Payment Terms | T/T, Western Union |
Supply Ability | 100 Units Per Month |
Delivery Time | 35~45 days |
Packaging Details | Plywood wooden box or stretch film +pallet |
Indoor Unit | Chilled water air handling unit |
Outdoor unit | Air-cooled modular heat pump |
Mounting | Floor standing or ceiling mounting |
Advantage A | Precise temperature control |
Advantage B | Low ambient temperature refrigeration |
Advantage C | Low ring temperature heating |
Advantage D | Intelligent defrosting |
Advantage E | Smart cloud service |
Condition | Fresh air or fresh/return air condition |
Brand Name | Shenglin |
Model Number | SLZK Series |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
HVAC Equipment Air Conditioning Unit In Pharmacy
Clean Room HVAC Equipment Air Handling Unit
Chilled Water AC AHU Unit System In Pharma Precise Temperature Control
Medicine Industry Packaged Hygienic AHU Cooling System Floor Mounted
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 100 Units Per Month |
Delivery Time | 35~45 days | Packaging Details | Plywood wooden box or stretch film +pallet |
Indoor Unit | Chilled water air handling unit | Outdoor unit | Air-cooled modular heat pump |
Mounting | Floor standing or ceiling mounting | Advantage A | Precise temperature control |
Advantage B | Low ambient temperature refrigeration | Advantage C | Low ring temperature heating |
Advantage D | Intelligent defrosting | Advantage E | Smart cloud service |
Condition | Fresh air or fresh/return air condition | Brand Name | Shenglin |
Model Number | SLZK Series | Certification | CE |
Place of Origin | China | ||
High Light | HVAC hygienic air handling units ,ventilation hygienic air handling units ,30000m3/h hygienic AHU |
According to the clean operating room design specifications, the clean air conditioning system must have core technical indicators such as constant temperature, constant humidity, fresh air treatment, air purification, and ensuring the positive and negative pressure difference in the controlled area to achieve the design requirements for controlling the concentration of bacteria and reducing the risk of infection. Clean air conditioners have multiple functions such as air purification, transportation, cooling, dehumidification, humidification, heating, heat recovery, and intelligent control, providing users with clean environment system solutions suitable for different purification levels and different working conditions.
Unit quick selection table (air volume)
Model | Nominal air volume m³/h | Windward area of coil㎡ | Wind speed of the coil(m/s) | |||||
2.00 | 2.25 | 2.50 | 2.75 | 3.00 | 3.25 | |||
m³/h | ||||||||
SLZK015W | 1500 | 0.16 | 1152 | 1296 | 1440 | 1584 | 1728 | 1872 |
SLZK018W | 1800 | 0.2 | 1440 | 1620 | 1800 | 1980 | 2160 | 2340 |
SLZK022W | 2200 | 0.24 | 1728 | 1944 | 2160 | 2376 | 2592 | 2808 |
SLZK032W | 3200 | 0.35 | 2520 | 2835 | 3150 | 3465 | 3780 | 4095 |
SLZK038W | 3800 | 0.42 | 3024 | 3402 | 3780 | 4158 | 4536 | 4914 |
SLZK050W | 5000 | 0.56 | 4032 | 4536 | 5040 | 5544 | 6048 | 6552 |
SLZK063W | 6300 | 0.7 | 5040 | 5670 | 6300 | 6930 | 7560 | 8190 |
SLZK072W | 7200 | 0.8 | 5760 | 6480 | 7200 | 7920 | 8640 | 9360 |
SLZK095W | 9500 | 1.04 | 7488 | 8424 | 9360 | 10296 | 11232 | 12168 |
SLZK120W | 12000 | 1.3 | 9360 | 10530 | 11700 | 12870 | 14040 | 15210 |
SLZK150W | 15000 | 1.69 | 12168 | 13689 | 15210 | 16731 | 18252 | 19773 |
SLZK180W | 18000 | 2.08 | 14976 | 16848 | 18720 | 20592 | 22464 | 24336 |
SLZK230W | 23000 | 2.56 | 18432 | 20736 | 23040 | 25344 | 27648 | 29952 |
SLZK270W | 27000 | 3.04 | 21888 | 24624 | 27360 | 30096 | 32832 | 35568 |
SLZK320W | 32000 | 3.61 | 25992 | 29241 | 32490 | 35739 | 38988 | 42237 |
SLZK370W | 37000 | 4.18 | 30096 | 33858 | 37620 | 41382 | 45144 | 48906 |
SLZK430W | 43000 | 4.75 | 34200 | 38475 | 42750 | 47025 | 51300 | 55575 |
SLZK500W | 50000 | 5.5 | 39600 | 44550 | 49500 | 54450 | 59400 | 64350 |
SLZK550W | 55000 | 6.16 | 44352 | 49896 | 55440 | 60984 | 66528 | 72072 |
SLZK630W | 63000 | 7 | 50400 | 56700 | 63000 | 69300 | 75600 | 81900 |
SLZK700W | 70000 | 7.84 | 56448 | 63504 | 70560 | 77616 | 84672 | 91728 |
SLZK760W | 76000 | 8.5 | 61200 | 68850 | 76500 | 84150 | 91800 | 99450 |
SLZK850W | 85000 | 9.52 | 68544 | 77112 | 85680 | 94248 | 102816 | 111384 |
SLZK930W | 93000 | 10.36 | 74592 | 83916 | 93240 | 102564 | 111888 | 121212 |
SLZK1000W | 100000 | 11.47 | 82584 | 92907 | 103230 | 113553 | 123876 | 134199 |
SLZK1100W | 110000 | 12.58 | 90576 | 101898 | 113220 | 124542 | 135864 | 147186 |
Note: 1. It is recommended to add a water baffle if the wind speed exceeds 2.75m/s.
Unit quick selection table (cooling capacity of coil section under return air condition)
Model | Nominal air volume m³/h | 4 rows | 6 rows | 8 rows | |||
Cooling capacity | Water volume | Cooling capacity | Water volume | Cooling capacity | Water volume | ||
kW | m³/h | kW | m³/h | kW | m³/h | ||
SLZK015W | 1500 | 8.2 | 1.4 | 10.9 | 1.87 | 13.2 | 2.27 |
SLZK018W | 1800 | 10.2 | 1.8 | 13.6 | 2.34 | 16.5 | 2.84 |
SLZK022W | 2200 | 12.6 | 2.2 | 16.4 | 2.82 | 19.8 | 3.41 |
SLZK032W | 3200 | 17.8 | 3.1 | 23.8 | 4.09 | 28.8 | 4.95 |
SLZK038W | 3800 | 21.5 | 3.7 | 28.6 | 4.92 | 34.6 | 5.95 |
SLZK050W | 5000 | 28.7 | 4.9 | 38.1 | 6.55 | 46.2 | 7.95 |
SLZK063W | 6300 | 35.8 | 6.2 | 47.8 | 8.22 | 57.5 | 9.89 |
SLZK072W | 7200 | 41.1 | 7.1 | 54.6 | 9.39 | 66.1 | 11.37 |
SLZK095W | 9500 | 53.3 | 9.2 | 70.8 | 12.18 | 85.6 | 14.72 |
SLZK120W | 12000 | 66.7 | 11.5 | 88.6 | 15.24 | 107.1 | 18.42 |
SLZK150W | 15000 | 86.6 | 14.9 | 115.3 | 19.83 | 138.6 | 23.84 |
SLZK180W | 18000 | 106.5 | 18.3 | 141.8 | 24.39 | 170.3 | 29.29 |
SLZK230W | 23000 | 131.2 | 22.6 | 172.9 | 29.74 | 210.5 | 36.21 |
SLZK270W | 27000 | 155.8 | 26.8 | 206.8 | 35.57 | 248.6 | 42.76 |
SLZK320W | 32000 | 185.1 | 31.8 | 245.2 | 42.17 | 296.5 | 51.00 |
SLZK370W | 37000 | 214.2 | 36.8 | 285.1 | 49.04 | 341.8 | 58.79 |
SLZK430W | 43000 | 243.3 | 41.8 | 323.6 | 55.66 | 385.6 | 66.32 |
SLZK500W | 50000 | 281.5 | 48.4 | 374.5 | 64.41 | 450.3 | 77.45 |
SLZK550W | 55000 | 315.7 | 54.3 | 419.3 | 72.12 | 500.4 | 86.07 |
SLZK630W | 63000 | 358.6 | 61.7 | 476.5 | 81.96 | 560.4 | 96.39 |
SLZK700W | 70000 | 400.5 | 68.9 | 534.1 | 91.87 | 640.5 | 110.17 |
SLZK760W | 76000 | 432.6 | 74.4 | 578.2 | 99.45 | 690.5 | 118.77 |
SLZK850W | 85000 | 482.5 | 83.0 | 645.8 | 111.08 | 765.8 | 131.72 |
SLZK930W | 93000 | 520.6 | 89.5 | 702.3 | 120.80 | 830.5 | 142.85 |
SLZK1000W | 100000 | 576.1 | 99.1 | 778.4 | 133.88 | 940.8 | 161.82 |
SLZK1100W | 110000 | 630.6 | 108.5 | 850.6 | 146.30 | 970.5 | 166.93 |
Note:
1. The inlet temperature of chilled water is 7°C, and the outlet temperature is 12°C;
2. Return air condition: inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃;
3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.
Unit quick selection table(cooling capacity of coil section under fresh air condition)
Model | Nominal air volume m³/h | 4 rows | 6 rows | 8 rows | |||
Cooling capacity | Water volume | Cooling capacity | Water volume | Cooling capacity | Water volume | ||
kW | m³/h | kW | m³/h | kW | m³/h | ||
SLZK015W | 1500 | 18.9 | 3.3 | 23.5 | 4.04 | 28.1 | 4.83 |
SLZK018W | 1800 | 23.5 | 4.0 | 29.4 | 5.06 | 35.1 | 6.04 |
SLZK022W | 2200 | 28.3 | 4.9 | 35.3 | 6.07 | 42.2 | 7.25 |
SLZK032W | 3200 | 41.3 | 7.1 | 51.4 | 8.84 | 61.5 | 10.57 |
SLZK038W | 3800 | 49.5 | 8.5 | 61.7 | 10.61 | 73.8 | 12.69 |
SLZK050W | 5000 | 66.2 | 11.4 | 82.3 | 14.15 | 98.4 | 16.92 |
SLZK063W | 6300 | 82.3 | 14.2 | 102.8 | 17.68 | 122.9 | 21.15 |
SLZK072W | 7200 | 94.5 | 16.3 | 117.5 | 20.21 | 140.5 | 24.17 |
SLZK095W | 9500 | 122.9 | 21.1 | 152.8 | 26.27 | 182.7 | 31.42 |
SLZK120W | 12000 | 153.2 | 26.4 | 190.9 | 32.84 | 228.3 | 39.27 |
SLZK150W | 15000 | 195.6 | 33.6 | 248.2 | 42.69 | 296.8 | 51.05 |
SLZK180W | 18000 | 245.6 | 42.2 | 305.5 | 52.55 | 365.3 | 62.83 |
SLZK230W | 23000 | 302.1 | 52.0 | 376.0 | 64.67 | 449.6 | 77.33 |
SLZK270W | 27000 | 358.7 | 61.7 | 446.5 | 76.80 | 533.9 | 91.83 |
SLZK320W | 32000 | 426.1 | 73.3 | 530.2 | 91.20 | 634.0 | 109.05 |
SLZK370W | 37000 | 492.8 | 84.8 | 613.9 | 105.60 | 734.1 | 126.27 |
SLZK430W | 43000 | 560.8 | 96.5 | 697.7 | 120.00 | 834.2 | 143.49 |
SLZK500W | 50000 | 648.9 | 111.6 | 807.8 | 138.94 | 965.9 | 166.14 |
SLZK550W | 55000 | 727.6 | 125.1 | 904.8 | 155.62 | 1081.9 | 186.08 |
SLZK630W | 63000 | 826.4 | 142.1 | 1028.1 | 176.84 | 1229.4 | 211.45 |
SLZK700W | 70000 | 924.8 | 159.1 | 1151.5 | 198.06 | 1376.9 | 236.83 |
SLZK760W | 76000 | 1005.4 | 172.9 | 1248.4 | 214.73 | 1492.8 | 256.76 |
SLZK850W | 85000 | 1124.3 | 193.4 | 1398.3 | 240.50 | 1672.0 | 287.58 |
SLZK930W | 93000 | 1200.6 | 206.5 | 1514.6 | 260.51 | 1812.4 | 311.73 |
SLZK1000W | 100000 | 1320.6 | 227.1 | 1671.4 | 287.48 | 2010.3 | 345.77 |
SLZK1100W | 110000 | 1450.7 | 249.5 | 1825.7 | 314.02 | 2186.5 | 376.08 |
Note:
1. The inlet temperature of chilled water is 7℃, and the outlet temperature is 12℃;
2. Fresh air conditions: inlet air dry bulb temperature 35℃, wet bulb temperature 28℃;
3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.
