
Leave a Message, we will call you back quickly!