Payment Terms | T/T, Western Union |
Supply Ability | 1000 PCS/month |
Delivery Time | 15~20 days |
Packaging Details | Plywood box and with dust/moisture-proof film |
COP | 4 |
Compressor | Panasonic or Copeland brand |
Heat exchanger type | One fin type, one coil type |
Application | House, Appartment, School, Hospital, Villa |
Supply power | 220/1PH/50Hz |
Refrigerant | R22/R417A/R404A/R407C/R410A |
Working ambient temperature | -15 ° C~ 45 ° C |
Warranty | 1 Year |
Installation | Freestanding |
Heating capacity range | 15~84kW |
Water outlet temp. | 55° C |
Max water outlet temp. | 60° C |
Brand Name | Shenglin |
Model Number | MD series |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
3.2kw Swimming Pool Inverter Heat Pump , Low Temperature Heat Pump DN25
Hot Water 52KW Rooftop Heat Pump High Temperature Rooftop Hvac Units
5HP 21kW Air Source Heat Pumps , Air Temp Heat Pump 5000L H
EVI Scroll DKFXR Air To Water Heat Pump 60KW Domestic For Commercial Use
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 1000 PCS/month |
Delivery Time | 15~20 days | Packaging Details | Plywood box and with dust/moisture-proof film |
COP | 4 | Compressor | Panasonic or Copeland brand |
Heat exchanger type | One fin type, one coil type | Application | House, Appartment, School, Hospital, Villa |
Supply power | 220/1PH/50Hz | Refrigerant | R22/R417A/R404A/R407C/R410A |
Working ambient temperature | -15 ° C~ 45 ° C | Warranty | 1 Year |
Installation | Freestanding | Heating capacity range | 15~84kW |
Water outlet temp. | 55° C | Max water outlet temp. | 60° C |
Brand Name | Shenglin | Model Number | MD series |
Certification | CE | Place of Origin | China |
High Light | 15kw Air Source Heat Pumps ,dn25 Air Source Heat Pumps ,dn25 air ground source heat pumps |
Air To Water Heat Pump For Hotel And Villa
Technical paramater:
Air source heat pump | MODEL | Unit | MD40D | ||
Average heating input power | KW | 3.78 | |||
Rated heating capacity | KW | 15 | |||
Hot water supply | L/h | 350 | |||
Rated heating input current | A | 9 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 55 | |||
Dimension | W*D*H | mm | 1120*490*1270 | ||
Packing size | W*D*H | mm | 1200*520*1425 | ||
Unit weight | KG | 160 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 4000L/h | |||
Water pressure down | Kpa | 55 | |||
Pipe size | DN | 25 | |||
Air source heat pump | MODEL | Unit | MD50D | ||
Average heating input power | KW | 4.6 | |||
Rated heating capacity | KW | 18.6 | |||
Hot water supply | L/h | 400 | |||
Rated heating input current | A | 9 | |||
Max outlet water temp | C | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 55 | |||
Dimension | W*D*H | mm | 1120*490*1270 | ||
Packing size | W*D*H | mm | 1200*520*1425 | ||
Unit weight | KG | 170 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 5000L/h | |||
Water pressure down | Kpa | 45 | |||
Pipe size | DN | 25 | |||
Article | Parameter | ||||
Air source heat pump | MODEL | Unit | MD60D | ||
Average heating input power | KW | 5.2 | |||
Rated heating capacity | KW | 21 | |||
Hot water supply | L/h | 500 | |||
Rated heating input current | A | 12 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380/50 | |||
Noise | Db(a) | 60 | |||
Dimension | W*D*H | mm | 1120*490*1270 | ||
Packing size | W*D*H | mm | 1200*520*1425 | ||
Unit weight | KG | 180 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 6000L/h | |||
Water pressure down | Kpa | 48 | |||
Pipe size | DN | 25 | |||
Air source heat pump | MODEL | Unit | MD100D | ||
Average heating input power | KW | 9.2 | |||
Rated heating capacity | KW | 36 | |||
Hot water supply | L/h | 800 | |||
Rated heating input current | A | 18 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 60 | |||
Dimension | W*D*H | mm | 1450×760×1060 | ||
Packing size | W*D*H | mm | 1520*800*1230 | ||
Unit weight | KG | 310 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 10000L/h | |||
Water pressure down | Kpa | 54 | |||
Pipe size | DN | 32 | |||
Air source heat pump | MODEL | Unit | MD150D | ||
Average heating input power | KW | 11 | |||
Rated heating capacity | KW | 42 | |||
Hot water supply | L/h | 1000 | |||
Rated heating input current | A | 24 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 60 | |||
Dimension | W*D*H | mm | 1450×760×1060 | ||
Packing size | W*D*H | mm | 1520*800*1230 | ||
Unit weight | KG | 340 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 12000L/h | |||
Water pressure down | Kpa | 54 | |||
Pipe size | DN | 32 | |||
Article | Parameter | ||||
Air source heat pump | MODEL | Unit | MD200D | ||
Average heating input power | KW | 19 | |||
Rated heating capacity | KW | 72 | |||
Hot water supply | L/h | 1600 | |||
Rated heating input current | A | 35 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 70 | |||
Dimension | W*D*H | mm | 2040×1100×2000 | ||
Packing size | W*D*H | mm | 2080×1150×2130 | ||
Unit weight | KG | 650 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 20000L/h | |||
Water pressure down | Kpa | 60 | |||
Pipe size | DN | 50 | |||
Air source heat pump | MODEL | Unit | MD300D | ||
Average heating input power | KW | 22 | |||
Rated heating capacity | KW | 84 | |||
Hot water supply | L/h | 2000 | |||
Rated heating input current | A | 40 | |||
Max outlet water temp | ℃ | 60 | |||
Power | V/Hz | 380V/50 | |||
Noise | Db(a) | 70 | |||
Dimension | W*D*H | mm | 2040×1100×2000 | ||
Packing size | W*D*H | mm | 2080×1150×2130 | ||
Unit weight | KG | 750 | |||
Working air temp range | (-15℃)—45℃ | ||||
compressor | Type | Copeland | |||
Air source heat exchanger | Type | Finned heat exchange | |||
Fan Type | axial flow fan | ||||
Hot water side heat exchange | Type | Coil heat exchanger | |||
Water flow | L/H | 25000L/h | |||
Water pressure down | Kpa | 60 | |||
Pipe size | DN | 50 |
Parts:
![]() | Heat exchanger type A: fin heat exchanger |
![]() | Heat exchanger type B: coil heat exchanger |
![]() | Heat exchanger type C: plate heat exchanger |
![]() | Electric expansion valve |
![]() | Expansion valve |
![]() | Relay |
![]() | Senssor connector |
![]() | Liquid, gas separator |
![]() | Sensor |
![]() | Thermal expansion valve |
![]() | Control panel |
Simple installation diagram for air source:
Why choose us?
A. Technical service
1. We calculate the capacity and recommend the best models.
2. We supply you the professional refrigeration technical support and electronic technical support for your installation,
debugging and operation.
3. We supply the spare parts and technical support in and after the warranty time.
4. We supply the training course to your workers at our factory if you need, we can also offer site training.
5. We welcome you to be our partner.
B. After-sales service
1. Technical support for your installation, operation and maintenance.
2. Standard warranty time: One year warranty for heat pumps
You can also pay for extended warranty or we can renegotiate the longer warranty period.
3. Spare parts and technical support at most economic prices after the warranty.
C. Certificate we have got :
1. CE
Company Details
Business Type:
Manufacturer
Year Established:
2009
Employee Number:
>100
Ecer Certification:
Active Member
Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ... Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ...
Get in touch with us
Leave a Message, we will call you back quickly!