Unit quick selection table(hot water coil heating capacity)
Model | Nominal air volume m³/h | Return air condition | Fresh air condition | ||||
2 rows | 3 rows | 4 rows | 2 rows | 3 rows | 4 rows | ||
heating capacity | heating capacity | heating capacity | heating capacity | heating capacity | heating capacity | ||
kW | kW | kW | kW | kW | kW | ||
SLZK015W | 1500 | 9.4 | 12.5 | 14.8 | 11.1 | 15.1 | 18.1 |
SLZK018W | 1800 | 11.8 | 15.6 | 18.5 | 13.9 | 18.9 | 22.6 |
SLZK022W | 2200 | 14.1 | 18.8 | 22.2 | 16.7 | 22.7 | 27.2 |
SLZK032W | 3200 | 20.6 | 27.3 | 32.4 | 24.3 | 33.0 | 39.6 |
SLZK038W | 3800 | 24.7 | 32.8 | 38.9 | 29.1 | 39.6 | 47.5 |
SLZK050W | 5000 | 32.9 | 43.8 | 51.8 | 38.9 | 52.9 | 63.4 |
SLZK063W | 6300 | 41.1 | 54.7 | 64.8 | 48.6 | 66.1 | 79.2 |
SLZK072W | 7200 | 47.0 | 62.5 | 74.0 | 55.5 | 75.5 | 90.5 |
SLZK095W | 9500 | 61.1 | 81.3 | 96.2 | 72.2 | 98.2 | 117.7 |
SLZK120W | 12000 | 76.4 | 101.6 | 120.3 | 90.2 | 122.7 | 147.1 |
SLZK150W | 15000 | 99.3 | 132.0 | 156.3 | 117.2 | 159.5 | 191.2 |
SLZK180W | 18000 | 122.2 | 162.5 | 192.4 | 144.3 | 196.3 | 235.3 |
SLZK230W | 23000 | 150.4 | 200.0 | 236.8 | 177.6 | 241.6 | 289.6 |
SLZK270W | 27000 | 178.6 | 237.5 | 281.2 | 210.9 | 286.9 | 343.9 |
SLZK320W | 32000 | 212.1 | 282.0 | 333.9 | 250.4 | 340.7 | 408.4 |
SLZK370W | 37000 | 245.6 | 326.6 | 386.7 | 290.0 | 394.5 | 472.9 |
SLZK430W | 43000 | 279.1 | 371.1 | 439.4 | 329.5 | 448.3 | 537.3 |
SLZK500W | 50000 | 323.1 | 429.7 | 508.8 | 381.6 | 519.1 | 622.2 |
SLZK550W | 55000 | 361.9 | 481.3 | 569.8 | 427.4 | 581.4 | 696.9 |
SLZK630W | 63000 | 411.3 | 546.9 | 647.5 | 485.6 | 660.6 | 791.9 |
SLZK700W | 70000 | 460.6 | 612.5 | 725.2 | 543.9 | 739.9 | 886.9 |
SLZK760W | 76000 | 499.4 | 664.1 | 786.3 | 589.7 | 802.2 | 961.6 |
SLZK850W | 85000 | 559.3 | 743.8 | 880.6 | 660.5 | 898.5 | 1077.0 |
SLZK930W | 93000 | 608.7 | 809.4 | 958.3 | 718.7 | 977.7 | 1172.0 |
SLZK1000W | 100000 | 673.9 | 896.1 | 1061.0 | 795.7 | 1082.5 | 1297.5 |
SLZK1100W | 110000 | 739.1 | 982.8 | 1163.7 | 872.7 | 1187.2 | 1423.1 |
Note:
1. The inlet temperature of hot water is 60°C, and the outlet temperature is 50°C;
2. Return air condition: inlet air dry bulb temperature 15℃; fresh air condition: inlet air dry bulb temperature 7℃;
3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.
Company Details
Business Type:
Manufacturer
Year Established:
2009
Employee Number:
>100
Ecer Certification:
Active Member
Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ... Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ...
Get in touch with us
Leave a Message, we will call you back quickly!