China EN 149 Mask Bacteria Filtration Efficiency Tester ,BFE PEE Bacteria Testing
China EN 149 Mask Bacteria Filtration Efficiency Tester ,BFE PEE Bacteria Testing

  1. China EN 149 Mask Bacteria Filtration Efficiency Tester ,BFE PEE Bacteria Testing

EN 149 Mask Bacteria Filtration Efficiency Tester ,BFE PEE Bacteria Testing

  1. MOQ: 1 set
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, L/C, Western Union
Supply Ability 100 set per month
Delivery Time 5-7 days
Packaging Details Packaged within wooden case
Model ZL-5065
Aerosol Chamber Specifications (600×85×3)mm
Total number of positive control sampler particles (2200±500) CFU
Negative pressure cabinet ventilation flow ≥5m3/min
Negative pressure cabinet door size (1000×730)mm, (L×W)
Host size (1400×750×2300)mm, (L×W×H)
Working power AC220V±10%,50Hz
Instrument noise <65dB(A)
Total Weight About 350kg
Machine power consumption <1500W
Brand Name ZL
Model Number ZL-5065
Certification ISO
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C, Western Union Supply Ability 100 set per month
Delivery Time 5-7 days Packaging Details Packaged within wooden case
Model ZL-5065 Aerosol Chamber Specifications (600×85×3)mm
Total number of positive control sampler particles (2200±500) CFU Negative pressure cabinet ventilation flow ≥5m3/min
Negative pressure cabinet door size (1000×730)mm, (L×W) Host size (1400×750×2300)mm, (L×W×H)
Working power AC220V±10%,50Hz Instrument noise <65dB(A)
Total Weight About 350kg Machine power consumption <1500W
Brand Name ZL Model Number ZL-5065
Certification ISO Place of Origin China
High Light EN 149 Bacterial Filtration Efficiency TesterBacterial Filtration Efficiency Tester AC220VAC220V Bacterial Filtration Efficiency Test Equipment

EN 149 Mask Bacteria Filtration Efficiency Tester ,BFE PEE Bacteria Testing Machine

1. Product Overview:

 

The Bacterial Filtration Efficiency (BFE) detector is a special instrument for testing the ability of the tested samples (such as masks, etc.) to filter out bacterial particles under specified conditions.

This instrument mainly refers to "Technical Requirements for Medical Surgical Masks" YY0469-2011, Appendix B "Bacterial Filtration Efficiency (BFE) Test Method No. B.1.1.1 Test Instrument", and has carried out innovative improvements, using dual gas paths for simultaneous sampling Compared with the comparison method, the sampling accuracy is improved.

This instrument is suitable for metrological verification departments, third-party testing, textile industry and fiber raw material industry, etc.

 

2. Instrument Features

 

Negative pressure and closed experimental environment to ensure the safety of operators;

Two-way six-level Andersen sampler is used to sample at the same time;

The peristaltic pump is built in the sampling chamber, and the flow rate of the peristaltic pump can be set;

High-performance gas atomizer, the flow rate can be set;

Special microbial aerosol generator, good atomization effect;

Embedded high-speed industrial microcomputer control;

10.4-inch industrial-grade high-brightness color touch screen;

USB interface, support the use of U disk for data transfer;

Support data real-time printing (only for V1.06 and later models);

The cabinet has built-in high-brightness lighting and sterilization UV lamps;

Front switch glass door, easy for experimenters to observe and operate;

Built-in leakage protection switch to protect the safety of instruments and operators;

The inner layer of the cabinet is made of stainless steel as a whole, and the outer layer is spray-coated cold-rolled sheet;

The material between the inner and outer layers has thermal insulation and flame retardant properties;

Detachable bracket, supporting and moving dual-purpose casters.

 

3.Main technical indicators

 

Main parameters Parameter range Resolution Max. allowable error
Left sampling flow 28.3L/min 0.1L/min Better than ±2.5%
Right sampling flow 28.3L/min 0.1L/min Better than ±2.5%
Spray flow (8~10)L/min 0.1L/min Better than ±5.0%
Peristaltic pump flow (0.01~3.0)mL/min 0.001ml/min Better than ±2.5%
Operating temperature (5~30)℃
data storage capacity >100000 groups
HEPA filter characteristics Filtration efficiency for particles above 0.3μm≥99.99%
Aerosol generator mass median diameter Average particle diameter (3.0±0.3)μm, geometric standard deviation≤1.5

Dual-channel 6-stage Anderson sampler

capture particle size (unit: μm)

Class I: >7;

Grade II: 4.7 to 7

Grade III: 3.3~4.7

Grade IV: 2.1 to 3.3

Grade V: 1.1~2.1

Grade VI: 0.6~1.1

Aerosol Chamber Specifications (600×85×3)mm,(Length×Diameter×Thickness)
Total number of positive control sampler particles (2200±500) CFU
Negative pressure cabinet ventilation flow ≥5m3/min
Negative pressure cabinet door size (1000×730)mm, (L×W)
Host size (1400×750×2300)mm, (L×W×H)
Working power AC220V±10%,50Hz
Instrument noise <65dB(A)
Total Weight About 350kg
Machine power consumption <1500W

 

4. Related terms

 

Bacterial Filtration Efficiency (BFE): Under specified conditions, the efficiency of the tested sample to filter out bacteria-containing particles, expressed as a percentage.

Tested samples: masks, textiles and fiber raw materials, etc., are physical barriers to prevent the direct penetration of pathogenic microorganisms, body fluids, particulate matter, etc.

 

5. How it works

 

A certain concentration of bacterial aerosol occurs upstream of the sample to be tested. After entering the aerosol chamber and mixing evenly, the bacterial aerosol enters two parallel gas path sampling systems, one of which is added with the test sample at the upper end of the sampler, and the other end without sample. , as the positive control, by counting the ratio between the value of the positive control and the value of the sample test as the leak rate, the filtration efficiency is obtained.

 

6. Reference Standards

 

YY0469-2011 Appendix B Bacterial Filtration Efficiency (BFE) Test Method Section B.1.1.1 Test Apparatus;

YY/T 0969-2013 Disposable medical masks;

GB19083 standard

 

Machine Certificate:

 

                

 

                

                     

                     Business license                                                              Fame Certificates Wall

 

Factory environment area:

   

                         Company outdoor view                                                          Reception

Sales Team and Technicial Team:

 

      

 

Exhibition:

 

       

 

       

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2014

  • Total Annual:

    1 Million-2.5 Million

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

We,Dongguan Zhongli instrument Technology Co., Ltd. Which Located in Dongguan, Guangdong, China. It is a collection development, research, production and sales of test equipment technology company. Companies with technical support, marketoriented, fundamental human. Have a high level of professio... We,Dongguan Zhongli instrument Technology Co., Ltd. Which Located in Dongguan, Guangdong, China. It is a collection development, research, production and sales of test equipment technology company. Companies with technical support, marketoriented, fundamental human. Have a high level of professio...

+ Read More

Get in touch with us

  • Reach Us
  • Dongguan Zhongli Instrument Technology Co., Ltd.
  • No.62, Xinhe Management of Area, Wanjiang District, Dongguan city, Guangdong province ,China
  • https://www.rubbertestingmachine.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement