China 200TPH Landfill Leachate Reverse Osmosis Treatment Water Filtration Plant
China 200TPH Landfill Leachate Reverse Osmosis Treatment Water Filtration Plant

  1. China 200TPH Landfill Leachate Reverse Osmosis Treatment Water Filtration Plant
  2. China 200TPH Landfill Leachate Reverse Osmosis Treatment Water Filtration Plant

200TPH Landfill Leachate Reverse Osmosis Treatment Water Filtration Plant

  1. MOQ: 1 unit
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time 2-4 weeks
Packaging Details Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping.
RO frame SUS304/Carbon steel (optional)
Power 110KW
Recovery rate 75%
Designed water inlet 135t/h
Outlet flow 200t/h
Desalination rate ≥99.5%
Operating Pressure: 0.8-1.2MPa
Brand Name Jufu
Model Number JFRO-200T
Certification ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Delivery Time 2-4 weeks
Packaging Details Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping. RO frame SUS304/Carbon steel (optional)
Power 110KW Recovery rate 75%
Designed water inlet 135t/h Outlet flow 200t/h
Desalination rate ≥99.5% Operating Pressure: 0.8-1.2MPa
Brand Name Jufu Model Number JFRO-200T
Certification ISO9001 Place of Origin China
High Light Landfill Leachate RO Water Treatment SystemReverse Osmosis Water Filter 200t/HRO Water Filtration Plant

200TPH Landfill leachate reverse osmosis treatment Water Filtration Plant

 

Unique characteristics of RO Water Treatment System

 

1. The single-membrane desalination rate can reach 99%, the desalination rate of the primary reverse osmosis system can generally be stabilized above 90%, and the desalination rate of the secondary reverse osmosis system can generally be stabilized above 98%.

2. Because the reverse osmosis equipment can effectively remove microorganisms, organic substances and inorganic substances such as iron and silicon, the quality of the effluent is higher than other methods.

3. The equipment has small footprint, compact structure, reliable operation and convenient operation.

4. The system is simple, the degree of automation is high, the fault is automatically shut down, and it has the function of automatic protection.

5. The recovery rate can reach more than 70%.

6. Save the chemical consumption cost, labor cost and waste water treatment cost generated by regeneration, and reduce environmental pollution.

 

Technical specifications for RO Water Treatment System

 

Model JFRO-200T
Host Size 7200x2000x2200mm (can be customized)
Power 110KW
Power Supply 220V / 380V / 460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure 1.2-1.5MPa
Recovery Rate 75%
Designed Water Inlet 135t/h
Outlet Flow 100t/h
Desalination Rate ≥99.5%
RO Frame SUS304/Carbon Steel (Optional)
Membrane Size 8040
Membrane Elements DOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes 108
Raw Water Pump CNP/NYP/GRUNDFOS (Optional)
High Pressure Pump CNP/NYP/GRUNDFOS (Optional)
Tank Material SS/FRP(Optional)
Control Valve Manual/Automatic
Control Valve Brand FLECK/RUNXIN
Membrane Housing FRP
Number of Membrane housing 18
Pipe Material U-PVC/ Stainless steel (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reverse osmosis membrane contamination:

 

RO membrane contamination is another important factor that restricts the wide application of RO technology. Membrane contamination not only affects the stable operation and effluent quality of the membrane, but also shortens the service life of the membrane. For membrane contamination, the main methods are:

 

(1) Improve the pretreatment system to ensure the RO system inlet water quality;

(2) RO membrane cleaning, chemical analysis of membrane pollutants, choose the best cleaning agent and cleaning method;

(3) Regularly stop and maintain the RO membrane device.

 

Process flow of RO Water Treatment System

 

Raw water → original water tank → original water pump → multi-media filter (quartz sand filter)→ activated carbon filter → soft water processor → precision filter → high pressure pump → first stage reverse osmosis (RO) device → pure water tank → high pressure pump → second stage reverse osmosis → ultraviolet sterilization device → water point

 

 

The latest development of RO membrane includes inorganic membrane, hybrid membrane and novel organic membrane. Theoretically, inorganic membrane has high ion interception performance, but its high cost and harsh preparation conditions are not conducive to industrial application. Hybrid membrane combines the advantages of organic materials and inorganic materials, which has a good application prospect in improving membrane separation performance and anti-pollution, and has great development potential, which needs further theoretical research. The preparation of new organic membranes is still in the primary stage, and the main purpose is to improve membrane flux and chemical stability, but no breakthrough has been achieved. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAQ:

 

1. What are the inlet water quality requirements for ro water treatment system membrane components?

 

 

Items

NTU SDI Residual chlorine(mg/L) Fe2+(mg/L) TOC(mg/L)
Limits ≤1 ≤5   ≤4 ≤3

 

 

 

 

 

 

2. What is the material of ro water treatment system membrane?

 

Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis

 

Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.

 

 

3. RO water treatment system configuration?

 

First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1

Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.

The arrangement of membrane components can be divided into series and parallel

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2008

  • Total Annual:

    1-10 Mln

  • Employee Number:

    20~100

  • Ecer Certification:

    Active Member

Jufu Water is a Hi-tech enterprise which specialized in integrating Research & Development, Manufacturing, Sales, Engineering installation and Consulting on water treatment and water purification equipment and technologies.   Jufu has strong power on know-how solution providing. The w... Jufu Water is a Hi-tech enterprise which specialized in integrating Research & Development, Manufacturing, Sales, Engineering installation and Consulting on water treatment and water purification equipment and technologies.   Jufu has strong power on know-how solution providing. The w...

+ Read More

Get in touch with us

  • Reach Us
  • Jufu Water Technology Co., Ltd
  • 15F, Block B, FRD International Wealth Center, Fengcheng 12th Road, Weiyang District, Xi’an,Shaanxi, China 710018
  • https://www.rowatertreatmentsystems.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement